{"id":2114,"date":"2025-03-01T10:36:01","date_gmt":"2025-03-01T02:36:01","guid":{"rendered":"https:\/\/led.amasly.com\/?p=2114"},"modified":"2025-03-07T21:26:35","modified_gmt":"2025-03-07T13:26:35","slug":"explosion-proof-plugging-parts-related-knowledge","status":"publish","type":"post","link":"https:\/\/led.amasly.com\/ro\/explosion-proof-equipment\/explosion-proof-plugging-parts-related-knowledge\/","title":{"rendered":"Cuno\u0219tin\u021be legate de piesele de conectare antideflagrante"},"content":{"rendered":"<h1 class=\"wp-block-heading has-text-align-center\"><strong>Cuno\u0219tin\u021be legate de piesele de conectare rezistente la explozii<\/strong><strong><\/strong><\/h1>\n\n\n\n<p>\u00cen zonele cu risc de incendiu \u0219i explozie din \u00eentreprinderile chimice, utilizarea echipamentelor electrice antiexplozie este o practic\u0103 obi\u0219nuit\u0103 pentru a controla eficient sc\u00e2nteile generate de echipamentele electrice, <strong>pentru a evita scurgerile de gaze combustibile din jur \u00een echipamentul electric din interiorul accidentului de explozie rapid\u0103.<\/strong><\/p>\n\n\n\n<div class=\"wp-block-uagb-image uagb-block-fc91cb39 wp-block-uagb-image--layout-default wp-block-uagb-image--effect-static wp-block-uagb-image--align-none\"><figure class=\"wp-block-uagb-image__figure\"><a class=\"\" href=\"https:\/\/led.amasly.com\/ro\/products\/\" target=\"\" rel=\"noopener\"><img decoding=\"async\" srcset=\"https:\/\/led.amasly.com\/wp-content\/uploads\/2025\/03\/lQLPJw3NPENT08fNAavNAoCw9InDO50DlrIHpHvJwwmpAA_640_427.png ,https:\/\/led.amasly.com\/wp-content\/uploads\/2025\/03\/lQLPJw3NPENT08fNAavNAoCw9InDO50DlrIHpHvJwwmpAA_640_427.png 780w, https:\/\/led.amasly.com\/wp-content\/uploads\/2025\/03\/lQLPJw3NPENT08fNAavNAoCw9InDO50DlrIHpHvJwwmpAA_640_427.png 360w\" sizes=\"auto, (max-width: 480px) 150px\" src=\"https:\/\/led.amasly.com\/wp-content\/uploads\/2025\/03\/lQLPJw3NPENT08fNAavNAoCw9InDO50DlrIHpHvJwwmpAA_640_427.png\" alt=\"\" class=\"uag-image-2115\" width=\"640\" height=\"427\" title=\"lQLPJw3NPENT08fNAavNAoCw9InDO50DlrIHpHvJwwmpAA_640_427\" loading=\"lazy\" role=\"img\"><\/a><\/figure><\/div>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Cerin\u021be generale pentru componentele principale ale echipamentelor antideflagrante<\/strong><strong><\/strong><\/h2>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>I. <\/strong><strong>Elemente de fixare<\/strong><strong><\/strong><\/h2>\n\n\n\n<p>1. Elementele de fixare trebuie s\u0103 aib\u0103 o rezisten\u021b\u0103 mecanic\u0103 suficient\u0103 pentru a nu cauza ruperea \u0219urubului la explozia proiectilului.<\/p>\n\n\n\n<p>2, elementele de fixare ar trebui s\u0103 fie anti-rugin\u0103, m\u0103suri de anti-\u00eenl\u0103n\u021buire pentru a se asigura c\u0103 clearance-ul suprafe\u021bei comune antideflagrante de tip plan.<\/p>\n\n\n\n<p>3, Atunci c\u00e2nd fixa\u021bi cu \u0219uruburi, dac\u0103 sunt utilizate \u0219aibe elastice pentru a preveni sl\u0103birea, aplatiza\u021bi \u0219aibele elastice \u0219i nu trebuie str\u00e2nse prea mult.<\/p>\n\n\n\n<p>4. Pentru a evita forfecarea \u0219uruburilor de fixare de c\u0103tre for\u021be externe, dimensiunile exterioare ale \u00eembin\u0103rilor capacului \u0219i ale \u00eenveli\u0219ului trebuie s\u0103 fie acelea\u0219i.<\/p>\n\n\n\n<p>5, pentru a fixa \u00een siguran\u021b\u0103, materialul \u0219uruburilor \u0219i al piuli\u021belor nu are voie s\u0103 utilizeze plastic sau aliaj u\u0219or \u0219i nu are voie s\u0103 ating\u0103 g\u0103urile de \u0219urub direct pe carcasa din plastic.<\/p>\n\n\n\n<p>6, ad\u00e2ncimea g\u0103urilor de \u0219urub impermeabile ar trebui s\u0103 se asigure c\u0103 \u0219urubul \u0219i g\u0103urile de \u0219urub dup\u0103 str\u00e2ngere, trebuie s\u0103 existe mai mult de 2 ori grosimea marginii filetului lamei de blocare.<\/p>\n\n\n\n<p>7. Grosimea \u00een jurul \u0219i la baza orificiului impermeabil al \u0219urubului nu trebuie s\u0103 fie mai mic\u0103 de o treime din diametrul \u0219urubului, dar cu o marj\u0103 de cel pu\u021bin 3,0 mm.<\/p>\n\n\n\n<p>8, procesul cu gaura de trecere sau structura trebuie s\u0103 p\u0103trund\u0103 \u00een cochilia g\u0103urilor de \u0219urub, ar trebui s\u0103 fie cilindrice sau filetate structur\u0103 antideflagrant pentru a o astupa, cap\u0103tul expus trebuie s\u0103 fie fixat permanent.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>II. <\/strong><strong>Dopuri<\/strong><strong><\/strong><\/h2>\n\n\n\n<div class=\"wp-block-uagb-image uagb-block-48bc53a7 wp-block-uagb-image--layout-default wp-block-uagb-image--effect-static wp-block-uagb-image--align-none\"><figure class=\"wp-block-uagb-image__figure\"><a class=\"\" href=\"https:\/\/led.amasly.com\/ro\/products\/\" target=\"\" rel=\"noopener\"><img decoding=\"async\" srcset=\"https:\/\/led.amasly.com\/wp-content\/uploads\/2025\/03\/lQLPKG8UenV9iEfNAcrNAx6wC5T38_mbSCwHpHk93yWmAA_798_458.png ,https:\/\/led.amasly.com\/wp-content\/uploads\/2025\/03\/lQLPKG8UenV9iEfNAcrNAx6wC5T38_mbSCwHpHk93yWmAA_798_458.png 780w, https:\/\/led.amasly.com\/wp-content\/uploads\/2025\/03\/lQLPKG8UenV9iEfNAcrNAx6wC5T38_mbSCwHpHk93yWmAA_798_458.png 360w\" sizes=\"auto, (max-width: 480px) 150px\" src=\"https:\/\/led.amasly.com\/wp-content\/uploads\/2025\/03\/lQLPKG8UenV9iEfNAcrNAx6wC5T38_mbSCwHpHk93yWmAA_798_458.png\" alt=\"\" class=\"uag-image-2116\" width=\"798\" height=\"458\" title=\"lQLPKG8UenV9iEfNAcrNAx6wC5T38_mbSCwHpHk93yWmAA_798_458\" loading=\"lazy\" role=\"img\"><\/a><\/figure><\/div>\n\n\n\n<p>Odat\u0103 cu lansarea oficial\u0103 a versiunii 2021 a standardului GB\/T3836, GB\/T 3836.2-2021 \u00eembog\u0103\u021be\u0219te cerin\u021bele pentru piesele de blocare Ex, iar diferen\u021bele fa\u021b\u0103 de GB 3836.2-2010 sunt dup\u0103 cum urmeaz\u0103:<\/p>\n\n\n\n<p>1.GB 3836.2-2010 Articolul 11 pentru \u201celemente de fixare, g\u0103uri aferente \u0219i piese de blocare\u201d, GB\/T 3836.2-2021 \u00een 11 a eliminat piesele de blocare, \u00een 13.8 dispozi\u021bii separate ale cerin\u021belor pieselor de blocare, \u0219i piese de blocare a cerin\u021belor structurale ale articolului C2.3.1.<\/p>\n\n\n\n<p>2.GB\/T 3836.2-2021 Apendicele C.2.3 \u00een func\u021bie de caracteristicile sale structurale va fi \u00eemp\u0103r\u021bit \u00een piese de conectare Ex metrice, piese de conectare Ex NPT \u0219i piese de conectare Ex nefiletate cerin\u021be clare, con\u021binutul specific este dup\u0103 cum urmeaz\u0103:<\/p>\n\n\n\n<p>(1) Elementele de blocare Ex metrice trebuie s\u0103 \u00eendeplineasc\u0103 urm\u0103toarele cerin\u021be pentru a aborda introducerea de g\u0103uri \u00een carcas\u0103 prin men\u021binerea suprafe\u021bei exterioare a elementului de blocare c\u00e2t mai aproape de carcas\u0103:<\/p>\n\n\n\n<p>a. Trebuie s\u0103 aib\u0103 flan\u0219e sau cu\u021bite goale pentru a preveni trecerea complet\u0103 a elementului de blocare Ex prin carcas\u0103 \u0219i, \u00een cazul \u00een care sunt prezente flan\u0219e, acestea trebuie s\u0103 aib\u0103 un diametru \u0219i o grosime care s\u0103 \u00eempiedice \u00eendep\u0103rtarea prin alte mijloace dec\u00e2t cele permise mai sus;<\/p>\n\n\n\n<p>b. Fileturile trebuie s\u0103 fie conforme cu cerin\u021bele corespunz\u0103toare de la \u00cembin\u0103rile antideflagrante (C.2.2).<\/p>\n\n\n\n<p>(2) Elementele de blocare NPT Ex trebuie s\u0103 \u00eendeplineasc\u0103 urm\u0103toarele cerin\u021be:<\/p>\n\n\n\n<p>a. Trebuie s\u0103 fie f\u0103r\u0103 flan\u0219e;<\/p>\n\n\n\n<p>b. Tipurile de filet trebuie s\u0103 fie conforme cu ANSI\/ASME B1.20.1 American Standard Tapered Pipe Threads (NPT);<\/p>\n\n\n\n<p>c. Trebuie s\u0103 existe caneluri pentru unelte (ca \u00een figura C.2);<\/p>\n\n\n\n<p>d. Lungimea efectiv\u0103 a filetului nu trebuie s\u0103 fie mai mic\u0103 dec\u00e2t dimensiunea \u201cL2\u201d.<\/p>\n\n\n\n<p>(3) Dopuri Ex nefiletate (numai tip I)<\/p>\n\n\n\n<p>Numai pentru echipamentele din clasa I, piesele de blocare a g\u0103urilor u\u0219oare (g\u0103uri nefiletate) trebuie s\u0103 \u00eendeplineasc\u0103 cerin\u021bele de la C.2.2.2 \u0219i C.2.3.1 din GB\/T3836.2-2021.<\/p>\n\n\n\n<p>Ar trebui acordat\u0103 o aten\u021bie special\u0103:<\/p>\n\n\n\n<p>(1) Dopurile nu trebuie utilizate cu fitinguri filetate.<\/p>\n\n\n\n<p>(2) Dopurile filetate NPT nu trebuie s\u0103 fie proiectate cu o construc\u021bie cu flan\u0219\u0103.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Echipamentul electric antideflagrant utilizat \u00een mod obi\u0219nuit nu este utilizat \u00een introducerea metodelor de conectare<\/strong><strong><\/strong><\/h2>\n\n\n\n<p>Echipamentul electric ignifug nu este utilizat \u00een introducerea gurii, \u00een func\u021bie de introducerea structurii intr\u0103rii pentru a determina metoda de blocare, urm\u0103toarele sunt utilizate \u00een mod obi\u0219nuit pentru echipamentul electric ignifug nu este utilizat \u00een introducerea gurii metodei de blocare, analiza\u021bi \u0219i explica\u021bi pe scurt.<\/p>\n\n\n\n<p>Standard na\u021bional GB\/T 3836.1-2021 Articolul 16.4 \u201c<strong>piese de blocare<\/strong>\u201d este stipulat dup\u0103 cum urmeaz\u0103: utilizat pentru a bloca g\u0103urile redundante din peretele carcasei pieselor de blocare a echipamentelor electrice, ar trebui s\u0103 fie \u00een conformitate cu cerin\u021bele tipului special antiexploziv corespunz\u0103tor.<\/p>\n\n\n\n<p>De obicei, structura portului de introducere a echipamentului electric rezistent la explozii este \u00eemp\u0103r\u021bit\u0103 \u00een dou\u0103 cazuri:<\/p>\n\n\n\n<p>1. Exist\u0103 un dispozitiv de introducere a cablului de tip inel de etan\u0219are pe carcasa antiexploziv\u0103, care adopt\u0103 inelul de etan\u0219are pentru a fixa teaca cablului;<\/p>\n\n\n\n<p>2. Orificiul de introducere de pe carcasa antideflagrant\u0103 este un orificiu de trecere filetat antideflagrant, care trebuie sigilat cu un dop antideflagrant adecvat.<\/p>\n\n\n\n<p>\u00cen primul r\u00e2nd, practica din primul caz, \u201c<strong>Dispozitiv de introducere a cablului cu inel de etan\u0219are pe carcasa antideflagrant\u0103<\/strong>\u201c, este prezentat \u00een figura 1 de mai jos:<\/p>\n\n\n\n<div class=\"wp-block-uagb-image uagb-block-1f7b8e2f wp-block-uagb-image--layout-default wp-block-uagb-image--effect-static wp-block-uagb-image--align-none\"><figure class=\"wp-block-uagb-image__figure\"><a class=\"\" href=\"https:\/\/led.amasly.com\/ro\/\" target=\"\" rel=\"noopener\"><img decoding=\"async\" srcset=\"https:\/\/led.amasly.com\/wp-content\/uploads\/2025\/03\/lQLPJw1WF2PXbMfNAjPNA8ewqdcqnOkEQMcHpHrTAct3AA_967_563.png ,https:\/\/led.amasly.com\/wp-content\/uploads\/2025\/03\/lQLPJw1WF2PXbMfNAjPNA8ewqdcqnOkEQMcHpHrTAct3AA_967_563.png 780w, https:\/\/led.amasly.com\/wp-content\/uploads\/2025\/03\/lQLPJw1WF2PXbMfNAjPNA8ewqdcqnOkEQMcHpHrTAct3AA_967_563.png 360w\" sizes=\"auto, (max-width: 480px) 150px\" src=\"https:\/\/led.amasly.com\/wp-content\/uploads\/2025\/03\/lQLPJw1WF2PXbMfNAjPNA8ewqdcqnOkEQMcHpHrTAct3AA_967_563.png\" alt=\"\" class=\"uag-image-2117\" width=\"967\" height=\"563\" title=\"lQLPJw1WF2PXbMfNAjPNA8ewqdcqnOkEQMcHpHrTAct3AA_967_563\" loading=\"lazy\" role=\"img\"><\/a><\/figure><\/div>\n\n\n\n<p>Structura acestui tip de orificiu de introducere este de a produce deformarea inelului de etan\u0219are prin str\u00e2ngerea inelului de etan\u0219are prin elementul de compresie din fa\u021ba echipamentului, astfel \u00eenc\u00e2t inelul de etan\u0219are s\u0103 prind\u0103 \u00een mod fiabil teaca cablului pentru a realiza performan\u021ba antiexploziv\u0103 \u0219i nu exist\u0103 nicio structur\u0103 a suprafe\u021bei antiexplozibile. \u00cen acest caz, se realizeaz\u0103 metoda de blocare, orificiul s\u0103u de introducere a cablului \u00een exces pe partea exterioar\u0103 a inelului de etan\u0219are trebuie prev\u0103zut cu un dop de o\u021bel\/plac\u0103 de obturare, grosimea pl\u0103cii de obturare <strong>nu trebuie s\u0103 fie mai mic\u0103 de 2 mm<\/strong>, placa de obturare din o\u021bel trebuie presat\u0103 de elementul de compresie, a\u0219a cum se arat\u0103 \u00een figura 1.<\/p>\n\n\n\n<p>\u00cen al doilea caz, \u201c<strong>gaur\u0103 de trecere \u00een carcasa antideflagrant\u0103<\/strong>\u201d este prezentat \u00een figura 2 de mai jos:<\/p>\n\n\n\n<p>\u00cen acest caz, orificiul de introducere de pe carcasa antiexploziv\u0103 este un orificiu de trecere pentru filete antiexplozibile, care trebuie blocat cu un dop antiexplozibil adecvat. Trebuie remarcat faptul c\u0103, \u00een primul r\u00e2nd pentru a determina tipul de filet, cum ar fi, este filet NPT sau filet M, sau alt tip de filet admisibil, \u0219i apoi \u00een func\u021bie de selectarea tipului de filet de obturare antideflagrant adecvat, aceast\u0103 metod\u0103 de obturare este prin interfa\u021ba filetat\u0103 pentru a ob\u021bine performan\u021ba de antideflagrant, trebuie s\u0103 \u00eendeplineasc\u0103 \u0219i urm\u0103toarele condi\u021bii:<\/p>\n\n\n\n<div class=\"wp-block-uagb-image uagb-block-69afa0c9 wp-block-uagb-image--layout-default wp-block-uagb-image--effect-static wp-block-uagb-image--align-none\"><figure class=\"wp-block-uagb-image__figure\"><img decoding=\"async\" srcset=\"https:\/\/led.amasly.com\/wp-content\/uploads\/2025\/03\/lQLPJxVDLHEhDkfNAjTNA-uw4wpXoUW1Zx8HpHrYmd23AA_1003_564.png ,https:\/\/led.amasly.com\/wp-content\/uploads\/2025\/03\/lQLPJxVDLHEhDkfNAjTNA-uw4wpXoUW1Zx8HpHrYmd23AA_1003_564.png 780w, https:\/\/led.amasly.com\/wp-content\/uploads\/2025\/03\/lQLPJxVDLHEhDkfNAjTNA-uw4wpXoUW1Zx8HpHrYmd23AA_1003_564.png 360w\" sizes=\"auto, (max-width: 480px) 150px\" src=\"https:\/\/led.amasly.com\/wp-content\/uploads\/2025\/03\/lQLPJxVDLHEhDkfNAjTNA-uw4wpXoUW1Zx8HpHrYmd23AA_1003_564.png\" alt=\"\" class=\"uag-image-2118\" width=\"1003\" height=\"564\" title=\"lQLPJxVDLHEhDkfNAjTNA-uw4wpXoUW1Zx8HpHrYmd23AA_1003_564\" loading=\"lazy\" role=\"img\"><\/figure><\/div>\n\n\n\n<p>Pas \u2265 0,7 mm, \u00een general nu mai mult de 2 mm;<\/p>\n\n\n\n<p>Fire angajate \u2265 5 catarame;<\/p>\n\n\n\n<p>Ad\u00e2ncimea de angajare: \u22655mm c\u00e2nd volumul dispozitivului este \u2264100cm3 sau \u22658mm c\u00e2nd volumul dispozitivului este &gt;100cm3;<\/p>\n\n\n\n<p>Precizia angaj\u0103rii: Nivel de toleran\u021b\u0103 intermediar sau de precizie \u00een conformitate cu GB\/T 197 \u0219i GB\/T 2516, se recomand\u0103 6H\/6g.<\/p>","protected":false},"excerpt":{"rendered":"<p>Explosion-proof plugging parts related knowledge In the fire and explosion hazardous areas of chemical enterprises, the use of explosion-proof electrical equipment is a common practice in order to effectively control the sparks generated by electrical equipment, to avoid the surrounding leakage of combustible gases into the electrical equipment inside the flash explosion accident. General requirements [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_uag_custom_page_level_css":"","site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[8],"tags":[],"class_list":["post-2114","post","type-post","status-publish","format-standard","hentry","category-explosion-proof-equipment"],"uagb_featured_image_src":{"full":false,"thumbnail":false,"medium":false,"medium_large":false,"large":false,"1536x1536":false,"2048x2048":false,"trp-custom-language-flag":false},"uagb_author_info":{"display_name":"Joe","author_link":"https:\/\/led.amasly.com\/ro\/author\/jacklin\/"},"uagb_comment_info":0,"uagb_excerpt":"Explosion-proof plugging parts related knowledge In the fire and explosion hazardous areas of chemical enterprises, the use of explosion-proof electrical equipment is a common practice in order to effectively control the sparks generated by electrical equipment, to avoid the surrounding leakage of combustible gases into the electrical equipment inside the flash explosion accident. General requirements&hellip;","_links":{"self":[{"href":"https:\/\/led.amasly.com\/ro\/wp-json\/wp\/v2\/posts\/2114","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/led.amasly.com\/ro\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/led.amasly.com\/ro\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/led.amasly.com\/ro\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/led.amasly.com\/ro\/wp-json\/wp\/v2\/comments?post=2114"}],"version-history":[{"count":2,"href":"https:\/\/led.amasly.com\/ro\/wp-json\/wp\/v2\/posts\/2114\/revisions"}],"predecessor-version":[{"id":2335,"href":"https:\/\/led.amasly.com\/ro\/wp-json\/wp\/v2\/posts\/2114\/revisions\/2335"}],"wp:attachment":[{"href":"https:\/\/led.amasly.com\/ro\/wp-json\/wp\/v2\/media?parent=2114"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/led.amasly.com\/ro\/wp-json\/wp\/v2\/categories?post=2114"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/led.amasly.com\/ro\/wp-json\/wp\/v2\/tags?post=2114"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}