{"id":2228,"date":"2025-03-04T20:45:40","date_gmt":"2025-03-04T12:45:40","guid":{"rendered":"https:\/\/led.amasly.com\/?p=2228"},"modified":"2025-03-06T22:38:58","modified_gmt":"2025-03-06T14:38:58","slug":"exterior-facilities-and-power-distribution-considerations-for-explosion-proof-analyzer-huts","status":"publish","type":"post","link":"https:\/\/led.amasly.com\/sk\/explosion-proof-equipment\/exterior-facilities-and-power-distribution-considerations-for-explosion-proof-analyzer-huts\/","title":{"rendered":"Vonkaj\u0161ie zariadenia a \u00favahy o rozvode energie pre nev\u00fdbu\u0161n\u00e9 analytick\u00e9 chatky"},"content":{"rendered":"<h1 class=\"wp-block-heading\"><strong>Vonkaj\u0161ie zariadenia a \u00favahy o rozvode energie pre nev\u00fdbu\u0161n\u00e9 analytick\u00e9 chatky<\/strong><strong><\/strong><\/h1>\n\n\n\n<p>V\u00e4\u010d\u0161ina kovovej kon\u0161trukcie nev\u00fdbu\u0161nej analytickej kab\u00edny je ne\u0161tandardn\u00fd v\u00fdrobok, ve\u013ekos\u0165 jej ve\u013ekosti mo\u017eno ur\u010di\u0165 pod\u013ea po\u010dtu analyz\u00e1torov, typov, zlo\u017eitosti syst\u00e9mu a prev\u00e1dzky a \u00fadr\u017eby priestoru a ponecha\u0165 primeran\u00e9 rezervy.<\/p>\n\n\n\n<div class=\"wp-block-uagb-image uagb-block-4209960d wp-block-uagb-image--layout-default wp-block-uagb-image--effect-static wp-block-uagb-image--align-none\"><figure class=\"wp-block-uagb-image__figure\"><img decoding=\"async\" srcset=\"https:\/\/led.amasly.com\/wp-content\/uploads\/2025\/03\/\u56fe\u724715-1.png 642w, https:\/\/led.amasly.com\/wp-content\/uploads\/2025\/03\/\u56fe\u724715-1-300x234.png 300w\" sizes=\"auto, (max-width: 480px) 150px\" src=\"https:\/\/led.amasly.com\/wp-content\/uploads\/2025\/03\/\u56fe\u724715-1.png\" alt=\"\" class=\"uag-image-2229\" width=\"642\" height=\"500\" title=\"\u56fe\u72471(5)\" loading=\"lazy\" role=\"img\"><\/figure><\/div>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>I. Vonkaj\u0161ie zariadenia kab\u00edny analyz\u00e1tora odoln\u00e9 proti v\u00fdbuchu<\/strong><strong><\/strong><\/h2>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>Nastavenia plynovej f\u013ea\u0161e<\/strong><strong><\/strong><\/h3>\n\n\n\n<p>Mimo chaty je mo\u017en\u00e9 zriadi\u0165 ochrann\u00fa re\u0165azov\u00fa pevn\u00fa konzolu na f\u013ea\u0161e, ktor\u00e1 sa pou\u017e\u00edva na umiestnenie nosn\u00fdch plynov\u00fdch flia\u0161 a \u0161tandardn\u00fdch plynov\u00fdch flia\u0161, v pr\u00edpade potreby je mo\u017en\u00e9 prida\u0165 z\u00e1bradlie na f\u013ea\u0161e, aby sa zabr\u00e1nilo pr\u00edstupu nespriaznen\u00fdch os\u00f4b. Vo vysokohorskej oblasti alebo v zl\u00fdch environment\u00e1lnych podmienkach mo\u017eno v chate oddeli\u0165 miestnos\u0165 pre f\u013ea\u0161e, ktor\u00e1 by mala by\u0165 vybaven\u00e1 samostatn\u00fdmi dverami, osvetlen\u00edm a vetrac\u00edm zariaden\u00edm. (T\u00e1to polo\u017eka je volite\u013en\u00e1)<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>Odolnos\u0165 vo\u010di da\u017e\u010fu a pr\u00edstre\u0161ok<\/strong><strong><\/strong><\/h3>\n\n\n\n<p>Dvere, spojovacie skrinky, stojany na f\u013ea\u0161e a skrinky na predbe\u017en\u00fa \u00fapravu vzoriek by mali by\u0165 nad pr\u00edstre\u0161kom proti da\u017e\u010fu alebo nad mal\u00fdm stre\u0161n\u00fdm odkvapom smerom von 600 ~ 800 mm, aby sa zabr\u00e1nilo zakrytiu da\u017e\u010fom.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>Syst\u00e9m distrib\u00facie energie<\/strong><strong><\/strong><\/h3>\n\n\n\n<p>Na hornej \u010dasti chatky by mal by\u0165 zdv\u00edhac\u00ed kr\u00fa\u017eok na celkov\u00e9 zdv\u00edhanie. Syst\u00e9m rozvodu energie nev\u00fdbu\u0161nej analytickej kab\u00edny je: rozvod osvetlenia, vetrania, vykurovania, klimatiz\u00e1cie a vn\u00fatorn\u00e9ho pr\u00edstrojov\u00e9ho vybavenia.<\/p>\n\n\n\n<p>Komun\u00e1lne zariadenia, ako napr\u00edklad osvetlenie, ventil\u00e1tory, klimatiz\u00e1cia a servisn\u00e9 z\u00e1suvky v nev\u00fdbu\u0161nej analytickej hale, s\u00fa nap\u00e1jan\u00e9 z priemyseln\u00e9ho zdroja. Syst\u00e9m analyz\u00e1tora, kontroln\u00fd alarm in\u0161tal\u00e1cie a blokovac\u00ed syst\u00e9m s\u00fa nap\u00e1jan\u00e9 zo zdroja UPS.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>II.<\/strong><strong>&nbsp;Anal\u00fdza rozvodu energie v kab\u00edne odolnej proti v\u00fdbuchu<\/strong><strong><\/strong><\/h2>\n\n\n\n<p>1, spolo\u010dn\u00e1 rozvodn\u00e1 skri\u0148a pr\u00edstrojovej distrib\u00facie by mala by\u0165 nez\u00e1visl\u00e1 od seba, nemala by by\u0165 kombinovan\u00e1 s rozvodnou skri\u0148ou alebo rozvodnou skri\u0148ou; r\u00f4zne \u00farovne nap\u00e4tia nap\u00e1jania (napr\u00edklad 380V AC, 220V AC, UPS, 24C DC) by mali by\u0165 tie\u017e nez\u00e1visl\u00e9 od seba, nemali by by\u0165 kombinovan\u00e9 s rozvodnou skri\u0148ou alebo rozvodnou skri\u0148ou.<\/p>\n\n\n\n<div class=\"wp-block-uagb-image uagb-block-9211f0b1 wp-block-uagb-image--layout-default wp-block-uagb-image--effect-static wp-block-uagb-image--align-none\"><figure class=\"wp-block-uagb-image__figure\"><a class=\"\" href=\"https:\/\/led.amasly.com\/sk\/products\/\" target=\"\" rel=\"noopener\"><img decoding=\"async\" srcset=\"https:\/\/led.amasly.com\/wp-content\/uploads\/2025\/03\/\u56fe\u724716-1.png ,https:\/\/led.amasly.com\/wp-content\/uploads\/2025\/03\/\u56fe\u724716-1.png 780w, https:\/\/led.amasly.com\/wp-content\/uploads\/2025\/03\/\u56fe\u724716-1.png 360w\" sizes=\"auto, (max-width: 480px) 150px\" src=\"https:\/\/led.amasly.com\/wp-content\/uploads\/2025\/03\/\u56fe\u724716-1.png\" alt=\"\" class=\"uag-image-2230\" width=\"750\" height=\"420\" title=\"\u56fe\u72471(6)\" loading=\"lazy\" role=\"img\"><\/a><\/figure><\/div>\n\n\n\n<p>2, rozvodn\u00e1 skri\u0148a nap\u00e1jania by mala by\u0165 umiestnen\u00e1 mimo chaty, nap\u00e1jacie vedenie by malo by\u0165 pripojen\u00e9 k anal\u00fdze chaty cez rozvodn\u00fa skri\u0148u.<\/p>\n\n\n\n<p>3, hlavn\u00fd vyp\u00edna\u010d by mal by\u0165 umiestnen\u00fd mimo chaty, aby bolo mo\u017en\u00e9 odpoji\u0165 nap\u00e1janie v pr\u00edpade nebezpe\u010dnej situ\u00e1cie vo vn\u00fatri chaty.<\/p>\n\n\n\n<p>4, rozvodn\u00e1 skri\u0148a sa nach\u00e1dza vo vn\u00fatri chaty, ka\u017ed\u00fd pr\u00edstroj a zariadenie by mali by\u0165 nap\u00e1jan\u00e9 a zapojen\u00e9 samostatne.<\/p>\n\n\n\n<p>5\u3001Ka\u017ed\u00fd distribu\u010dn\u00fd obvod by mal by\u0165 vybaven\u00fd vlastn\u00fdm poistkov\u00fdm ochrann\u00fdm zariaden\u00edm a ru\u010dn\u00fdm sp\u00edna\u010dom.<\/p>\n\n\n\n<p>6, verejn\u00fd rozvod energie a rozvod pr\u00edstrojov by mal by\u0165 ponechan\u00fd aspo\u0148 \u30fc n\u00e1hradn\u00e9ho obvodu.<\/p>\n\n\n\n<p>7, v\u00fdkonov\u00e9 sp\u00edna\u010de, rozvodn\u00e9 skrine, rozvodn\u00e9 skrine a in\u00e9 elektrick\u00e9 zariadenia by mali by\u0165 in\u0161talovan\u00e9 v s\u00falade s po\u017eiadavkami na ochranu miesta, nev\u00fdbu\u0161nos\u0165, in\u0161talovan\u00e9 mimo chaty, \u00farove\u0148 ochrany by nemala by\u0165 ni\u017e\u0161ia ako IP55; nev\u00fdbu\u0161n\u00e1 forma by mala by\u0165 zvolen\u00e1 typu Exd (e).<\/p>\n\n\n\n<p>8, nev\u00fdbu\u0161n\u00e1 anal\u00fdza osvetlenie chaty osvetlenie je v\u0161eobecne 250 ~ 300lx, s cie\u013eom u\u013eah\u010di\u0165 prev\u00e1dzku a \u00fadr\u017ebu. Mala by by\u0165 vybaven\u00e1 n\u00e1hodn\u00fdm svetlom. M\u00f4\u017eu sa pou\u017ei\u0165 svietidl\u00e1 s invertormi a bat\u00e9riami, pohotovostn\u00fd \u010das v\u00fdpadku pr\u00fadu nie je krat\u0161\u00ed ako 30 min, osvet\u013eovacie zariadenie by sa malo pou\u017ei\u0165 v nebezpe\u010dn\u00fdch priestoroch z\u00f3ny 1. Vyp\u00edna\u010d osvetlenia by mal by\u0165 nain\u0161talovan\u00fd ved\u013ea hlavn\u00fdch dver\u00ed mimo analytickej b\u00fadky, pri\u010dom by sa mal pou\u017ei\u0165 nev\u00fdbu\u0161n\u00fd vyp\u00edna\u010d. S cie\u013eom u\u013eah\u010di\u0165 prev\u00e1dzku no\u010dnej \u00fadr\u017eby by sa mala zabezpe\u010di\u0165 nev\u00fdbu\u0161n\u00e1 analytick\u00e1 b\u00fada mimo boxu na spracovanie vzoriek a z\u00e1bradlie plynovej f\u013ea\u0161e nad nev\u00fdbu\u0161n\u00fdm osvetlen\u00edm a mala by by\u0165 vybaven\u00e1 nev\u00fdbu\u0161n\u00fdm sp\u00edna\u010dom osvetlenia.<\/p>","protected":false},"excerpt":{"rendered":"<p>Exterior Facilities and Power Distribution Considerations for Explosion-Proof Analyzer Huts Most of the metal structure of the explosion-proof analysis hut is a non-standard product, the size of its size can be determined according to the number of analyzers, types, system complexity and operation and maintenance of space, and leave appropriate margins. I. Explosion-proof analyzer cabin [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_uag_custom_page_level_css":"","site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[8],"tags":[],"class_list":["post-2228","post","type-post","status-publish","format-standard","hentry","category-explosion-proof-equipment"],"uagb_featured_image_src":{"full":false,"thumbnail":false,"medium":false,"medium_large":false,"large":false,"1536x1536":false,"2048x2048":false,"trp-custom-language-flag":false},"uagb_author_info":{"display_name":"Joe","author_link":"https:\/\/led.amasly.com\/sk\/author\/jacklin\/"},"uagb_comment_info":0,"uagb_excerpt":"Exterior Facilities and Power Distribution Considerations for Explosion-Proof Analyzer Huts Most of the metal structure of the explosion-proof analysis hut is a non-standard product, the size of its size can be determined according to the number of analyzers, types, system complexity and operation and maintenance of space, and leave appropriate margins. I. Explosion-proof analyzer cabin&hellip;","_links":{"self":[{"href":"https:\/\/led.amasly.com\/sk\/wp-json\/wp\/v2\/posts\/2228","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/led.amasly.com\/sk\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/led.amasly.com\/sk\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/led.amasly.com\/sk\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/led.amasly.com\/sk\/wp-json\/wp\/v2\/comments?post=2228"}],"version-history":[{"count":2,"href":"https:\/\/led.amasly.com\/sk\/wp-json\/wp\/v2\/posts\/2228\/revisions"}],"predecessor-version":[{"id":2288,"href":"https:\/\/led.amasly.com\/sk\/wp-json\/wp\/v2\/posts\/2228\/revisions\/2288"}],"wp:attachment":[{"href":"https:\/\/led.amasly.com\/sk\/wp-json\/wp\/v2\/media?parent=2228"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/led.amasly.com\/sk\/wp-json\/wp\/v2\/categories?post=2228"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/led.amasly.com\/sk\/wp-json\/wp\/v2\/tags?post=2228"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}