{"id":2038,"date":"2025-02-27T20:00:16","date_gmt":"2025-02-27T12:00:16","guid":{"rendered":"https:\/\/led.amasly.com\/?p=2038"},"modified":"2025-03-06T22:22:19","modified_gmt":"2025-03-06T14:22:19","slug":"mobile-and-portable-explosion-proof-equipment-explosionproof-flashlight-explosionproof-cell-phone-introduction","status":"publish","type":"post","link":"https:\/\/led.amasly.com\/tr\/light\/mobile-and-portable-explosion-proof-equipment-explosionproof-flashlight-explosionproof-cell-phone-introduction\/","title":{"rendered":"Mobil ve ta\u015f\u0131nabilir patlamaya dayan\u0131kl\u0131 ekipman patlamaya dayan\u0131kl\u0131 el feneri ve patlamaya dayan\u0131kl\u0131 cep telefonu tan\u0131t\u0131m\u0131"},"content":{"rendered":"<h1 class=\"wp-block-heading has-text-align-center\"><strong>M<\/strong><strong>mobi\u0307l ve portati\u0307f patlamaya dayanikli eki\u0307pman - patlama<\/strong><strong>&nbsp;<\/strong><strong>patlamaya dayan\u0131kl\u0131 el feneri<\/strong><strong>&nbsp;<\/strong><strong>kan\u0131t cep telefonu tan\u0131t\u0131m\u0131<\/strong><strong><\/strong><\/h1>\n\n\n\n<p>Patlay\u0131c\u0131 tehlikeli ortamlar i\u00e7eren \u00fcretim sahas\u0131nda, patlamaya dayan\u0131kl\u0131 cep telefonlar\u0131, patlamaya dayan\u0131kl\u0131 telsizler, patlamaya dayan\u0131kl\u0131 el fenerleri ve di\u011fer mobil patlamaya dayan\u0131kl\u0131 elektrikli ekipmanlar yayg\u0131n olarak kullan\u0131lmaktad\u0131r.<\/p>\n\n\n\n<div class=\"wp-block-uagb-image uagb-block-29a07795 wp-block-uagb-image--layout-default wp-block-uagb-image--effect-static wp-block-uagb-image--align-none\"><figure class=\"wp-block-uagb-image__figure\"><a class=\"\" href=\"https:\/\/led.amasly.com\/tr\/products\/\" target=\"\" rel=\"noopener\"><img decoding=\"async\" srcset=\"https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/12\/explosion-proof-flashlights-explosion-proof-mobile-work-lights.jpg ,https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/12\/explosion-proof-flashlights-explosion-proof-mobile-work-lights.jpg 780w, https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/12\/explosion-proof-flashlights-explosion-proof-mobile-work-lights.jpg 360w\" sizes=\"auto, (max-width: 480px) 150px\" src=\"https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/12\/explosion-proof-flashlights-explosion-proof-mobile-work-lights.jpg\" alt=\"\" class=\"uag-image-1584\" width=\"863\" height=\"273\" title=\"patlamaya dayan\u0131kl\u0131 el fenerleri patlamaya dayan\u0131kl\u0131 mobil \u00e7al\u0131\u015fma lambalar\u0131\" loading=\"lazy\" role=\"img\"><\/a><\/figure><\/div>\n\n\n\n<p>Patlama tehlikesi olan gaz ortam\u0131 mobil ekipman\u0131 ve ta\u015f\u0131nabilir ekipman se\u00e7imi genel gereklilikleri kal\u0131c\u0131 olarak kurulan ekipmandan farkl\u0131d\u0131r, mobil ekipman veya ta\u015f\u0131nabilir ekipman tehlikeli yerlerde yaln\u0131zca ge\u00e7ici olarak kullan\u0131l\u0131r. Bu t\u00fcr ekipmanlar \u015funlar\u0131 i\u00e7erebilir: acil durum jenerat\u00f6rleri, kaynak makineleri, end\u00fcstriyel kald\u0131rma ara\u00e7lar\u0131 (forkliftler), hava kompres\u00f6rleri, elektrikli fanlar veya \u00fcfleyiciler, ta\u015f\u0131nabilir elektrikli aletler, belirli alg\u0131lama ekipmanlar\u0131.<\/p>\n\n\n\n<p>Tehlikeli bir yere girebilecek veya getirilebilecek ekipman uygun bir ekipman koruma seviyesine sahip olmal\u0131d\u0131r. Tehlikeli bir yerde kullan\u0131lan mobil veya ta\u015f\u0131nabilir ekipman rutin olarak gerekli EPL seviyesini kar\u015f\u0131lam\u0131yorsa, belgelendirilmi\u015f bir tehlike y\u00f6netimi prosed\u00fcr\u00fc uygulanmal\u0131d\u0131r. Prosed\u00fcr uygun e\u011fitimi, prosed\u00fcrleri ve kontrolleri i\u00e7ermelidir.<\/p>\n\n\n\n<p>Kullan\u0131m gerekliliklerine ve kullan\u0131m esnekli\u011fine ba\u011fl\u0131 olarak, farkl\u0131 konumlar mobil ekipman, ta\u015f\u0131nabilir ekipman kullan\u0131m\u0131n\u0131 gerektirebilir. Daha y\u00fcksek EPL seviyeleri gerektiren alanlarda, aksi belirtilmedik\u00e7e, daha d\u00fc\u015f\u00fck EPL seviyelerine sahip ekipmanlar kullan\u0131lmamal\u0131d\u0131r. Ancak uygulamada, \u00f6zellikle ta\u015f\u0131nabilir ekipman i\u00e7in b\u00f6yle bir k\u0131s\u0131tlaman\u0131n uygulanmas\u0131 zor olabilir. Bu nedenle, t\u00fcm ekipman\u0131n en y\u00fcksek EPL seviyesini gerektiren alan\u0131n gerekliliklerine uygun olmas\u0131 tavsiye edilir. Benzer \u015fekilde, ekipman kategorisinin ve s\u0131cakl\u0131k grubunun ekipman\u0131n kullan\u0131ld\u0131\u011f\u0131 yerlerde kar\u015f\u0131la\u015f\u0131lmas\u0131 muhtemel t\u00fcm gazlar, buharlar ve tozlar i\u00e7in uygun olmas\u0131 arzu edilir. Uygun \u00f6nlemler al\u0131nmad\u0131\u011f\u0131 s\u00fcrece yedek bataryalar tehlikeli yerlere g\u00f6t\u00fcr\u00fclmemelidir.<\/p>\n\n\n\n<p>Kablolarda metalik esnek z\u0131rh veya ekranlama kullan\u0131lan mobil veya ta\u015f\u0131nabilir elektrikli ekipmanlar i\u00e7in, z\u0131rh veya ekranlama tek koruyucu iletken olarak kullan\u0131lmamal\u0131d\u0131r. Kablo, \u00f6rne\u011fin toprak izleme kullan\u0131ld\u0131\u011f\u0131nda devre koruma d\u00fczenine uygun olmal\u0131 ve gereken say\u0131da iletken i\u00e7ermelidir. Ekipman\u0131n topraklanmas\u0131 gerekiyorsa, kablo topraklama iletkenine (PE) ek olarak topraklanm\u0131\u015f esnek bir metal ekran i\u00e7erebilir.<\/p>\n\n\n\n<p>Mobil (elde tutulan, ta\u015f\u0131nabilir ve s\u00f6k\u00fclebilir) elektrikli ekipman hasara veya yanl\u0131\u015f kullan\u0131ma kar\u015f\u0131 \u00f6zellikle hassast\u0131r, bu nedenle birbirini izleyen denetimler aras\u0131ndaki aral\u0131klar pratik olarak k\u0131salt\u0131labilir. Mobil elektrikli ekipman en az 12 ayda bir denetlenmeli ve s\u0131k s\u0131k a\u00e7\u0131lan muhafazalar (\u00f6rne\u011fin ak\u00fc kapaklar\u0131) ayr\u0131nt\u0131l\u0131 olarak incelenmelidir. Buna ek olarak, bu t\u00fcr ekipmanlar, ekipmanda belirgin bir hasar olmad\u0131\u011f\u0131ndan emin olmak i\u00e7in kullan\u0131lmadan \u00f6nce g\u00f6rsel olarak incelenmelidir.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Patlamaya dayan\u0131kl\u0131 bilgi on soru<\/strong><strong><\/strong><\/h2>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>1 Patlamaya dayan\u0131kl\u0131 olmayan bir cep telefonu kullanarak yan\u0131c\u0131 ve patlay\u0131c\u0131 saha incelemesi, telefonun foto\u011fraf \u00e7ekmek i\u00e7in u\u00e7u\u015f modu durumuna ge\u00e7mesi, gereksinimleri kar\u015f\u0131l\u0131yor mu?<\/strong><strong><\/strong><\/h3>\n\n\n\n<p>Her \u015feyden \u00f6nce, yan\u0131c\u0131 ve patlay\u0131c\u0131 alan\u0131n patlamaya dayan\u0131kl\u0131 bir alan olup olmad\u0131\u011f\u0131n\u0131 anlaman\u0131z gerekir. Patlamaya dayan\u0131kl\u0131 olmayan bir alandaysa, teorik olarak foto\u011fraf \u00e7ekmek i\u00e7in u\u00e7u\u015f modunu kullanabilirsiniz. Patlamaya dayan\u0131kl\u0131 bir alandaysa, patlamaya dayan\u0131kl\u0131 olmayan elektrikli aletleri kullanamazs\u0131n\u0131z. Yan\u0131c\u0131 ve patlay\u0131c\u0131 yerler, k\u0131v\u0131lc\u0131m, statik elektrik vb. patlamalara veya yang\u0131nlara neden olabilece\u011finden \u00e7ok y\u00fcksek g\u00fcvenlik riski olu\u015fturur. Patlamaya dayan\u0131kl\u0131 olmayan cep telefonlar\u0131 patlamaya kar\u015f\u0131 \u00f6zel \u00f6nlemlerle tasarlanmam\u0131\u015f ve \u00fcretilmemi\u015ftir ve dahili devreleri ve pilleri \u00e7al\u0131\u015fma s\u0131ras\u0131nda k\u00fc\u00e7\u00fck elektrik k\u0131v\u0131lc\u0131mlar\u0131 olu\u015fturabilir veya statik elektrik yayabilir, b\u00f6ylece potansiyel bir ate\u015fleme kayna\u011f\u0131 haline gelebilir. U\u00e7u\u015f modu yaln\u0131zca cep telefonunun ileti\u015fim i\u015flevini kapat\u0131r, ancak cep telefonunun devre \u00f6zelliklerini ve potansiyel tehlikeli fakt\u00f6rlerini de\u011fi\u015ftirmez. Personelin can g\u00fcvenli\u011fini ve tesisin g\u00fcvenli\u011fini ve istikrar\u0131n\u0131 sa\u011flamak i\u00e7in, foto\u011fraf \u00e7ekme gibi i\u015flemler i\u00e7in patlamaya dayan\u0131kl\u0131 olarak sertifikaland\u0131r\u0131lm\u0131\u015f \u00f6zel ekipman kullan\u0131lmal\u0131d\u0131r.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>2 gaz kazan\u0131 odas\u0131 (Kategori D, a\u00e7\u0131k alev) patlama tehlikesi olan alanlara nas\u0131l ayr\u0131l\u0131r? Patlamaya dayan\u0131kl\u0131 elektrikli ekipman tipi nas\u0131l se\u00e7ilir?<\/strong><strong><\/strong><\/h3>\n\n\n\n<p>A\u00e7\u0131k alevli ekipmanlar\u0131n kullan\u0131ld\u0131\u011f\u0131 \u00fcretim s\u00fcrecinde veya pi\u015firme s\u0131cak y\u00fczey s\u0131cakl\u0131\u011f\u0131n\u0131n yan\u0131c\u0131 gazlar\u0131n s\u0131cakl\u0131\u011f\u0131n\u0131 a\u015ft\u0131\u011f\u0131 alanlar\u0131n yak\u0131n\u0131nda bulunan ekipmanlar\u0131n tutu\u015fma s\u0131cakl\u0131\u011f\u0131. Kazan dairesi, s\u0131cak su oca\u011f\u0131 odas\u0131 gibi. Di\u011fer binalarda bulunan ya\u011f, gaz kazan dairesi kazan dairesi, hava besleme ve egzoz sisteminden ba\u011f\u0131ms\u0131z olarak kurulmal\u0131, havaland\u0131rma tertibat\u0131 patlamaya dayan\u0131kl\u0131 olmal\u0131d\u0131r. Bu nedenle, gaz kazan\u0131 odas\u0131 patlama tehlikesi olan alanlara b\u00f6l\u00fcnemez. Gaz kazan\u0131 odas\u0131 havaland\u0131rma cihaz\u0131 patlamaya dayan\u0131kl\u0131 ekipman kullan\u0131lmal\u0131d\u0131r.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>3 hidrojen peroksit tank\u0131 transfer pompas\u0131 motorunun patlamaya dayan\u0131kl\u0131 olmas\u0131 gerekir mi? Patlamaya dayan\u0131kl\u0131l\u0131k seviyesi nas\u0131l belirlenir?<\/strong><strong><\/strong><\/h3>\n\n\n\n<p>Basit hidrojen peroksit depolama tanklar\u0131, batardo aral\u0131\u011f\u0131 patlamaya dayan\u0131kl\u0131l\u0131k gerektirmez. Depolama tanklar\u0131, A S\u0131n\u0131f\u0131 tank aral\u0131\u011f\u0131na g\u00f6re d\u00fc\u015f\u00fcn\u00fclebilir, tanklar ve \u00fcretim ekipman\u0131 yang\u0131n ayr\u0131m\u0131n\u0131 korumak i\u00e7in, tanklar patlamaya dayan\u0131kl\u0131 elektrik olmayabilir; ba\u015fka gazlar veya toz gibi, basit hidrojen peroksit ortam\u0131 se\u00e7mek i\u00e7in iyi bir a\u015f\u0131nd\u0131r\u0131c\u0131 koruma seviyesi olabilir, patlamaya dayan\u0131kl\u0131 ayarlar \u00e7ok az \u00f6neme sahiptir.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>4 sodyum ditiyonit yan\u0131c\u0131 bir toz mudur?<\/strong><strong><\/strong><\/h3>\n\n\n\n<p>Sodyum ditiyonit, \u201cend\u00fcstriyel ve ticari end\u00fcstri anahtar yan\u0131c\u0131 toz dizininde (2015 bask\u0131s\u0131)\u201d yer almamaktad\u0131r, dizinde yer almayan toz ve patlamaya dayan\u0131kl\u0131 standartlar i\u00e7in GB \/ T 3836.12-2019 \u201cpatlay\u0131c\u0131 ortam B\u00f6l\u00fcm 12: yan\u0131c\u0131 toz maddelerinin \u00f6zellikleri i\u00e7in test y\u00f6ntemleri\u201d standard\u0131na uygun olarak tan\u0131mlama.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>5 C s\u0131n\u0131f\u0131 cihazlar\u0131n patlama tehlikesi olan alanlara b\u00f6l\u00fcnmesi gerekir mi? Elektrik tesisatlar\u0131n\u0131n tasar\u0131m\u0131nda patlay\u0131c\u0131 atmosfer ortam\u0131nda hangi durumlar ger\u00e7ekle\u015ftirilmelidir?<\/strong><strong><\/strong><\/h3>\n\n\n\n<p>C s\u0131n\u0131f\u0131 \u00e7al\u0131\u015fma s\u0131cakl\u0131\u011f\u0131 parlama noktas\u0131n\u0131 a\u015ft\u0131\u011f\u0131nda da patlama tehlikesi olan alanlara b\u00f6l\u00fcnmelidir, elektriksel olarak patlamaya dayan\u0131kl\u0131 olmas\u0131 gerekip gerekmedi\u011fine bak\u0131lmaks\u0131z\u0131n \u201cpatlama tehlikesi olan ortam enerji santrali tasar\u0131m \u00f6zellikleri\u201d 3.1.1 \u00fcretim, i\u015fleme, ta\u015f\u0131ma, transit veya depolama s\u00fcrecinde veya ortamda a\u015fa\u011f\u0131daki patlay\u0131c\u0131 gaz kar\u0131\u015f\u0131mlar\u0131ndan birinin bulunma olas\u0131l\u0131\u011f\u0131, patlay\u0131c\u0131 gaz ortamlar\u0131 i\u00e7in elektrik tesisatlar\u0131n\u0131n tasar\u0131m\u0131 olmal\u0131d\u0131r:<\/p>\n\n\n\n<p>(1) atmosferik ko\u015fullar alt\u0131nda, patlay\u0131c\u0131 gaz kar\u0131\u015f\u0131mlar\u0131 olu\u015fturmak i\u00e7in hava ile kar\u0131\u015fan yan\u0131c\u0131 gazlar;<\/p>\n\n\n\n<p>(2) patlay\u0131c\u0131 gaz kar\u0131\u015f\u0131mlar\u0131 olu\u015fturmak i\u00e7in hava ile kar\u0131\u015fan yan\u0131c\u0131 s\u0131v\u0131 buhar veya bu\u011funun ortam s\u0131cakl\u0131\u011f\u0131na e\u015fit veya daha d\u00fc\u015f\u00fck parlama noktas\u0131;<\/p>\n\n\n\n<p>(3) malzeme \u00e7al\u0131\u015fma s\u0131cakl\u0131\u011f\u0131 yan\u0131c\u0131 s\u0131v\u0131lar\u0131n parlama noktas\u0131ndan daha y\u00fcksek oldu\u011funda, yan\u0131c\u0131 s\u0131v\u0131lar s\u0131z\u0131nt\u0131 yapabildi\u011finde, yan\u0131c\u0131 s\u0131v\u0131lar, buharlar veya sisler hava ile kar\u0131\u015farak patlay\u0131c\u0131 gaz kar\u0131\u015f\u0131mlar\u0131 olu\u015fturabilir.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>6 Grafit tozu yan\u0131c\u0131 toz olarak kabul edilebilir mi?<\/strong><strong><\/strong><\/h3>\n\n\n\n<p>Grafit tozu s\u0131n\u0131f IIIC yan\u0131c\u0131 iletken tozdur.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>7 Gaz alarmlar\u0131n\u0131n yerinde incelenmesi genellikle hangi sorunlar\u0131 ortaya \u00e7\u0131karacakt\u0131r?<\/strong><strong><\/strong><\/h3>\n\n\n\n<p>Genel olarak a\u015fa\u011f\u0131daki t\u00fcrler olacakt\u0131r:<\/p>\n\n\n\n<p>(1) Eksik: Kurulmas\u0131 gereken alan ayarlanmam\u0131\u015ft\u0131r;<\/p>\n\n\n\n<p>(2) Konum hatas\u0131: y\u00fckseklik veya koordinatlar aral\u0131\u011f\u0131 etkili bir \u015fekilde kapsayamaz;<\/p>\n\n\n\n<p>(3) Se\u00e7im hatas\u0131: patlamaya dayan\u0131kl\u0131 s\u0131n\u0131f e\u015fle\u015fmiyor;<\/p>\n\n\n\n<p>(4) Konfig\u00fcrasyon hatas\u0131: zehirli ve yan\u0131c\u0131 ayn\u0131 anda, her iki fonksiyonla da donat\u0131lmam\u0131\u015f;<\/p>\n\n\n\n<p>(5) Menzil hatas\u0131: menzil ve uygulanabilir gaz aras\u0131ndaki uyumsuzluk;<\/p>\n\n\n\n<p>(6) Aral\u0131k do\u011frulu\u011fu: aral\u0131\u011f\u0131n ve standard\u0131n gerektirdi\u011fi do\u011fruluk yeterli de\u011fildir;<\/p>\n\n\n\n<p>(7) Miktar sorunu: miktar \u00e7ok az ve kapsam yetersiz;<\/p>\n\n\n\n<p>(8) Tespit sorunlar\u0131: test ve kalibrasyonun yap\u0131lmamas\u0131 veya d\u00f6ng\u00fcye g\u00f6re kalibre edilmemesi;<\/p>\n\n\n\n<p>(9) Alarm sorunlar\u0131: alarmlar kaydedilir ancak imha edilmez;<\/p>\n\n\n\n<p>(10) Kurulum sorunlar\u0131: alarm \u015firketleri profesyonel tasar\u0131m olmadan kendi ba\u015flar\u0131na kurulum yaparlar;<\/p>\n\n\n\n<p>(11) Alarm fonksiyonlar\u0131: sesli ve \u0131\u015f\u0131kl\u0131 alarmlar, alan alarmlar\u0131 uygun \u015fekilde kurulmam\u0131\u015f ve kullan\u0131lmam\u0131\u015ft\u0131r;<\/p>\n\n\n\n<p>(12) bak\u0131m ve onar\u0131m y\u00f6netimi konular\u0131: normal \u00e7al\u0131\u015fma olup olmad\u0131\u011f\u0131, d\u00fczenli muayene, bak\u0131m, kalibrasyon olup olmad\u0131\u011f\u0131.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>8. Laboratuvarda A ve B s\u0131n\u0131f\u0131 tesis kurulamayaca\u011f\u0131na dair net bir \u015fartname yok mu?<\/strong><strong><\/strong><\/h3>\n\n\n\n<p>Laboratuvar, ofis ve di\u011fer ekipmanlar\u0131n yang\u0131n tehlikesine bakan d\u0131\u015f duvar\u0131nda yanmaz malzemeden masif duvara a\u00e7\u0131lan pencere ve kap\u0131 olmamal\u0131d\u0131r. Pencere ve kap\u0131 a\u00e7\u0131lmas\u0131 gerekti\u011finde yang\u0131n kap\u0131s\u0131 ve penceresi kullan\u0131lmal\u0131d\u0131r.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>9 borudan ge\u00e7en kablo veya patlamaya dayan\u0131kl\u0131 hortum kullan\u0131m\u0131 patlamaya dayan\u0131kl\u0131l\u0131kta rol oynayabilir mi?<\/strong><strong><\/strong><\/h3>\n\n\n\n<p>Mekanik koruma ve enerji bast\u0131rmada rol oynayabilir, ancak patlamaya dayan\u0131kl\u0131 bir rol oynayamaz, patlamaya dayan\u0131kl\u0131 rol ekipman g\u00f6vdesi elektrik aray\u00fcz \u00f6nlemleridir.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>10 gaz ortam\u0131 patlamaya dayan\u0131kl\u0131 elektrikli ekipman toz patlamas\u0131 tehlikeli alanlar i\u00e7in kullan\u0131labilir mi?<\/strong><strong><\/strong><\/h3>\n\n\n\n<p>Hay\u0131r.<\/p>\n\n\n\n<p>(1) patlamaya dayan\u0131kl\u0131 ekipman\u0131n gaz patlamas\u0131na dayan\u0131kl\u0131 ve toz patlamas\u0131na dayan\u0131kl\u0131 \u00e7ift sertifikas\u0131 hem gaz ortam\u0131nda hem de toz ortam\u0131nda kullan\u0131labilir; ekipman\u0131n sadece gaz patlamas\u0131na dayan\u0131kl\u0131 sertifikas\u0131 toz ortam\u0131nda kullan\u0131lamaz, ekipman\u0131n sadece toz patlamas\u0131na dayan\u0131kl\u0131 sertifikas\u0131 gaz ortam\u0131nda kullan\u0131lamaz.<\/p>\n\n\n\n<p>(2) \u00e7evre grubuna ve patlamaya dayan\u0131kl\u0131 alan kullan\u0131m\u0131na dikkat edilmesi gerekir. Patlay\u0131c\u0131 gazlar\u0131n ve toz alanlar\u0131n\u0131n e\u015fzamanl\u0131 varl\u0131\u011f\u0131 i\u00e7in, patlamaya dayan\u0131kl\u0131 elektrikli ekipman se\u00e7imi hem patlay\u0131c\u0131 gaz patlamaya dayan\u0131kl\u0131l\u0131k gereksinimlerini kar\u015f\u0131lamal\u0131, hem de patlay\u0131c\u0131 toz patlamaya dayan\u0131kl\u0131l\u0131k gereksinimlerini kar\u015f\u0131lamal\u0131 ve ayn\u0131 zamanda gaz ve toz patlamaya dayan\u0131kl\u0131l\u0131k i\u015faretlemesi de dahil olmak \u00fczere patlamaya dayan\u0131kl\u0131l\u0131k i\u015faretlemesini kar\u015f\u0131lamal\u0131d\u0131r.<\/p>","protected":false},"excerpt":{"rendered":"<p>Mobile and portable explosion-proof equipment &#8211; explosion&nbsp;proof flashlight, explosion&nbsp;proof cell phone introduction In the production site containing explosive hazardous environments, explosion-proof cell phones, explosion-proof walkie-talkies, explosion-proof flashlights and other mobile explosion-proof electrical equipment is widely used. Explosion-hazardous gas environment mobile equipment and portable equipment selection general requirements are different from permanently installed equipment, mobile equipment [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_uag_custom_page_level_css":"","site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[7],"tags":[10,11],"class_list":["post-2038","post","type-post","status-publish","format-standard","hentry","category-light","tag-explosion-proof-flashlight","tag-explosionproof-cell-phone"],"uagb_featured_image_src":{"full":false,"thumbnail":false,"medium":false,"medium_large":false,"large":false,"1536x1536":false,"2048x2048":false,"trp-custom-language-flag":false},"uagb_author_info":{"display_name":"Joe","author_link":"https:\/\/led.amasly.com\/tr\/author\/jacklin\/"},"uagb_comment_info":0,"uagb_excerpt":"Mobile and portable explosion-proof equipment &#8211; explosion&nbsp;proof flashlight, explosion&nbsp;proof cell phone introduction In the production site containing explosive hazardous environments, explosion-proof cell phones, explosion-proof walkie-talkies, explosion-proof flashlights and other mobile explosion-proof electrical equipment is widely used. Explosion-hazardous gas environment mobile equipment and portable equipment selection general requirements are different from permanently installed equipment, mobile equipment&hellip;","_links":{"self":[{"href":"https:\/\/led.amasly.com\/tr\/wp-json\/wp\/v2\/posts\/2038","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/led.amasly.com\/tr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/led.amasly.com\/tr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/led.amasly.com\/tr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/led.amasly.com\/tr\/wp-json\/wp\/v2\/comments?post=2038"}],"version-history":[{"count":4,"href":"https:\/\/led.amasly.com\/tr\/wp-json\/wp\/v2\/posts\/2038\/revisions"}],"predecessor-version":[{"id":2278,"href":"https:\/\/led.amasly.com\/tr\/wp-json\/wp\/v2\/posts\/2038\/revisions\/2278"}],"wp:attachment":[{"href":"https:\/\/led.amasly.com\/tr\/wp-json\/wp\/v2\/media?parent=2038"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/led.amasly.com\/tr\/wp-json\/wp\/v2\/categories?post=2038"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/led.amasly.com\/tr\/wp-json\/wp\/v2\/tags?post=2038"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}