{"id":2072,"date":"2025-02-28T21:32:54","date_gmt":"2025-02-28T13:32:54","guid":{"rendered":"https:\/\/led.amasly.com\/?p=2072"},"modified":"2025-03-07T22:18:42","modified_gmt":"2025-03-07T14:18:42","slug":"structura-de-clasificare-si-instalarea-conductelor-flexibile-rezistente-la-explozii-si-cum-sa-judecati-daca-sa-le-instalati-sau-nu","status":"publish","type":"post","link":"https:\/\/led.amasly.com\/ro\/echipamente-antideflagrante\/structura-de-clasificare-si-instalarea-conductelor-flexibile-rezistente-la-explozii-si-cum-sa-judecati-daca-sa-le-instalati-sau-nu\/","title":{"rendered":"Clasificarea, structura \u0219i instalarea conductelor flexibile rezistente la explozii \u0219i modul de a judeca dac\u0103 s\u0103 le instala\u021bi sau nu"},"content":{"rendered":"<p class=\"wp-block-paragraph\">\u021aeav\u0103 flexibil\u0103 rezistent\u0103 la explozii cu retardare la flac\u0103r\u0103, rezisten\u021b\u0103 la coroziune, rezisten\u021b\u0103 la \u00eemb\u0103tr\u00e2nire \u0219i alte avantaje de performan\u021b\u0103, adesea utilizate \u00een cantit\u0103\u021bi mari \u00een petrochimie \u0219i alte locuri periculoase explozive, poate nu numai s\u0103 previn\u0103 \u00een mod eficient apari\u021bia exploziilor \u0219i a incendiilor, dar \u0219i s\u0103 protejeze siguran\u021ba echipamentelor \u0219i a personalului.<\/p>\n\n\n\n<div class=\"wp-block-uagb-image uagb-block-eb50b8be wp-block-uagb-image--layout-default wp-block-uagb-image--effect-static wp-block-uagb-image--align-none\"><figure class=\"wp-block-uagb-image__figure\"><a class=\"\" href=\"https:\/\/led.amasly.com\/ro\/produse\/\" target=\"\" rel=\"noopener\"><img decoding=\"async\" srcset=\"https:\/\/led.amasly.com\/wp-content\/uploads\/2025\/02\/lQLPKGhUcDXAi2fNAfTNArKwdbgidwqWUowHpDeMdZyGAA_690_500.png ,https:\/\/led.amasly.com\/wp-content\/uploads\/2025\/02\/lQLPKGhUcDXAi2fNAfTNArKwdbgidwqWUowHpDeMdZyGAA_690_500.png 780w, https:\/\/led.amasly.com\/wp-content\/uploads\/2025\/02\/lQLPKGhUcDXAi2fNAfTNArKwdbgidwqWUowHpDeMdZyGAA_690_500.png 360w\" sizes=\"auto, (max-width: 480px) 150px\" src=\"https:\/\/led.amasly.com\/wp-content\/uploads\/2025\/02\/lQLPKGhUcDXAi2fNAfTNArKwdbgidwqWUowHpDeMdZyGAA_690_500.png\" alt=\"\" class=\"uag-image-2073\" width=\"690\" height=\"500\" title=\"lQLPKGhUcDXAi2fNAfTNArKwdbgidwqWUowHpDeMdZyGAA_690_500\" loading=\"lazy\" role=\"img\"><\/a><\/figure><\/div>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>I. Clasificarea tubului flexibil antideflagrant<\/strong><strong><\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">1. \u00cen func\u021bie de tipul antiexploziv, conducta flexibil\u0103 antiexploziv\u0103 este, de obicei, \u00eemp\u0103r\u021bit\u0103 \u00een tip antiexploziv \u0219i tip de \u00eembun\u0103t\u0103\u021bire a siguran\u021bei, respectiv, cu echipament antiexploziv \u0219i echipament de \u00eembun\u0103t\u0103\u021bire a siguran\u021bei, ca o conexiune flexibil\u0103 pentru cablarea conductelor. Instalarea pe teren trebuie s\u0103 se potriveasc\u0103 cu echipamentul electric antiexploziv de tip antiexploziv.<br>&nbsp;2. \u00cen func\u021bie de materialul, performan\u021ba \u0219i utilizarea scenei pot fi \u00eemp\u0103r\u021bite \u00een urm\u0103toarele dou\u0103 categorii:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u2460 O\u021bel inoxidabil, rezisten\u021b\u0103 la coroziune \u0219i rezisten\u021b\u0103 la \u00eemb\u0103tr\u00e2nire, instalat \u00een principal \u00een aer liber<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u2461Material din cauciuc, rezisten\u021b\u0103 puternic\u0103 la coroziune rezisten\u021b\u0103 la \u00eemb\u0103tr\u00e2nire \u00een general, instalat \u00een principal \u00een interior<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>II. cerin\u021be privind structura \u021bevii flexibile rezistente la explozii<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">1. \u021aeava flexibil\u0103 antiexploziv\u0103 este format\u0103 din \u00eembin\u0103ri de \u021bevi \u0219i \u021bevi de leg\u0103tur\u0103 la ambele capete, iar \u021bevile de leg\u0103tur\u0103 sunt compuse din \u021bevi interioare \u0219i teci;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">2. Filetul de conectare extern\u0103 al \u00eembin\u0103rii \u021bevii flexibile antideflagrante poate fi realizat \u00een filet metric, filet de \u021beav\u0103 cilindric sau structur\u0103 de filet de \u021beav\u0103 conic\u0103;<br>3. \u00cembin\u0103rile \u021bevilor flexibile antideflagrante trebuie s\u0103 fie realizate din materiale metalice laminate care nu sunt susceptibile la coroziune sau tratament de placare \u0219i nu trebuie s\u0103 fie realizate din materiale metalice u\u0219oare, cu o precizie a filetului de cel pu\u021bin 6g\/6H, un pas de cel pu\u021bin 0,75 mm \u0219i nu mai mult de 3 mm; num\u0103rul de butoane de angajare nu este mai mic de 5 butoane, iar lungimea angaj\u0103rii nu este mai mic\u0103 de 8 mm;<br>4. \u021aeava interioar\u0103 a \u021bevii flexibile antideflagrante trebuie s\u0103 fie fabricat\u0103 din \u021beav\u0103 metalic\u0103 ondulat\u0103, furtun metalic sau \u021beav\u0103 metalic\u0103 cu piele de \u0219arpe, iar \u021beava interioar\u0103 trebuie s\u0103 fie fabricat\u0103 din o\u021bel inoxidabil sau material metalic galvanizat;<br>5. \u00eenveli\u0219ul \u021bevii flexibile antideflagrante poate fi realizat din \u00eenveli\u0219 \u00eempletit din plas\u0103 metalic\u0103, \u00eenveli\u0219 din cauciuc, \u00eenveli\u0219 din plastic \u0219i alte structuri, grosimea \u00eenveli\u0219ului din plastic sau cauciuc nu poate fi mai mic\u0103 de 0,8 mm;<br>6. \u021aeava flexibil\u0103 antideflagrant\u0103 temperatura ambiant\u0103 aplicabil\u0103 ar trebui s\u0103 fie \u00een conformitate cu dispozi\u021biile din tabelul urm\u0103tor:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">&nbsp;&nbsp;&nbsp;Tubul flexibil cu teac\u0103 \u00eempletit\u0103 cu plas\u0103 metalic\u0103 aplicabil la temperatura ambiant\u0103 nu limiteaz\u0103<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">&nbsp;&nbsp;&nbsp;Furtunul flexibil cu \u00eenveli\u0219 de cauciuc aplicabil la temperatura ambiant\u0103 este \u00een general de -20 ~ +60 \u00b0 C<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">&nbsp;&nbsp;&nbsp;Tubul de turnare a tecii din plastic aplicabil la temperatura ambiant\u0103 este \u00een general de +5 ~ +40 \u00b0 C<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Not\u0103: Utilizarea de cauciuc de \u00eenalt\u0103 calitate sau plastic teava \u021beav\u0103 flexibil\u0103, \u00een alt interval de temperatur\u0103 ambiental\u0103, atunci c\u00e2nd testul este calificat, poate fi, de asemenea, adecvat\u0103.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Extinderea intervalului de temperaturi ambientale \u00een care poate fi utilizat.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">7. \u021aevile flexibile rezistente la fl\u0103c\u0103ri pot fi realizate din burdufuri din cupru sau o\u021bel inoxidabil f\u0103r\u0103 sudur\u0103, acoperite cu \u00eempletitur\u0103 de s\u00e2rm\u0103 din cupru, alam\u0103 sau o\u021bel inoxidabil;<br>8. pentru diametrul interior de 20 mm \u0219i mai jos, conducta flexibil\u0103 ignifug\u0103 poate fi utilizat\u0103 \u00een conformitate cu YB \/ T 5306 furtun metalic galvanizat, acoperit cu cauciuc incombustibil sau ignifugat sau manta din plastic;<br>9. \u021aeava flexibil\u0103 care spore\u0219te siguran\u021ba poate fi fabricat\u0103 din furtun metalic galvanizat \u00een conformitate cu YB\/T 5306, acoperit cu \u00eempletitur\u0103 din cupru, alam\u0103 sau o\u021bel inoxidabil sau cu cauciuc neinflamabil sau ignifugat sau cu teac\u0103 din plastic.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>III.Instalarea conductei flexibile antideflagrante<\/strong><\/h2>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>1. Premise de aplicare pentru instalarea conductelor flexibile rezistente la explozii<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u2460 echipamentul antideflagrant este echipat cu introducerea introducerii dispozitivului; \u2461 introducerea dispozitivului con\u021bine o garnitur\u0103; \u2462 dimensiunea inelului de etan\u0219are \u0219i dimensiunea diametrului exterior al cablului (neblindat) pentru a se potrivi cu dimensiunea.<br>\u00a0Pe baza premisei de mai sus, conducta flexibil\u0103 antideflagrant\u0103 \u00een domeniul instal\u0103rii \u0219i aplic\u0103rii trebuie s\u0103 acorde aten\u021bie urm\u0103toarelor dou\u0103 situa\u021bii:<br>\u00a0(1) \u021beav\u0103 flexibil\u0103 antideflagrant\u0103 \u0219i introducerea gurii de tranzi\u021bie \u00eentre instalarea elementelor de compresie<br>\u00a0Aplica\u021bie: Lungimea de compresie neaxial\u0103 a inelului de etan\u0219are este limitat\u0103 \u0219i nu este suficient\u0103 pentru a se asigura c\u0103 tubul flexibil antiexploziv este presat \u00eempotriva inelului de etan\u0219are \u00een dispozitivul de introducere. Planul de instalare: \u00eentre tubul flexibil antiexploziv \u0219i introducerea gurii trebuie s\u0103 fie instalat elementul de compresie de tranzi\u021bie, pentru a atinge scopul primei compresii a inelului de etan\u0219are pentru a \u021bine cablul str\u00e2ns \u0219i apoi pentru a conecta tubul flexibil antiexploziv.<br>\u00a0(2) Conduct\u0103 flexibil\u0103 antiexploziv\u0103 \u0219i introducerea conexiunii directe \u00eentre port<br>\u00a0Aplica\u021bie: compresia neaxial\u0103 a lungimii inelului de etan\u0219are pentru a se asigura c\u0103 compresia tubului flexibil rezistent la explozie introdus \u00een dispozitiv \u00een interiorul inelului de etan\u0219are. Instalare: Conectare direct\u0103 \u00eentre tubul flexibil antiexploziv \u0219i intrare, folosind conectorul frontal al tubului flexibil antiexploziv pentru a comprima inelul de etan\u0219are \u0219i a \u021bine cablul str\u00e2ns.<br><strong>\u00a0<\/strong><\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>2. Instruc\u021biuni speciale:<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Trebuie acordat\u0103 o aten\u021bie deosebit\u0103 faptului c\u0103, dac\u0103 se aplic\u0103 metoda de cablare cu cablu blindat, dispozitivul de introducere a cablului blindat trebuie instalat la orificiul de introducere al echipamentului electric antiexploziv \u00eenainte de conectarea tubului flexibil.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>VI. <\/strong><strong>Scenarii de aplicare a tubului flexibil rezistent la explozii<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Tubulatura flexibil\u0103 antideflagrant\u0103 face parte din cablajul \u021bevilor de o\u021bel Pentru a evita deteriorarea sub tensiune, tubulatura flexibil\u0103 antideflagrant\u0103 trebuie utilizat\u0103 cu cablajul \u021bevilor de o\u021bel \u0219i \u00een urm\u0103toarele trei scenarii.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">1. Intrarea motorului;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">2. \u00cen cazul \u00een care exist\u0103 dificult\u0103\u021bi \u00een conectarea conductei la echipamentul electric;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">3. \u00cen cazul \u00een care conducta trece prin rosturi de dilatare \u0219i rosturi de instalare \u00een cl\u0103diri.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>V. Este necesar\u0103 instalarea \u021bevii flexibile antideflagrante<\/strong><\/h2>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>1. Avantaje \u0219i dezavantaje ale \u021bevilor flexibile antideflagrante<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u021aeava de conectare flexibil\u0103 antiexploziv\u0103 are avantajele de a fi rezistent\u0103 la flac\u0103r\u0103, rezistent\u0103 la coroziune, rezistent\u0103 la ap\u0103, rezistent\u0103 la \u00eemb\u0103tr\u00e2nire, structur\u0103 solid\u0103 etc. \u00cen plus, \u021beava flexibil\u0103 antideflagrant\u0103 poate proteja cablul de deteriorare. Cu toate acestea, din cauza tubului flexibil antiexploziv \u00een jonc\u021biunea instrumentului nu este sigilat\u0103, cel mai mare dezavantaj al s\u0103u este instrumentul \u00een ap\u0103, instrumentul \u00een ap\u0103 este deteriorarea instrumentului u\u0219or, e\u0219ecul de control al instrumentului greu, ceea ce duce la accidente de siguran\u021b\u0103. Acesta este principalul motiv pentru care tubul flexibil antideflagrant nu este binevenit de personalul de \u00eentre\u021binere a instrumentelor. 2.<br><strong>\u00a0<\/strong><\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>2. Din punctul de vedere al specifica\u021biilor, trebuie s\u0103 fie echipat cu un tub flexibil rezistent la explozii<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Men\u021bionarea specifica\u021biei \u021bevii flexibile rezistente la explozie, numai construc\u021bia nou\u0103, modificat\u0103 (extindere) a instrumenta\u021biei de inginerie a conductelor de petrol \u0219i gaze ar trebui s\u0103 fie echipat\u0103 cu \u021beav\u0103 flexibil\u0103 rezistent\u0103 la explozie, iar alte specifica\u021bii de instrumenta\u021bie, nu exist\u0103 cerin\u021be de specifica\u021bie pentru instrumenta\u021bia cu \u021beav\u0103 flexibil\u0103 rezistent\u0103 la explozie, \u021beav\u0103 flexibil\u0103 rezistent\u0103 la explozie \u0219i cablu rezistent la explozie \u0219i articula\u021biile de etan\u0219are \u00eendeplinesc cerin\u021bele.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>3. Alege\u021bi dac\u0103 s\u0103 instala\u021bi sau nu o conduct\u0103 flexibil\u0103 antideflagrant\u0103 \u00een func\u021bie de situa\u021bia specific\u0103.<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u2460 Pentru instrumentele de circuit cu siguran\u021b\u0103 intrinsec\u0103, nu este nevoie s\u0103 v\u0103 g\u00e2ndi\u021bi dac\u0103 s\u0103 le dota\u021bi sau nu cu \u021bevi flexibile antideflagrante. Instrumente cu siguran\u021b\u0103 intrinsec\u0103 datorit\u0103 limit\u0103rilor energetice ale re\u021belei de siguran\u021b\u0103, chiar dac\u0103 circuitul este scurtcircuitat, curentul maxim nu dep\u0103\u0219e\u0219te \u00een general 50mA, energia nu este suficient\u0103 pentru a aprinde gaze inflamabile, adic\u0103 nu are rost s\u0103 discut\u0103m dac\u0103 s\u0103 ad\u0103ug\u0103m sau nu tubul flexibil antiexploziv.<br>\u00a0\u2461 Pentru instrumenta\u021bie antiexploziv\u0103, electrovalve, alarme pentru gaze combustibile \u0219i toxice etc., se poate utiliza \u021beav\u0103 flexibil\u0103 antiexploziv\u0103, se poate utiliza, de asemenea, conector de etan\u0219are prindere cablu antiexploziv. Aceste dou\u0103 configura\u021bii sunt \u00een conformitate cu cerin\u021bele specifica\u021biilor.<br>\u00a0\u2462 Pentru unele alte cerin\u021be speciale, cum ar fi \u201csubstan\u021be chimice periculoase surse majore de risc specifica\u021biile de configurare a echipamentului de monitorizare a siguran\u021bei locului rezervorului\u201d 4.2.5 a declarat \u00een zona rezervorului constituie o surs\u0103 major\u0103 de risc \u0219i conducte de petrol \u0219i gaze, \u00een conformitate cu normele de punere \u00een aplicare a opera\u021biunii standard.<br>\u00a0\u2463 Din punctul de vedere al siguran\u021bei, utilizarea general\u0103 a cablurilor din \u021bevi de o\u021bel poate preveni mai bine daunele mecanice \u0219i poate \u00eendeplini cerin\u021bele codului \u00een general.<br>\u00a0\u2464 Din punctul de vedere al proprietarului, \u021bevile flexibile rezistente la explozii pot proteja mai eficient cablurile, pot prelungi timpul de \u00eemb\u0103tr\u00e2nire a tecii cablului \u0219i pot face fa\u021b\u0103 inspec\u021biilor.<br>\u00a0\u00a0\u00a0\u00a0\u00a0\u00cen orice caz, proiectarea trebuie s\u0103 fie \u00een primul r\u00e2nd conform\u0103 din punct de vedere juridic \u0219i \u00een al doilea r\u00e2nd rezonabil\u0103. Atunci c\u00e2nd cablurile sunt utilizate pentru cabluri electrice, se poate renun\u021ba la \u021bevile flexibile \u00een fabrici \u0219i instala\u021bii, dar pentru unele medii dure, cum ar fi pentru prevenirea r\u0103nilor mecanice \u0219i \u00eemb\u0103tr\u00e2nirea u\u0219oar\u0103 a tecii cablului, este mai rezonabil s\u0103 se utilizeze \u021bevi flexibile.<\/p>","protected":false},"excerpt":{"rendered":"<p>Explosion-proof flexible pipe with flame retardant, corrosion resistance, aging resistance and other performance advantages, often used in large quantities in petrochemical and other explosive hazardous places, it can not only effectively prevent the occurrence of explosions and fires, but also protect the safety of equipment and personnel. I. Classification of explosion-proof flexible tube 1. According [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_uag_custom_page_level_css":"","site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[8],"tags":[],"class_list":["post-2072","post","type-post","status-publish","format-standard","hentry","category-explosion-proof-equipment"],"uagb_featured_image_src":{"full":false,"thumbnail":false,"medium":false,"medium_large":false,"large":false,"1536x1536":false,"2048x2048":false,"trp-custom-language-flag":false},"uagb_author_info":{"display_name":"Joe","author_link":"https:\/\/led.amasly.com\/ro\/author\/jacklin\/"},"uagb_comment_info":0,"uagb_excerpt":"Explosion-proof flexible pipe with flame retardant, corrosion resistance, aging resistance and other performance advantages, often used in large quantities in petrochemical and other explosive hazardous places, it can not only effectively prevent the occurrence of explosions and fires, but also protect the safety of equipment and personnel. I. Classification of explosion-proof flexible tube 1. According&hellip;","_links":{"self":[{"href":"https:\/\/led.amasly.com\/ro\/wp-json\/wp\/v2\/posts\/2072","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/led.amasly.com\/ro\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/led.amasly.com\/ro\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/led.amasly.com\/ro\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/led.amasly.com\/ro\/wp-json\/wp\/v2\/comments?post=2072"}],"version-history":[{"count":2,"href":"https:\/\/led.amasly.com\/ro\/wp-json\/wp\/v2\/posts\/2072\/revisions"}],"predecessor-version":[{"id":2347,"href":"https:\/\/led.amasly.com\/ro\/wp-json\/wp\/v2\/posts\/2072\/revisions\/2347"}],"wp:attachment":[{"href":"https:\/\/led.amasly.com\/ro\/wp-json\/wp\/v2\/media?parent=2072"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/led.amasly.com\/ro\/wp-json\/wp\/v2\/categories?post=2072"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/led.amasly.com\/ro\/wp-json\/wp\/v2\/tags?post=2072"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}