{"id":2151,"date":"2025-03-02T16:19:37","date_gmt":"2025-03-02T08:19:37","guid":{"rendered":"https:\/\/led.amasly.com\/?p=2151"},"modified":"2025-03-06T23:06:18","modified_gmt":"2025-03-06T15:06:18","slug":"usporiadanie-a-ochrana-proti-vybuchu-v-prevadzkach-a-skladoch-s-nebezpecenstvom-vybuchu","status":"publish","type":"post","link":"https:\/\/led.amasly.com\/sk\/zariadenia-odolne-proti-vybuchu\/usporiadanie-a-ochrana-proti-vybuchu-v-prevadzkach-a-skladoch-s-nebezpecenstvom-vybuchu\/","title":{"rendered":"Usporiadanie a ochrana proti v\u00fdbuchu v prev\u00e1dzkach a skladoch s nebezpe\u010denstvom v\u00fdbuchu"},"content":{"rendered":"<h1 class=\"wp-block-heading has-text-align-center\"><strong>Usporiadanie a ochrana proti v\u00fdbuchu v prev\u00e1dzkach a skladoch s nebezpe\u010denstvom v\u00fdbuchu<\/strong><strong><\/strong><\/h1>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Usporiadanie a ochrana proti v\u00fdbuchu s\u00edl a skladov s nebezpe\u010denstvom v\u00fdbuchu<\/strong><strong><\/strong><\/h2>\n\n\n\n<h2 class=\"wp-block-heading\">I. V\u0161eobecn\u00e9 usporiadanie<\/h2>\n\n\n\n<div class=\"wp-block-uagb-image uagb-block-82dca846 wp-block-uagb-image--layout-default wp-block-uagb-image--effect-static wp-block-uagb-image--align-none\"><figure class=\"wp-block-uagb-image__figure\"><a class=\"\" href=\"https:\/\/led.amasly.com\/sk\/\" target=\"\" rel=\"noopener\"><img decoding=\"async\" srcset=\"https:\/\/led.amasly.com\/wp-content\/uploads\/2025\/03\/\u56fe\u724722.png 749w, https:\/\/led.amasly.com\/wp-content\/uploads\/2025\/03\/\u56fe\u724722-300x200.png 300w\" sizes=\"auto, (max-width: 480px) 150px\" src=\"https:\/\/led.amasly.com\/wp-content\/uploads\/2025\/03\/\u56fe\u724722.png\" alt=\"\" class=\"uag-image-2152\" width=\"749\" height=\"500\" title=\"\u56fe\u724722\" loading=\"lazy\" role=\"img\"><\/a><\/figure><\/div>\n\n\n\n<p class=\"wp-block-paragraph\">1. Zariadenie triedy A, B s rizikom v\u00fdbuchu, sklad by mal by\u0165 zriaden\u00fd samostatne a mal by by\u0165 otvoren\u00fd alebo polootvoren\u00fd, jeho nosn\u00e1 kon\u0161trukcia by mala by\u0165 \u017eelezobet\u00f3nov\u00e1 alebo oce\u013eov\u00e1 r\u00e1mov\u00e1, radov\u00e1 kon\u0161trukcia.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">2. Usporiadanie zariadenia s nebezpe\u010denstvom v\u00fdbuchu by malo by\u0165 prednostne obd\u013a\u017enikov\u00e9 a prevl\u00e1daj\u00faci smer vetra by mal by\u0165 kolm\u00fd alebo pod uhlom najmenej 45\u00b0, aby sa \u00fa\u010dinne vyu\u017eil prenikaj\u00faci vietor na rozpt\u00fdlenie v\u00fdbu\u0161n\u00fdch plynov v horsk\u00fdch oblastiach, mali by sa usporiada\u0165 na n\u00e1veternej strane svahu a na dobre vetran\u00fdch miestach.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">3. nev\u00fdbu\u0161n\u00fd z\u00e1vod by mal by\u0165 zriaden\u00fd oddelene, napr\u00edklad mus\u00ed by\u0165 pri\u013eahl\u00fd k nev\u00fdbu\u0161n\u00e9mu z\u00e1vodu, len z jednej strany pri\u013eahl\u00fd a medzi dvoma protipo\u017eiarnymi stenami alebo nev\u00fdbu\u0161nou stenou oddelen\u00fd. Pri\u013eahl\u00e9 dva z\u00e1vody by nemali by\u0165 priamo spojen\u00e9 s dverami, aby sa zabr\u00e1nilo n\u00e1razu r\u00e1zovej vlny v\u00fdbuchu.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>II. P\u00f4dorys a priestorov\u00e9 usporiadanie<\/strong><strong><\/strong><\/h2>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>1. Hlavn\u00e1 riadiaca miestnos\u0165 a ved\u013eaj\u0161ia riadiaca miestnos\u0165<\/strong><strong><\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">(1) V\u0161eobecn\u00fd dispe\u010ding prev\u00e1dzok s nebezpe\u010denstvom v\u00fdbuchu triedy A a B sa zria\u010fuje samostatne.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">(2) Existuje nebezpe\u010denstvo v\u00fdbuchu A, B trieda rastl\u00edn sub-riadiaca miestnos\u0165 by mala by\u0165 zriaden\u00e1 nez\u00e1visle, ke\u010f sa zriadi v bl\u00edzkosti vonkaj\u0161ej steny, by mala by\u0165 pou\u017eit\u00e1 oh\u0148ovzdorn\u00e1 hranica nie menej ako 3,00h po\u017eiarna deliaca stena a in\u00e9 \u010dasti oddelenia.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>2. Oblasti s nebezpe\u010denstvom v\u00fdbuchu<\/strong><strong><\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">(1) Existuje riziko v\u00fdbuchu v\u00fdrobn\u00fdch \u010dast\u00ed A, B, je vhodn\u00e9, aby boli usporiadan\u00e9 v jednopodla\u017enom z\u00e1vode pri vonkaj\u0161ej stene zariadenia na zn\u00ed\u017eenie tlaku alebo vo viacpodla\u017enom z\u00e1vode na najvy\u0161\u0161om poschod\u00ed pri vonkaj\u0161ej stene zariadenia na zn\u00ed\u017eenie tlaku v bl\u00edzkosti.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">(2) V nosn\u00edkoch, st\u013apoch a in\u00fdch hlavn\u00fdch nosn\u00fdch prvkoch zariadenia by sa nemalo vyskytova\u0165 riziko v\u00fdbuchu.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">(3) Schodisk\u00e1, vonkaj\u0161ie schodisk\u00e1 alebo priestory s nebezpe\u010denstvom v\u00fdbuchu v oblasti s nebezpe\u010denstvom v\u00fdbuchu by mali by\u0165 vybaven\u00e9 dvern\u00fdmi vedrami a in\u00fdmi ochrann\u00fdmi opatreniami. Deliaca stena dvernej n\u00e1sypky mus\u00ed by\u0165 oh\u0148ovzdorn\u00e1 deliaca stena s hranicou po\u017eiarnej odolnosti najmenej 2,00 h a dvere musia prija\u0165 oh\u0148ovzdorn\u00e9 dvere triedy A a musia by\u0165 zo\u0161ikmen\u00e9 s dverami schodiska.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>3. Zariadenie emituj\u00face hor\u013eav\u00e9 plyny, hor\u013eav\u00e9 v\u00fdpary<\/strong><strong><\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">(1) V pr\u00edpade zariaden\u00ed kateg\u00f3rie A, ktor\u00e9 emituj\u00fa \u013eah\u0161ie hor\u013eav\u00e9 plyny a hor\u013eav\u00e9 pary ako vzduch, je vhodn\u00e9 pou\u017ei\u0165 \u013eahk\u00e9 stre\u0161n\u00e9 panely ako od\u013eah\u010dovaciu plochu. Strecha by mala by\u0165 \u010do najploch\u0161ia a bez m\u0155tvych priestorov a horn\u00fd priestor zariadenia by mal by\u0165 dobre vetran\u00fd.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">(2) Zariadenia kateg\u00f3rie A emituj\u00face \u0165a\u017e\u0161ie hor\u013eav\u00e9 plyny a hor\u013eav\u00e9 pary ako vzduch a zariadenia kateg\u00f3rie B s nebezpe\u010denstvom v\u00fdbuchu prachu a vl\u00e1kien musia sp\u013a\u0148a\u0165 tieto ustanovenia:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Mali by sa pou\u017e\u00edva\u0165 neiskriace podlahy. Pri pou\u017eit\u00ed izola\u010dn\u00fdch materi\u00e1lov na celkov\u00fd povrch sa musia prija\u0165 antistatick\u00e9 opatrenia.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Vn\u00fatorn\u00e9 povrchy zariaden\u00ed, ktor\u00e9 uvo\u013e\u0148uj\u00fa hor\u013eav\u00fd prach a vl\u00e1kna, by mali by\u0165 rovn\u00e9, hladk\u00e9 a \u013eahko \u010distite\u013en\u00e9.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Nie je vhodn\u00e9 zriadi\u0165 \u017e\u013eab v z\u00e1vode, ak je potrebn\u00e9 ho zriadi\u0165, kryt by mal by\u0165 tesn\u00fd, \u017e\u013eab by mal prija\u0165 \u00fa\u010dinn\u00e9 opatrenia na zabr\u00e1nenie hromadeniu hor\u013eav\u00fdch plynov, hor\u013eav\u00fdch v\u00fdparov a prachov, vl\u00e1kien v \u017e\u013eabe a mal by by\u0165 utesnen\u00fd oh\u0148ovzdorn\u00fdmi materi\u00e1lmi na spojen\u00ed so susedn\u00fdm z\u00e1vodom.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>4. Z\u00e1vody a sklady, ktor\u00e9 pou\u017e\u00edvaj\u00fa, vyr\u00e1baj\u00fa alebo skladuj\u00fa kvapaliny kateg\u00f3ri\u00ed A, B a C<\/strong><strong><\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">(1) Potrubia a kanaliz\u00e1cie prev\u00e1dzok, ktor\u00e9 pou\u017e\u00edvaj\u00fa a produkuj\u00fa kvapaliny kateg\u00f3ri\u00ed A, B a C, nesm\u00fa by\u0165 prepojen\u00e9 s potrubiami a kanaliz\u00e1ciami susedn\u00fdch prev\u00e1dzok a kanaliz\u00e1cie musia by\u0165 vybaven\u00e9 lapa\u010dmi tukov.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">(2) Sklady kvapal\u00edn kateg\u00f3ri\u00ed A, B a C musia by\u0165 vybaven\u00e9 zariadeniami na zabr\u00e1nenie rozptylu kvapal\u00edn. Sklady predmetov, ktor\u00e9 po navlh\u010den\u00ed horia a vybuchuj\u00fa, by mali by\u0165 vybaven\u00e9 opatreniami na zabr\u00e1nenie impregn\u00e1cie vodou.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>5. Podzemn\u00e9, polosuter\u00e9nne<\/strong><strong><\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">(1) V\u00fdrobn\u00e9 miesta triedy A a B by nemali by\u0165 umiestnen\u00e9 pod zemou alebo \u010diasto\u010dne pod zemou.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">(2) Sklady kateg\u00f3rie A a B by tie\u017e nemali by\u0165 umiestnen\u00e9 pod zemou alebo \u010diasto\u010dne pod zemou.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>III. Od\u013eah\u010denie tlaku<\/strong><strong><\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">1. Zariadenie s nebezpe\u010denstvom v\u00fdbuchu alebo \u010dasti zariadenia s nebezpe\u010denstvom v\u00fdbuchu by mali by\u0165 vybaven\u00e9 zariadeniami na zn\u00ed\u017eenie tlaku.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">2. Pri v\u00fdbuchu bezpe\u010dnostn\u00e9ho skla a in\u00fdch materi\u00e1lov, ktor\u00e9 nevytv\u00e1raj\u00fa ostr\u00e9 \u00falomky, by sa mali pou\u017ei\u0165 \u013eahk\u00e9 stre\u0161n\u00e9 panely, \u013eahk\u00e9 steny a \u013eahko uvo\u013eni\u0165 tlak dver\u00ed, okien at\u010f.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">3. Zariadenia na zni\u017eovanie tlaku by sa mali zria\u010fova\u0165 tak, aby sa vyh\u00fdbali husto ob\u00fdvan\u00fdm miestam a hlavn\u00fdm dopravn\u00fdm komunik\u00e1ci\u00e1m, a mali by sa nach\u00e1dza\u0165 v bl\u00edzkosti \u010dast\u00ed ohrozen\u00fdch v\u00fdbuchom.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">4. Hmotnos\u0165 \u013eahk\u00fdch stre\u0161n\u00fdch panelov a stien pou\u017e\u00edvan\u00fdch ako zariadenia na zn\u00ed\u017eenie tlaku by nemala by\u0165 v\u00e4\u010d\u0161ia ako 60 kg\/\u33a1. 5. Na stre\u0161n\u00fdch zariadeniach na od\u013eah\u010denie tlaku by sa mali prija\u0165 opatrenia proti hromadeniu snehu a \u013eadu.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">5. V pr\u00edpade zariaden\u00ed kateg\u00f3rie A, ktor\u00e9 emituj\u00fa \u013eah\u0161ie hor\u013eav\u00e9 plyny a pary ako vzduch, je vhodn\u00e9 pou\u017ei\u0165 \u013eahk\u00e9 stre\u0161n\u00e9 panely ako od\u013eah\u010dovaciu plochu. Strecha by mala by\u0165 \u010do najploch\u0161ia, bez m\u0155tvych priestorov, a horn\u00fd priestor zariadenia by mal by\u0165 dobre vetran\u00fd.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>IV. V\u00fdpo\u010det od\u013eah\u010dovacej oblasti<\/strong><strong><\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Vzorec pre v\u00fdpo\u010det od\u013eah\u010dovacej plochy:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">A=10CV2\/3 A - od\u013eah\u010dovacia plocha (\u33a1); V - objem zariadenia (m\u00b3); C - od\u013eah\u010dovac\u00ed pomer<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">(1) Pomer d\u013a\u017eky a priemeru: najdlh\u0161\u00ed rozmer geometrick\u00fdch rozmerov roviny stavby a jej prie\u010dneho obvodu v\u00fdrobku a 4,0-n\u00e1sobok pomeru plochy prierezu stavby.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">(2) Ak je pomer d\u013a\u017eky a priemeru zariadenia v\u00e4\u010d\u0161\u00ed ako 3, je vhodn\u00e9 rozdeli\u0165 budovu na viacero v\u00fdpo\u010dtov\u00fdch sekci\u00ed s pomerom d\u013a\u017eky a priemeru, ktor\u00fd nie je v\u00e4\u010d\u0161\u00ed ako 3, a spolo\u010dn\u00e1 sekcia v ka\u017edej v\u00fdpo\u010dtovej sekcii sa nesmie pou\u017ei\u0165 ako oblas\u0165 od\u013eah\u010denia tlaku.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>V<\/strong><strong>, ako dobre vykona\u0165 opatrenia na ochranu proti po\u017eiaru a v\u00fdbuchu pri vysok\u00fdch teplot\u00e1ch<\/strong><strong><\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Sklady kateg\u00f3rie A a B s\u00fa sklady, v ktor\u00fdch sa skladuj\u00fa nebezpe\u010dn\u00e9 chemik\u00e1lie a v ktor\u00fdch sa na zaistenie bezpe\u010dnosti vy\u017eaduj\u00fa opatrenia proti teplu, vode, oh\u0148u a v\u00fdbuchu.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">1. Opatrenia proti vysok\u00fdm teplot\u00e1m: V skladoch kateg\u00f3rie A a B by sa malo zabezpe\u010di\u0165, aby teplota neprekro\u010dila po\u017eiadavky na skladovanie nebezpe\u010dn\u00fdch chemik\u00e1li\u00ed. M\u00f4\u017eu sa prija\u0165 tieto opatrenia: in\u0161tal\u00e1cia klimatiza\u010dn\u00fdch alebo ventila\u010dn\u00fdch syst\u00e9mov vo vn\u00fatri skladu na regul\u00e1ciu teploty; izol\u00e1cia skladu tepelnoizola\u010dn\u00fdmi alebo tepelnoizola\u010dn\u00fdmi materi\u00e1lmi; pravideln\u00e1 kontrola a \u00fadr\u017eba chladiaceho zariadenia, aby sa zabezpe\u010dila jeho spr\u00e1vna funk\u010dnos\u0165.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">2. Hydroizola\u010dn\u00e9 opatrenia: Sklady kateg\u00f3rie A a B by mali by\u0165 hydroizolovan\u00e9, aby sa zabr\u00e1nilo vniknutiu da\u017e\u010fovej vody alebo in\u00fdch kvapal\u00edn do skladu a ich \u00faniku alebo kontamin\u00e1cii chemik\u00e1liami. Mo\u017eno prija\u0165 tieto opatrenia: skontrolova\u0165 utesnenie striech a stien skladu a opravi\u0165 v\u0161etky netesnosti alebo priesaky; zabezpe\u010di\u0165, aby bol odvod\u0148ovac\u00ed syst\u00e9m bez prek\u00e1\u017eok a aby sa odtoky a potrubia v\u010das \u010distili; a v pr\u00edpade potreby nain\u0161talova\u0165 vodotesn\u00e9 n\u00e1tery alebo obklady.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">3. Protipo\u017eiarne opatrenia: Sklady kateg\u00f3rie A a B by mali by\u0165 vybaven\u00e9 protipo\u017eiarnymi zariadeniami, aby sa minimalizovalo riziko vzniku po\u017eiaru. M\u00f4\u017eu sa prija\u0165 tieto opatrenia: in\u0161tal\u00e1cia po\u017eiarneho poplachov\u00e9ho syst\u00e9mu na v\u010dasn\u00e9 zistenie a nahl\u00e1senie po\u017eiaru; vybavenie hasiacimi pr\u00edstrojmi, penov\u00fdmi hasiacimi syst\u00e9mami alebo such\u00fdmi pr\u00e1\u0161kov\u00fdmi hasiacimi syst\u00e9mami a in\u00fdmi protipo\u017eiarnymi zariadeniami; pravideln\u00e1 kontrola a \u00fadr\u017eba t\u00fdchto zariaden\u00ed s cie\u013eom zabezpe\u010di\u0165 ich norm\u00e1lnu prev\u00e1dzku; a udr\u017eiavanie vo\u013en\u00fdch uli\u010diek v sklade s cie\u013eom u\u013eah\u010di\u0165 evaku\u00e1ciu.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">4. Opatrenia proti v\u00fdbuchu: V skladoch kateg\u00f3rie A a B sa m\u00f4\u017eu vyskytova\u0165 hor\u013eav\u00e9 a v\u00fdbu\u0161n\u00e9 l\u00e1tky a na ochranu bezpe\u010dnosti person\u00e1lu a zariaden\u00ed je potrebn\u00e9 prija\u0165 nev\u00fdbu\u0161n\u00e9 opatrenia. Mo\u017eno prija\u0165 tieto opatrenia: pou\u017e\u00edva\u0165 nev\u00fdbu\u0161n\u00e9 elektrick\u00e9 zariadenia, ako s\u00fa nev\u00fdbu\u0161n\u00e9 sp\u00edna\u010de a nev\u00fdbu\u0161n\u00e9 lampy; zabezpe\u010di\u0165, aby elektrick\u00e9 zariadenia v sklade sp\u013a\u0148ali po\u017eiadavky na nev\u00fdbu\u0161nos\u0165; obmedzi\u0165 vznik otvoren\u00e9ho oh\u0148a, statickej elektriny a iskier; a poskytn\u00fa\u0165 vhodn\u00e9 nev\u00fdbu\u0161n\u00e9 osobn\u00e9 ochrann\u00e9 prostriedky.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">5. Pravideln\u00e1 kontrola a \u00fadr\u017eba: Pravidelne kontrolujte \u00fa\u010dinnos\u0165 opatren\u00ed proti teplu, vode, po\u017eiaru a v\u00fdbuchu v skladoch kateg\u00f3rie A a B a vykon\u00e1vajte potrebn\u00fa \u00fadr\u017ebu a opravy. Zabezpe\u010dte neporu\u0161enos\u0165 a norm\u00e1lnu prev\u00e1dzku ochrann\u00fdch zariaden\u00ed a vybavenia.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">6. \u0160kolenie a zvy\u0161ovanie povedomia zamestnancov: \u0160kolenie zamestnancov skladu v oblasti nakladania s nebezpe\u010dn\u00fdmi chemick\u00fdmi l\u00e1tkami a bezpe\u010dnej prev\u00e1dzky, aby boli obozn\u00e1men\u00ed s pr\u00edslu\u0161n\u00fdmi ochrann\u00fdmi opatreniami a opatreniami reakcie v pr\u00edpade mimoriadnej udalosti. Zvy\u0161ujte povedomie zamestnancov o d\u00f4le\u017eitosti bezpe\u010dnosti a spr\u00e1vnom pou\u017e\u00edvan\u00ed ochrann\u00fdch prostriedkov.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Prijat\u00edm uveden\u00fdch opatren\u00ed mo\u017eno minimalizova\u0165 rizik\u00e1 tepla, vody, po\u017eiaru a v\u00fdbuchu v skladoch kateg\u00f3rie A a B a zabezpe\u010di\u0165 bezpe\u010dn\u00e9 skladovanie a nakladanie s nebezpe\u010dn\u00fdmi chemick\u00fdmi l\u00e1tkami. K\u013e\u00fa\u010dom k prevencii neh\u00f4d je pritom pravideln\u00e1 \u00fadr\u017eba a \u0161kolenie zamestnancov. Konkr\u00e9tne ochrann\u00e9 opatrenia formulujte pod\u013ea aktu\u00e1lnej situ\u00e1cie v spojen\u00ed s odborn\u00fdmi a technick\u00fdmi usmerneniami a pr\u00e1vnymi a regula\u010dn\u00fdmi po\u017eiadavkami.<\/p>","protected":false},"excerpt":{"rendered":"<p>Arrangement and explosion protection of explosion-hazardous plants and warehouses Layout and explosion protection of explosion-hazardous silos and warehouses I. General layout 1. Explosion risk of Class A, B plant, warehouse should be set up independently, and should be open or semi-open, its load-bearing structure should be reinforced concrete or steel frame, row structure. 2. explosion-hazardous [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_uag_custom_page_level_css":"","site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[8],"tags":[],"class_list":["post-2151","post","type-post","status-publish","format-standard","hentry","category-explosion-proof-equipment"],"uagb_featured_image_src":{"full":false,"thumbnail":false,"medium":false,"medium_large":false,"large":false,"1536x1536":false,"2048x2048":false,"trp-custom-language-flag":false},"uagb_author_info":{"display_name":"Joe","author_link":"https:\/\/led.amasly.com\/sk\/author\/jacklin\/"},"uagb_comment_info":0,"uagb_excerpt":"Arrangement and explosion protection of explosion-hazardous plants and warehouses Layout and explosion protection of explosion-hazardous silos and warehouses I. General layout 1. Explosion risk of Class A, B plant, warehouse should be set up independently, and should be open or semi-open, its load-bearing structure should be reinforced concrete or steel frame, row structure. 2. explosion-hazardous&hellip;","_links":{"self":[{"href":"https:\/\/led.amasly.com\/sk\/wp-json\/wp\/v2\/posts\/2151","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/led.amasly.com\/sk\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/led.amasly.com\/sk\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/led.amasly.com\/sk\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/led.amasly.com\/sk\/wp-json\/wp\/v2\/comments?post=2151"}],"version-history":[{"count":2,"href":"https:\/\/led.amasly.com\/sk\/wp-json\/wp\/v2\/posts\/2151\/revisions"}],"predecessor-version":[{"id":2305,"href":"https:\/\/led.amasly.com\/sk\/wp-json\/wp\/v2\/posts\/2151\/revisions\/2305"}],"wp:attachment":[{"href":"https:\/\/led.amasly.com\/sk\/wp-json\/wp\/v2\/media?parent=2151"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/led.amasly.com\/sk\/wp-json\/wp\/v2\/categories?post=2151"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/led.amasly.com\/sk\/wp-json\/wp\/v2\/tags?post=2151"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}