Amasly AMA-RD06 Adjustable LED Street Light | up to 180 lm/W
Inhalt
Kontakt
- E-Mail: sales01@amasly.com
- Mobil: +86 13732643699
The Amasly AMA-RD06 is a die-cast aluminium LED street light for roads, residential streets, courtyards and squares. It comes in four builds, 50W, 100W, 150W and 200W, all rated 170–180 lm/W on a 90–305V input.
Two details separate it from a standard road luminaire. The head sits on a 90° rotating die-cast bracket with an inclinometer built into the housing, and the driver has its own power box that opens with a buckle instead of a screwdriver. Both matter to the crew on the pole, not only to the spec sheet.
The rest of the build is what a road lighting specifier expects: ADC12 body, 3030 LED chips on a thermally conductive aluminium PCB, tempered glass over a UV-stabilised PC lens, a 10 kV or 20 kV surge module, IK09 impact rating, and CE and RoHS certification.

AMA-RD06 with the 90° die-cast bracket and the rear photocell position
Up to 180 lm/W: the same road on fewer watts
Up to 180 lm/W. A 100 W AMA-RD06 puts out roughly 18,000 lm, which is the output a 150 W luminaire reaches at 120 lm/W.
Efficacy decides most of the running cost. At 180 lm/W, nearly all of the input watt goes out as light; at 120 lm/W a third of it goes into heat instead. On a road that needs about 18,000 lm, that is the difference between hanging a 100 W fitting and a 150 W one on the same pole.
The saving lands in three places. The feeder carries a smaller load, the energy line on the bill comes down by the same ratio, and there is less heat to move out of the housing. The last one is the part that ages a driver, so it buys service life as well as kilowatt hours.
Efficacy is quoted at 170–180 lm/W across the four builds. The range holds at every wattage because the optical stack and the thermal path stay the same from 50 W to 200 W.
What the bracket changes on site
A street light is more often let down by its mounting than by its LED. Wrong tilt, an adaptor kit that arrived late, or an angle that puts light into bedroom windows three streets over.
The 90° rotating die-cast aluminium holder covers horizontal mounting on a straight pole, vertical mounting at the top of a pole, and wall mounting off a building face. One bracket replaces the separate adaptor kits that distributors usually carry, which shortens the SKU list and the odds of shipping the wrong one to site.
The inclinometer is read directly while the crew adjusts the angle. On wall brackets this is where the job is won or lost: a few degrees decide whether the light lands on the footpath or washes up the facade. The holder takes a Ø60 mm spigot, the size most existing poles and outreach arms already use.
Eigenschaften
Tool-free power box, with a knife switch
The rear power compartment opens with a buckle. No screwdriver, no screws dropped in the mud at 2 a.m. Inside, the driver, terminals and surge module sit in a cool zone, separated from the LED board and heat sink in the hot zone.
A knife switch cuts the driver circuit as soon as the cover opens, so the light goes out before hands enter the box. For a maintenance team working at height, that removes a step that is easy to skip.

Power box open: driver, terminals and surge module in the cool zone
Heat path checked in simulation
The housing is ADC12 die-cast aluminium, chosen for thermal conductivity rather than looks. The LED board is a highly thermally conductive aluminium PCB clamped to the body, so heat leaves the chips and enters the casting instead of sitting in the board.
The engineering team ran finite element analysis on the whole housing: conduction through the casting, air convection along the fins, and radiation from the surface. At 150W the temperature curve flattens within the first hour of switch-on and stays there. That is the behaviour that matters on a summer afternoon with the sun on the same face.

Thermal simulation: conduction through the ADC12 body and convection along the fins
Optics: Type II and Type III
Two distributions ship as standard. Type II keeps a narrower pattern for footpaths, cycle tracks and residential streets with close pole spacing. Type III spreads wider for carriageways, parking rows and squares.
The optical stack is a nano-PC reflector, a UV-stabilised PC lens and tempered glass. Each layer does a different job: the reflector shapes the beam, the lens protects the LEDs and evens out the output, the glass takes the impact and the cleaning.
Both distributions are cut-off designs, so light stays on the road surface instead of spilling onto walls and windows. Send road width, mounting height and the scene, and the team will run a DIALux simulation and return a layout with pole spacing.
Surge, impact and weather
Every model carries a surge protection module rated 10 kV or 20 kV, depending on the build ordered. Rural feeders and coastal sites with heavy switching on the line are where this earns back its cost.
Impact rating is IK09 and the front cover is tempered glass rather than acrylic. A breather valve equalises pressure inside the housing as temperature swings, which stops moist air being pulled in through the glands. Cable entry uses a waterproof gland, and the light source is sealed with UV-resistant silicone gel.
The working range is −40 °C to +45 °C, wide enough for northern winters and unshaded desert installations.
Finish and wind load
The casting is finished in Akzo powder coating. It resists chalking, peeling at the edges is rare, and salt air and roadside grit do not take it off in the first season.
The profile is streamlined and the photocell sits at the rear rather than on top of the housing. Lower wind load means less stress on the bracket, and on exposed sites it can pull the pole specification down a size.
Installation and angle adjustment
Horizontal, vertical and wall-mounted arrangements all run off the same bracket, with angle adjustment across 90°. The four installation photographs below show the typical setups: outreach arm, top of pole, wall bracket, and the tilt range.

Mounting options: horizontal, vertical, wall bracket and angle adjustment
Specifications
| Parameter | 50 W | 100 W | 150 W | 200 W |
| Input voltage | 90–305 V AC | 90–305 V AC | 90–305 V AC | 90–305 V AC |
| Power factor | >0.95 | >0.95 | >0.95 | >0.95 |
| Surge protection | 10 kV / 20 kV | 10 kV / 20 kV | 10 kV / 20 kV | 10 kV / 20 kV |
| Efficacy | 170–180 lm/W | 170–180 lm/W | 170–180 lm/W | 170–180 lm/W |
| Colour temperature | 3000–6500 K | 3000–6500 K | 3000–6500 K | 3000–6500 K |
| LED type and count | 3030, 96 pcs | 3030, 144 pcs | 3030, 240 pcs | 3030, 320 pcs |
| CRI | >70 | >70 | >70 | >70 |
| Beam angle | Type II / Type III | Type II / Type III | Type II / Type III | Type II / Type III |
| Impact protection | IK09 | IK09 | IK09 | IK09 |
| Ambient temperature | −40 °C to +45 °C | −40 °C to +45 °C | −40 °C to +45 °C | −40 °C to +45 °C |
| Luminaire size (L×W×H) | 410×180×96 mm | 520×180×96 mm | 620×215×96 mm | 620×265×96 mm |
| Zertifizierung | CE, RoHS | CE, RoHS | CE, RoHS | CE, RoHS |
The LED count changes with the wattage: 96 chips at 50W, 144 at 100W, 240 at 150W and 320 at 200W, all in 3030 packages.
Dimensions, packing and container loading
| Modell | Strom | Luminaire (mm) | Carton (cm) | Pcs/ctn | 20′ GP | 40′ GP | 40′ HQ |
| AMA-RD06-50W | 50 W | 410×180×96 | 51×21×13 | 1 | 2,011 | 4,166 | 4,884 |
| AMA-RD06-100W | 100 W | 520×180×96 | 61×21×13 | 1 | 1,681 | 3,483 | 4,083 |
| AMA-RD06-150W | 150 W | 620×215×96 | 71×25×13 | 1 | 1,213 | 2,514 | 2,947 |
| AMA-RD06-200W | 200 W | 620×265×96 | 71×30×13 | 1 | 1,011 | 2,095 | 2,456 |
Each luminaire ships one per carton, packed in EVA foam at both ends of the housing. A 40HQ container holds 4,884 pieces of the 50W build and 2,456 pieces of the 200W build.
Choosing the wattage
| Modell | Einbauhöhe | Typical application |
| 50 W | 2–4 m | Footpaths, courtyards, parking bays, park lighting |
| 100 W | 4–6 m | Residential streets, estate roads, community roads |
| 150 W | 7–8 m | Collector roads, industrial access roads |
| 200 W | 9–10 m | Main roads and trunk roads |
These heights are the factory recommendation. Pole spacing is a separate calculation: it depends on the illuminance class in the standard your project is designed to, not on the wattage alone. A 200W luminaire spaced badly will read darker on the road than a 100W unit spaced well.
Where the AMA-RD06 is used
Municipal and residential roads are the main line of work: carriageways, estate roads and the access roads around industrial sites. The smaller jobs usually ship with the same order: courtyard lighting, park paths, village squares, car parks and community streets on rural road programmes.
Wall mounting makes it useful where there is no pole to raise, and the photocell option lets a site run dusk-to-dawn switching without a control cabinet or a timer.
What you can specify
- Wattage: 50W, 100W, 150W or 200W
- Colour temperature: 3000 K to 6500 K
- Distribution: Type II or Type III
- Surge module: 10 kV or 20 kV
- Photocell: light sensor for dusk-to-dawn switching
- Housing colour: standard grey; [other RAL colours on request]
- Branding: Amasly label and laser marking, or your own brand on OEM orders
- Documentation: DIALux layout, CE and RoHS declarations, [test reports on request]
- Commercial: [MOQ], [lead time], [price], [warranty]
Häufig gestellte Fragen
What is the difference between Type II and Type III optics?
Type II concentrates light along the road axis with a narrower spread, which suits footpaths and residential streets with close poles. Type III widens the pattern across the carriageway, so it covers more lanes from the same mounting height. Choose by road width and pole spacing, not by wattage.
Can the AMA-RD06 replace an existing high-pressure sodium fixture?
Usually yes, if the pole has a Ø60 mm spigot. The bracket covers horizontal and vertical mounting, so most existing arms can be reused. Check the safe working load on the pole before you add weight or move up a wattage.
Does it come with a photocell?
A light sensor can be fitted for dusk-to-dawn operation. The housing has a dedicated rear position for it, so the sensor does not sit in the beam or cast a shadow on the lens. [Confirm the option code with the factory before you order.]
What input voltage does the driver accept?
90–305 V AC, with a power factor above 0.95. That covers 120V and 230V markets on one SKU, and it rides out the voltage sag that shows up on rural feeders.
How do I know which wattage to order?
Start with mounting height and road class: 50W for 2–4 m, 100W for 4–6 m, 150W for 7–8 m, 200W for 9–10 m. Confirm with a DIALux run, because the required lux comes from the road class in your local standard.
What certifications are included?
CE and RoHS as standard. [Add the approvals your market requires, such as local grid-connection approval or energy label registration, before you publish a list.]
Ask for a layout and a price
Send four things and you get a DIALux layout plus a quotation: road width and length, mounting height, the road class or target illuminance, and the ambient temperature range on site. A pole schedule works too, if one already exists.Email: [sales@amasly.com] WhatsApp: [+86 13732643699]
Amasly Light FAQ
Q1. kann ich eine Probe Bestellung für LED-Licht haben?
A: Ja, wir begrüßen Musterbestellungen, um die Qualität zu testen und zu überprüfen. Gemischte Proben sind akzeptabel.
F2: Wie sieht es mit der Vorlaufzeit aus?
A: Muster brauchen 3-5 Tage, die Massenproduktion braucht 1-2 Wochen.
Q3.do Sie haben keine MOQ Grenze für led Licht bestellen?
A: Niedrige MOQ 1pc für Probe Überprüfung ist verfügbar.
Q4. Wie versenden Sie die Waren und wie lange dauert es, bis sie ankommen?
A: Wir versenden normalerweise per DHL, UPS, FedEx oder TNT. Es dauert in der Regel 3-5 Tage, um anzukommen. Luftlinie und Meer Versand auch optional.
Q5. Wie man einen Auftrag für geführtes Licht fortfährt?
A:
Teilen Sie uns zunächst Ihre Anforderungen oder Ihren Antrag mit.
Zweitens erstellen wir ein Angebot entsprechend Ihren Anforderungen oder unseren Vorschlägen.
Drittens bestätigt der Kunde die Muster und hinterlegt eine Anzahlung für die offizielle Bestellung.
Viertens: Wir organisieren die Produktion.
Q6: Ist es in Ordnung, meine LOGO über das Produkt led light ?
A: Ja. Bitte informieren Sie uns formell vor der Produktion und bestätigen Sie den Entwurf zunächst auf der Grundlage unseres Musters.
Q7: Bieten Sie eine Garantie für Ihre Produkte an?
A: Ja, wir bieten 2-5 Jahre Garantie auf unsere Produkte.
F8: Wie geht man mit Fehlern um?
A:
Erstens sind unsere Produkte produzieren dinstrict Qualitätskontrolle System und die fehlerhafte Rate wird weniger als 0,2% sein
Zweitens werden wir während der Garantiezeit Teile zur Verfügung stellen, um das defekte Teil zu ersetzen. Bei Großbestellungen bieten wir anfällige Teile im Voraus an, oder wir können Lösungen einschließlich Rückrufe auf der Grundlage der tatsächlichen Situation besprechen.
F9: Können wir explosionsgeschützte Niedervolt-Lampen mit AC/DC-Spannungen von 12V, 24V, 36V oder 48V herstellen?
Amasly kann sowohl als Niederspannungs- als auch als Hochspannungsexplosionsschutzleuchte verwendet werden - AC/DC 12V, 24V, 36V, 48V, AC 85-265V, AC 380V.
Q10: Können Explosion Poof Lights Notbatterien hinzugefügt werden?
Die explosionsgeschützte Lampe Amasly kann mit Lithium-Notstrombatterien ausgestattet werden. Die Notlaufzeit beträgt 90 Minuten, 120 Minuten oder 180 Minuten.
Q11: Kann die Amasly explosionsgeschützte Lampe als OEM-Produkt angepasst werden?
Die explosionsgeschützten Lampen von Amasly können je nach Kundenwunsch sowohl für die Lampen als auch für die Verpackungskartons angepasst werden.