{"id":1589,"date":"2024-12-28T14:34:33","date_gmt":"2024-12-28T06:34:33","guid":{"rendered":"https:\/\/led.amasly.com\/?p=1589"},"modified":"2024-12-28T14:52:01","modified_gmt":"2024-12-28T06:52:01","slug":"the-relevant-requirements-for-grounding-of-explosion-proof-lamps-and-electrical-equipment-in-explosive-hazardous-environments","status":"publish","type":"post","link":"https:\/\/led.amasly.com\/sk\/explosion-proof-equipment\/the-relevant-requirements-for-grounding-of-explosion-proof-lamps-and-electrical-equipment-in-explosive-hazardous-environments\/","title":{"rendered":"Pr\u00edslu\u0161n\u00e9 po\u017eiadavky na uzemnenie nev\u00fdbu\u0161n\u00fdch svietidiel a elektrick\u00fdch zariaden\u00ed v prostred\u00ed s nebezpe\u010denstvom v\u00fdbuchu."},"content":{"rendered":"<p class=\"has-medium-font-size\">V prostrediach s nebezpe\u010denstvom v\u00fdbuchu by mali by\u0165 uzemnen\u00e9 vystaven\u00e9 nenabit\u00e9 kovov\u00e9 \u010dasti elektrick\u00fdch zariaden\u00ed, ako s\u00fa kovov\u00e9 kryty, kovov\u00e9 r\u00e1my, zariadenia in\u0161talovan\u00e9 na uzemnen\u00fdch kovov\u00fdch kon\u0161trukci\u00e1ch, kovov\u00e9 potrubia a ich pr\u00edslu\u0161enstvo, ochrann\u00e9 k\u00e1blov\u00e9 kan\u00e1ly a kovov\u00e9 pl\u00e1\u0161te k\u00e1blov at\u010f. V mnoh\u00fdch norm\u00e1ch s\u00fa jasne stanoven\u00e9 predpisy t\u00fdkaj\u00face sa po\u017eiadaviek na uzemnenie elektrick\u00fdch zariaden\u00ed v prostred\u00ed s nebezpe\u010denstvom v\u00fdbuchu. <\/p>\n\n\n\n<div class=\"wp-block-uagb-image uagb-block-5d6c6f99 wp-block-uagb-image--layout-default wp-block-uagb-image--effect-static wp-block-uagb-image--align-none\"><figure class=\"wp-block-uagb-image__figure\"><img decoding=\"async\" srcset=\"https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/12\/grounding-of-explosion-proof-lamps.png ,https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/12\/grounding-of-explosion-proof-lamps.png 780w, https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/12\/grounding-of-explosion-proof-lamps.png 360w\" sizes=\"auto, (max-width: 480px) 150px\" src=\"https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/12\/grounding-of-explosion-proof-lamps.png\" alt=\"\" class=\"uag-image-1590\" width=\"469\" height=\"305\" title=\"uzemnenie nev\u00fdbu\u0161n\u00fdch svietidiel\" loading=\"lazy\" role=\"img\"><\/figure><\/div>\n\n\n\n<p class=\"has-medium-font-size\">Nastavenie uzem\u0148ovacieho vodi\u010da pre elektrick\u00e9 zariadenia by sa malo rie\u0161i\u0165 odli\u0161ne pod\u013ea r\u00f4znych nebezpe\u010dn\u00fdch oblast\u00ed a typov elektrick\u00fdch zariaden\u00ed. Kovov\u00e9 kryty v\u0161etk\u00fdch elektrick\u00fdch zariaden\u00ed vo v\u00fdbu\u0161nom prostred\u00ed bez oh\u013eadu na to, \u010di s\u00fa in\u0161talovan\u00e9 na uzemnen\u00fdch kovov\u00fdch kon\u0161trukci\u00e1ch, by mali by\u0165 uzemnen\u00e9. Pr\u00edslu\u0161n\u00e9 po\u017eiadavky s\u00fa nasledovn\u00e9: <\/p>\n\n\n\n<p class=\"has-medium-font-size\">1) V\u0161etky elektrick\u00e9 zariadenia vo v\u00fdbu\u0161nom prostred\u00ed z\u00f3ny 1, z\u00f3ny 20 a z\u00f3ny 21, ako aj v\u0161etky elektrick\u00e9 zariadenia okrem svietidiel vo v\u00fdbu\u0161nom prostred\u00ed z\u00f3ny 2 a z\u00f3ny 22 by mali ma\u0165 pridan\u00e9 vyhraden\u00e9 uzem\u0148ovacie vodi\u010de. Pozn\u00e1mka: Ak je vyhraden\u00fd uzem\u0148ovac\u00ed vodi\u010d ulo\u017een\u00fd v tom istom ochrannom potrub\u00ed ako f\u00e1zov\u00fd vodi\u010d, mal by ma\u0165 rovnak\u00fa \u00farove\u0148 izol\u00e1cie ako f\u00e1zov\u00fd vodi\u010d. <\/p>\n\n\n\n<p class=\"has-medium-font-size\">2) Pri svietidl\u00e1ch vo v\u00fdbu\u0161nom prostred\u00ed z\u00f3ny 2 a z\u00f3ny 22 mo\u017eno ako uzem\u0148ovac\u00ed vodi\u010d pou\u017ei\u0165 spo\u013eahliv\u00fd kovov\u00fd potrubn\u00fd syst\u00e9m elektrick\u00e9ho pripojenia, ale nemo\u017eno pou\u017ei\u0165 potrubia na prepravu v\u00fdbu\u0161n\u00fdch nebezpe\u010dn\u00fdch l\u00e1tok. <\/p>\n\n\n\n<p class=\"has-medium-font-size\">3) Vyhraden\u00e9 uzem\u0148ovacie vodi\u010de pre elektrick\u00e9 zariadenia a svietidl\u00e1 by mali by\u0165 samostatne pripojen\u00e9 k hlavn\u00e9mu uzem\u0148ova\u010du (sieti) a pracovn\u00fd nulov\u00fd vodi\u010d v elektrickom obvode by sa nemal pou\u017e\u00edva\u0165 ako ochrann\u00fd uzem\u0148ovac\u00ed vodi\u010d. <\/p>\n\n\n\n<p class=\"has-medium-font-size\">4) Na spojenie medzi elektrick\u00fdm zariaden\u00edm v prostred\u00ed s nebezpe\u010denstvom v\u00fdbuchu a uzem\u0148ovac\u00edm vodi\u010dom by sa mal prednostne pou\u017ei\u0165 viacvl\u00e1knov\u00fd pru\u017en\u00fd dr\u00f4t s minim\u00e1lnym prierezom meden\u00e9ho dr\u00f4tu najmenej 4 mm\u00b2. Na \u010dastiach n\u00e1chyln\u00fdch na mechanick\u00e9 po\u0161kodenie by sa mali nain\u0161talova\u0165 ochrann\u00e9 trubice. <\/p>\n\n\n\n<p class=\"has-medium-font-size\">5) Ak s\u00fa do elektrick\u00e9ho zariadenia zaveden\u00e9 pancierov\u00e9 k\u00e1ble, uzem\u0148ovac\u00ed vodi\u010d by mal by\u0165 pripojen\u00fd k uzem\u0148ovacej skrutke vo vn\u00fatri zariadenia; oce\u013eov\u00e1 p\u00e1ska a kovov\u00fd kryt by mali by\u0165 pripojen\u00e9 k vonkaj\u0161ej uzem\u0148ovacej skrutke zariadenia. <\/p>\n\n\n\n<p class=\"has-medium-font-size\">6) Skrutky pou\u017e\u00edvan\u00e9 na uzemnenie alebo nulov\u00e9 spojenie v prostred\u00ed s nebezpe\u010denstvom v\u00fdbuchu by mali ma\u0165 zariadenia proti uvo\u013eneniu; pred utiahnut\u00edm uzem\u0148ovacieho vodi\u010da by sa mali uzem\u0148ovacie svorky a spojovacie prvky natrie\u0165 mazivom z energetickej zmesi. <\/p>\n\n\n\n<p class=\"has-medium-font-size\">Existuje mnoho po\u017eiadaviek na uzemnenie elektrick\u00fdch zariaden\u00ed v prostred\u00ed s nebezpe\u010denstvom v\u00fdbuchu. V procese n\u00e1vrhu a in\u0161tal\u00e1cie by sa okrem splnenia uveden\u00fdch po\u017eiadaviek mali dodr\u017eiava\u0165 aj pr\u00edslu\u0161n\u00e9 normy.<\/p>","protected":false},"excerpt":{"rendered":"<p>In explosive hazardous environments, the exposed non-charged metal parts of electrical equipment such as the metal enclosures, metal frameworks, equipment installed on grounded metal structures, metal piping and its fittings, cable protection conduits, and the metal sheaths of cables, etc., should all be grounded. Many standards have made clear regulations on the grounding requirements for [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":1590,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_uag_custom_page_level_css":"","site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"disabled","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[8],"tags":[],"class_list":["post-1589","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-explosion-proof-equipment"],"uagb_featured_image_src":{"full":["https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/12\/grounding-of-explosion-proof-lamps.png",469,305,false],"thumbnail":["https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/12\/grounding-of-explosion-proof-lamps-150x150.png",150,150,true],"medium":["https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/12\/grounding-of-explosion-proof-lamps-300x195.png",300,195,true],"medium_large":["https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/12\/grounding-of-explosion-proof-lamps.png",469,305,false],"large":["https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/12\/grounding-of-explosion-proof-lamps.png",469,305,false],"1536x1536":["https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/12\/grounding-of-explosion-proof-lamps.png",469,305,false],"2048x2048":["https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/12\/grounding-of-explosion-proof-lamps.png",469,305,false],"trp-custom-language-flag":["https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/12\/grounding-of-explosion-proof-lamps.png",18,12,false]},"uagb_author_info":{"display_name":"Joe","author_link":"https:\/\/led.amasly.com\/sk\/author\/jacklin\/"},"uagb_comment_info":0,"uagb_excerpt":"In explosive hazardous environments, the exposed non-charged metal parts of electrical equipment such as the metal enclosures, metal frameworks, equipment installed on grounded metal structures, metal piping and its fittings, cable protection conduits, and the metal sheaths of cables, etc., should all be grounded. Many standards have made clear regulations on the grounding requirements for&hellip;","_links":{"self":[{"href":"https:\/\/led.amasly.com\/sk\/wp-json\/wp\/v2\/posts\/1589","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/led.amasly.com\/sk\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/led.amasly.com\/sk\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/led.amasly.com\/sk\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/led.amasly.com\/sk\/wp-json\/wp\/v2\/comments?post=1589"}],"version-history":[{"count":1,"href":"https:\/\/led.amasly.com\/sk\/wp-json\/wp\/v2\/posts\/1589\/revisions"}],"predecessor-version":[{"id":1591,"href":"https:\/\/led.amasly.com\/sk\/wp-json\/wp\/v2\/posts\/1589\/revisions\/1591"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/led.amasly.com\/sk\/wp-json\/wp\/v2\/media\/1590"}],"wp:attachment":[{"href":"https:\/\/led.amasly.com\/sk\/wp-json\/wp\/v2\/media?parent=1589"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/led.amasly.com\/sk\/wp-json\/wp\/v2\/categories?post=1589"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/led.amasly.com\/sk\/wp-json\/wp\/v2\/tags?post=1589"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}