{"id":3014,"date":"2025-04-09T21:16:22","date_gmt":"2025-04-09T13:16:22","guid":{"rendered":"https:\/\/led.amasly.com\/?page_id=3014"},"modified":"2025-04-09T21:16:29","modified_gmt":"2025-04-09T13:16:29","slug":"what-is-the-principle-of-explosion-proof","status":"publish","type":"page","link":"https:\/\/led.amasly.com\/ro\/knowledge\/explosion-proof-products-knowledge\/what-is-the-principle-of-explosion-proof\/","title":{"rendered":"Care este principiul rezisten\u021bei la explozie?"},"content":{"rendered":"<div class=\"wp-block-uagb-container uagb-block-27bae773 alignfull uagb-is-root-container\"><div class=\"uagb-container-inner-blocks-wrap\"><\/div><\/div>\n\n\n\n<h2 class=\"wp-block-heading has-text-align-center\"><strong>Care este principiul rezisten\u021bei la explozie?<\/strong><strong><\/strong><\/h2>\n\n\n\n<div class=\"wp-block-uagb-image uagb-block-da1360b5 wp-block-uagb-image--layout-default wp-block-uagb-image--effect-static wp-block-uagb-image--align-none\"><figure class=\"wp-block-uagb-image__figure\"><a class=\"\" href=\"https:\/\/led.amasly.com\/ro\/\" target=\"\" rel=\"noopener\"><img decoding=\"async\" srcset=\"https:\/\/led.amasly.com\/wp-content\/uploads\/2025\/01\/LED-explosion-proof-flood-lights.png ,https:\/\/led.amasly.com\/wp-content\/uploads\/2025\/01\/LED-explosion-proof-flood-lights.png 780w, https:\/\/led.amasly.com\/wp-content\/uploads\/2025\/01\/LED-explosion-proof-flood-lights.png 360w\" sizes=\"auto, (max-width: 480px) 150px\" src=\"https:\/\/led.amasly.com\/wp-content\/uploads\/2025\/01\/LED-explosion-proof-flood-lights.png\" alt=\"\" class=\"uag-image-1675\" width=\"1004\" height=\"308\" title=\"Lumini de inunda\u021bie cu LED-uri antiexplozie\" loading=\"lazy\" role=\"img\"><\/a><\/figure><\/div>\n\n\n\n<p class=\"wp-block-paragraph\">Protec\u021bia \u00eempotriva exploziilor (protec\u021bia \u00eempotriva exploziilor) se refer\u0103 la capacitatea de a rezista la impactul exploziei \u0219i c\u0103ldurii f\u0103r\u0103 pierderea func\u021bion\u0103rii normale se nume\u0219te protec\u021bie \u00eempotriva exploziilor, pentru a preveni generarea de explozii trebuie s\u0103 fie luate \u00een considerare din cele trei condi\u021bii necesare, limit\u00e2nd una dintre condi\u021biile necesare pentru a limita generarea de explozii.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>T<\/strong><strong>Trei condi\u021bii necesare<\/strong><strong><\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">1, cele trei condi\u021bii necesare pentru a provoca o explozie, trei condi\u021bii \u00een acela\u0219i timp - explozie<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">aprinde aprinde; gaze de ardere comburant (substan\u021be speciale pot fi non-O condi\u021bii de ardere \u0219i explozie, cum ar fi Mg \u00een dioxid de carbon poate arde violent); combustibil combustibil.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">2, pentru a preveni apari\u021bia exploziilor trebuie luate \u00een considerare cele trei condi\u021bii necesare, pentru a limita una dintre condi\u021biile necesare, pentru a limita apari\u021bia exploziilor.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">prevenirea exploziilor de substan\u021be explozive \u0219i inflamabile \u00een uzinele chimice, rafin\u0103rii.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Echipamentele \u0219i conductele din cauza etan\u0219\u0103rii necorespunz\u0103toare cauzate de sc\u0103parea substan\u021belor explozive sau inflamabile, \u00eent\u00e2lnite \u00een instrumenta\u021bia contactelor electrice \u0219i a sc\u00e2nteilor de scurtcircuit ale echipamentelor electrice formate, pot provoca o explozie sau o combustie.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Rezistent la explozie<\/strong><strong>&nbsp;m\u0103suri<\/strong><strong><\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">(1) Selecta\u021bi instrumenta\u021bia \u0219i echipamentele electrice antiexplozive adecvate, structura standard: Protec\u021bia \u00eempotriva exploziilor, siguran\u021b\u0103 sporit\u0103, presiune pozitiv\u0103, umplut cu nisip, siguran\u021b\u0103 intrinsec\u0103 \u0219i umplut cu ulei.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">(2) Selectarea metodelor de ventila\u021bie adaptate.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">(3) Prevenirea sau reducerea la minimum a posibilit\u0103\u021bii de scurgere a substan\u021belor inflamabile.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">(4) Nu utiliza\u021bi sau reduce\u021bi la minimum utilizarea componentelor electrice care sunt predispuse la sc\u00e2ntei.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">(5) Men\u021bine\u021bi o stare inert\u0103 prin umplerea cu azot gazos.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Rezistent la explozie<\/strong><strong>&nbsp;design<\/strong><strong><\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u00cen proiectarea cl\u0103dirii, ar trebui s\u0103 fie rezonabil pentru a determina cerin\u021bele cl\u0103dirii:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">(1) num\u0103rul de etaje ale cl\u0103dirii. \u00cen general, este adecvat s\u0103 se utilizeze o cl\u0103dire cu un singur etaj. Pentru trebuie s\u0103 ia fluxul procesului de produc\u021bie de jos \u00een sus sau de sus \u00een jos al cl\u0103dirii poate fi utilizat\u0103 numai cl\u0103direa cu mai multe etaje.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u00cen cl\u0103direa cu mai multe etaje, \u00een cazul \u00een care numai o parte a camerei antiexplozie, aceasta ar trebui s\u0103 fie amenajat\u0103, pe c\u00e2t posibil, la etajul superior, nu poate fi amenajat\u0103 la subsol sau semisubsol.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u00cen cazul \u00een care procesul de protec\u021bie \u00eempotriva exploziilor este \u00een sus \u0219i \u00een jos p\u00e2n\u0103 \u00een partea de sus a ultimului etaj, ar trebui s\u0103 fie deschise g\u0103uri de u\u0219urare la fiecare etaj, suprafa\u021ba nu ar trebui s\u0103 fie mai mic\u0103 de 15% din suprafa\u021ba podelei, acoperi\u0219ul acoperi\u0219ului u\u0219or de u\u0219urare a presiunii.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u2461 nivelul de rezisten\u021b\u0103 la foc. Exploziile conduc adesea la incendii, cl\u0103dirile rezistente la explozii ar trebui s\u0103 aib\u0103 un grad ridicat de rezisten\u021b\u0103 la foc: cl\u0103direa cu un singur etaj nu mai pu\u021bin de dou\u0103, cl\u0103direa cu mai multe etaje ar trebui s\u0103 fie un nivel.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u2462 tipul de structur\u0103. Pentru a evita explozia cauzat\u0103 de pr\u0103bu\u0219irea cl\u0103dirii, cl\u0103direa trebuie s\u0103 fie selectat\u0103 ca structur\u0103 portant\u0103 rezistent\u0103 la explozii \u0219i s\u0103 se ia m\u0103suri de reducere a presiunii. \u00cen general, structura din beton armat; \u00een cazul \u00een care peretele este mai gros sau suprafa\u021ba cl\u0103dirii rezistente la explozii este foarte mic\u0103, se poate utiliza structura mixt\u0103 portant\u0103 cu pere\u021bi din c\u0103r\u0103mid\u0103, dar trebuie s\u0103 se stabileasc\u0103 un acoperi\u0219 u\u0219or de desc\u0103rcare a presiunii.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u2463 forma planului. Planul cl\u0103dirii trebuie s\u0103 fie dreptunghiular. Cu c\u00e2t l\u0103\u021bimea cl\u0103dirii este mai mic\u0103, cu at\u00e2t raportul dintre suprafa\u021ba pere\u021bilor exteriori \u0219i volum este mai mare, cu at\u00e2t este mai favorabil luminii, ventila\u021biei \u0219i eliber\u0103rii presiunii. L\u0103\u021bimea cl\u0103dirii cu mai multe etaje nu trebuie s\u0103 fie mai mare de 18 metri.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u2464 Intr\u0103ri \u0219i ie\u0219iri de siguran\u021b\u0103. Intr\u0103rile \u0219i ie\u0219irile pentru evacuarea de siguran\u021b\u0103, \u00een general, nu trebuie s\u0103 fie mai mici de dou\u0103 \u0219i trebuie s\u0103 respecte distan\u021ba de evacuare de siguran\u021b\u0103 \u0219i l\u0103\u021bimea de evacuare \u0219i alte cerin\u021be.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u2465 Dispunerea sec\u021biunii antiexplozive. Cl\u0103dirile trebuie s\u0103 fie doar par\u021bial rezistente la explozii, sec\u021biunea rezistent\u0103 la explozii ar trebui s\u0103 fie dispus\u0103 l\u00e2ng\u0103 peretele exterior, necesit\u00e2nd cel pu\u021bin dou\u0103 suprafe\u021be de perete exterior;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u00cen cazul \u00een care exist\u0103 o singur\u0103 suprafa\u021b\u0103 de perete exterior, suprafa\u021ba acestuia ar trebui s\u0103 reprezinte mai mult de 25% din perimetrul total al \u00eenc\u0103perii. produc\u021bie de explozivi \u00een instala\u021bie, este oportun s\u0103 se utilizeze o cl\u0103dire deschis\u0103 sau semi-deschis\u0103.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Rezistent la explozie<\/strong><strong>&nbsp;echipamente<\/strong><strong><\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Defini\u021bie: echipament electric care nu va provoca aprinderea mediului exploziv \u00eenconjur\u0103tor \u00een condi\u021biile specificate.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\"><strong>\u00cemp\u0103r\u021bite \u00een trei categorii:<\/strong><strong><\/strong><\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">Clasa \u2160: echipamente electrice subterane pentru mine de c\u0103rbune;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Clasa \u2161: \u00een plus fa\u021b\u0103 de minele de c\u0103rbune, subterane, toate celelalte echipamente electrice pentru atmosfere explozive.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Clasa \u2161 poate fi \u00eemp\u0103r\u021bit\u0103 \u00een clasele \u2161 A, \u2161 B, \u2161 C, marcajul echipamentului \u2161 B poate fi aplicat condi\u021biilor de utilizare a echipamentului \u2161 A; \u2161 C poate fi aplicat condi\u021biilor de utilizare \u2161 A, \u2161 B.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Clasa III: echipamente electrice utilizate \u00een medii cu praf exploziv, altele dec\u00e2t minele de c\u0103rbune<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Clasa III echipamente electrice electrice \u00een \u00eemp\u0103r\u021bite \u00een: Clasa IIIA: de\u0219euri combustibile; Clasa IIIB: praf neconductiv; Clasa IIIC: praf conductiv.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Not\u0103: marcajul \u2161 C reprezint\u0103 un nivel superior de protec\u021bie \u00eempotriva exploziilor, dar nu \u00eenseamn\u0103 c\u0103 echipamentul are cele mai bune performan\u021be.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Temperatura maxim\u0103 a suprafe\u021bei: echipamentul electric \u00een intervalul specificat al celor mai nefavorabile condi\u021bii de func\u021bionare, poate cauza aprinderea mediului exploziv din jur a oric\u0103rei p\u0103r\u021bi a echipamentului electric pentru a atinge cea mai ridicat\u0103 temperatur\u0103. Temperatura maxim\u0103 a suprafe\u021bei trebuie s\u0103 fie mai mic\u0103 dec\u00e2t temperatura combustibilului.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">De exemplu: Mediul senzorului rezistent la explozie al temperaturii de aprindere a gazului exploziv de 100 \u2103, apoi senzorul \u00een cele mai nefavorabile condi\u021bii de func\u021bionare, temperatura maxim\u0103 a suprafe\u021bei oric\u0103reia dintre componentele sale trebuie s\u0103 fie mai mic\u0103 de 100 \u2103.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Grupa de temperatur\u0103: echipamentul electric pentru atmosfere explozive \u00een func\u021bie de temperatura maxim\u0103 a suprafe\u021bei este \u00eemp\u0103r\u021bit \u00een grupe T1-T6<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td>T1<\/td><td>T2<\/td><td>T3<\/td><td>T4<\/td><td>T5<\/td><td>T6<\/td><\/tr><tr><td>450 \u2103<\/td><td>300 \u2103<\/td><td>200\u2103<\/td><td>135 \u2103<\/td><td>100 \u2103<\/td><td>85\u2103<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Rezistent la explozie<\/strong><strong>&nbsp;cale<\/strong><strong><\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Mediile periculoase explozive din fabrici sau din zonele miniere, \u00een func\u021bie de energia de aprindere, temperatura minim\u0103 de aprindere \u0219i prezen\u021ba gazelor periculoase explozive la fa\u021ba locului, perioada de timp pentru clasificarea \u0219i clasificarea \u0219tiin\u021bific\u0103, pentru a determina echipamentul antiexploziv la fa\u021ba locului Semne antiexplozive \u0219i forma antiexploziv\u0103.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\"><strong>Explicarea termenilor:<\/strong><strong><\/strong><\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">clasa ia: \u00een func\u021bionare normal\u0103, o defec\u021biune \u0219i dou\u0103 defec\u021biuni nu pot aprinde amestecul de gaze explozive al echipamentului electric.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Pentru func\u021bionarea normal\u0103, factorul de siguran\u021b\u0103 este 2,0; pentru o defec\u021biune, factorul de siguran\u021b\u0103 este 1,5; pentru dou\u0103 defec\u021biuni, factorul de siguran\u021b\u0103 este 1,0.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Not\u0103: contactele cu sc\u00e2ntei trebuie ad\u0103ugate cu carcas\u0103 antiexploziv\u0103, carcas\u0103 etan\u0219\u0103 la gaze sau dublate pentru a cre\u0219te factorul de siguran\u021b\u0103.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Clasa ib: Echipamente electrice care nu pot aprinde amestecuri de gaze explozive \u00een timpul func\u021bion\u0103rii normale \u0219i al unei defec\u021biuni.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u00cen func\u021bionare normal\u0103, factorul de siguran\u021b\u0103 este de 2,0; \u00een caz de defec\u021biune, factorul de siguran\u021b\u0103 este de 1,5.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u00cen timpul func\u021bion\u0103rii normale, contactele de sc\u00e2nteie trebuie s\u0103 fie protejate de o carcas\u0103 antiexploziv\u0103 sau etan\u0219\u0103 la gaze \u0219i exist\u0103 m\u0103suri pentru afi\u0219area automat\u0103 a defec\u021biunilor, iar coeficientul de siguran\u021b\u0103 este de 1,0 pentru o singur\u0103 defec\u021biune.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">EExd: \u00eenseamn\u0103 semnifica\u021bia pachetului de explozie;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">IIC: se refer\u0103 la energia de aprindere uJ,280,&gt;180,60.... .80,&lt;60; T6: se refer\u0103 la grupul de temperatur\u0103, adic\u0103 echipamentul electric \u00een func\u021bie de temperatura maxim\u0103 a suprafe\u021bei sale este \u00eemp\u0103r\u021bit \u00een diferite grupuri de temperatur\u0103. Grupele de temperatur\u0103 ale gazelor sunt \u00eemp\u0103r\u021bite \u00een func\u021bie de diferite temperaturi de aprindere. t6 este de 85 de grade.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Echipament electric rezistent la explozie (d): se refer\u0103 la componentele care pot aprinde amestecul exploziv este \u00eenchis \u00eentr-o cochilie, cochilia poate rezista la presiunea de explozie a amestecului exploziv intern \u0219i poate preveni \u0219i amestecul exploziv din jur \u0219i amestecul exploziv al echipamentului electric.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Echipamente electrice cu siguran\u021b\u0103 sporit\u0103 (e): \u00een condi\u021bii normale de func\u021bionare, nu produce aprinderea amestecurilor explozive de sc\u00e2ntei sau temperaturi periculoase, iar \u00een structura m\u0103surilor de \u00eembun\u0103t\u0103\u021bire a gradului de siguran\u021b\u0103, pentru a evita fenomenul de aprindere \u00een condi\u021bii normale \u0219i de suprasarcin\u0103 specificate ale echipamentelor electrice.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Echipament electric cu siguran\u021b\u0103 intrinsec\u0103 (i): echipament electric \u00een care nici sc\u00e2nteile, nici efectele termice nu pot aprinde amestecuri explozive \u00een condi\u021bii normale de func\u021bionare sau \u00een condi\u021bii standard de testare.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Echipament electric f\u0103r\u0103 sc\u00e2ntei (n): \u00een condi\u021bii normale de func\u021bionare nu produce arcuri sau sc\u00e2ntei \u0219i nu produce poate aprinde amestecul exploziv din jur de suprafe\u021be la temperaturi ridicate sau puncte de ardere \u0219i, \u00een general, nu apare cu aprinderea defec\u021biunii echipamentului electric.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Tip special antiexplozie (s): echipamente sau componente electrice care utilizeaz\u0103 GB3836-83 neincluse \u00een tipul antiexplozie, autorit\u0103\u021bile competente s\u0103 elaboreze reglement\u0103ri temporare. Trimis la Ministerul Muncii \u0219i Personalului pentru \u00eenregistrare \u0219i prin testul unit\u0103\u021bii de identificare desemnate, \u00een conformitate cu eliminarea echipamentelor electrice speciale de tip \u201cs\u201d.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Zona exploziv\u0103<\/strong><strong><\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Zonele periculoase din sensul regiunii este existen\u021ba real\u0103 a posibilit\u0103\u021bii de m\u0103sur\u0103tori periculoase, care prevede tipul aplicabil de protec\u021bie \u00eempotriva exploziilor.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">1, Comisia Electrotehnic\u0103 Interna\u021bional\u0103 \/ Comisia Electrotehnic\u0103 European\u0103 a clasificat clasificarea zonelor periculoase:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Zona 0 (Zona 0): Gaze explozive \u00eentotdeauna sau pentru o perioad\u0103 lung\u0103 de timp; prezen\u021ba continu\u0103 a unei zone periculoase mai mare de 1000 ore \/ an;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Zona 1 (Zona 1): este probabil s\u0103 apar\u0103 sau s\u0103 existe gaze inflamabile \u00een timpul func\u021bion\u0103rii corespunz\u0103toare a instrumentului; prezen\u021ba intermitent\u0103 a gazelor periculoase 10~1000 ore\/an;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Zona 2: \u00cen general, nu exist\u0103 gaz inflamabil \u0219i chiar dac\u0103 apare ocazional, timpul de baz\u0103 de existen\u021b\u0103 este foarte scurt; pericolul de stare accidental\u0103 exist\u0103 \u00een zona de 0,1 ~ 10 ore \/ an;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">China este \u00eemp\u0103r\u021bit\u0103 \u00een zone periculoase \u0219i la fel ca mai sus.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">2, clasificarea zonelor explozive, standarde interna\u021bionale \u0219i standarde americane pentru compara\u021bie<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"http:\/\/www.iecex-certs.com\/\" rel=\"nofollow noopener\" target=\"_blank\">I.E.C.<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Gaz Zona 0, Zona 1, Zona 2<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Praf Zona 20, Zona 21, Zona 22<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"http:\/\/www.ul.com\" rel=\"nofollow noopener\" target=\"_blank\">N.E.C.<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Gaze Clasa I, Diviziunea I, Clasa I, Diviziunea I, Clasa I, Diviziunea II<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Praf Clasa II, Divizia I, Clasa II, Divizia II<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">I.E.C.: Comisia Electrotehnic\u0103 Interna\u021bional\u0103<\/p>\n\n\n\n<p class=\"has-text-align-left wp-block-paragraph\">N.E.C.: Codul electric na\u021bional, S.U.A.<\/p>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-c7d898dd alignfull uagb-is-root-container\"><div class=\"uagb-container-inner-blocks-wrap\"><\/div><\/div>\n\n\n\n<h2 class=\"wp-block-heading\">Produse conexe<\/h2>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-66e4defc alignfull uagb-is-root-container\"><div class=\"uagb-container-inner-blocks-wrap\">\n<div class=\"wp-block-uagb-container uagb-block-a42945f9\">\n<div class=\"wp-block-uagb-image uagb-block-7296296b wp-block-uagb-image--layout-default wp-block-uagb-image--effect-static wp-block-uagb-image--align-none\"><figure class=\"wp-block-uagb-image__figure\"><a class=\"\" href=\"https:\/\/led.amasly.com\/ro\/products\/\" target=\"\" rel=\"noopener\"><img decoding=\"async\" srcset=\"https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/09\/Explosion-proof-high-bay-lights.png ,https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/09\/Explosion-proof-high-bay-lights.png 780w, https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/09\/Explosion-proof-high-bay-lights.png 360w\" sizes=\"auto, (max-width: 480px) 150px\" src=\"https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/09\/Explosion-proof-high-bay-lights.png\" alt=\"\" class=\"uag-image-1495\" width=\"300\" height=\"300\" title=\"Lumini de \u00eenalt\u0103 rezisten\u021b\u0103 la explozie\" loading=\"lazy\" role=\"img\"><\/a><\/figure><\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-4d3efde5\">\n<div class=\"wp-block-uagb-image uagb-block-c9e90797 wp-block-uagb-image--layout-default wp-block-uagb-image--effect-static wp-block-uagb-image--align-none\"><figure class=\"wp-block-uagb-image__figure\"><a class=\"\" href=\"https:\/\/led.amasly.com\/ro\/products\/\" target=\"\" rel=\"noopener\"><img decoding=\"async\" srcset=\"https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/07\/LED-tri-proof-lights2.png ,https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/07\/LED-tri-proof-lights2.png 780w, https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/07\/LED-tri-proof-lights2.png 360w\" sizes=\"auto, (max-width: 480px) 150px\" src=\"https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/07\/LED-tri-proof-lights2.png\" alt=\"\" class=\"uag-image-1132\" width=\"300\" height=\"300\" title=\"LED-tri-proof-lights2\" loading=\"lazy\" role=\"img\"><\/a><\/figure><\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-11c2578b\">\n<div class=\"wp-block-uagb-image uagb-block-6e8883aa wp-block-uagb-image--layout-default wp-block-uagb-image--effect-static wp-block-uagb-image--align-none\"><figure class=\"wp-block-uagb-image__figure\"><a class=\"\" href=\"https:\/\/led.amasly.com\/ro\/products\/\" target=\"\" rel=\"noopener\"><img decoding=\"async\" srcset=\"https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/09\/LED-Explosion-Proof-Gas-Station-Light.png ,https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/09\/LED-Explosion-Proof-Gas-Station-Light.png 780w, https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/09\/LED-Explosion-Proof-Gas-Station-Light.png 360w\" sizes=\"auto, (max-width: 480px) 150px\" src=\"https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/09\/LED-Explosion-Proof-Gas-Station-Light.png\" alt=\"\" class=\"uag-image-1501\" width=\"300\" height=\"300\" title=\"LED lumina sta\u021biei de benzin\u0103 cu dovada exploziei\" loading=\"lazy\" role=\"img\"><\/a><\/figure><\/div>\n<\/div>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-548945b5 alignfull uagb-is-root-container\"><div class=\"uagb-container-inner-blocks-wrap\">\n<div class=\"wp-block-uagb-container uagb-block-967755d5\">\n<h4 class=\"wp-block-heading has-text-align-center\"><a href=\"https:\/\/led.amasly.com\/ro\/products\/\">Lumini LED antiexplozie<\/a><\/h4>\n<\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-9bc52fc2\">\n<h4 class=\"wp-block-heading has-text-align-center\"><a href=\"https:\/\/led.amasly.com\/ro\/products\/\">Lumini LED Tri-Proof<\/a><\/h4>\n<\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-8ffa0a23\">\n<h4 class=\"wp-block-heading has-text-align-center\"><a href=\"https:\/\/led.amasly.com\/ro\/products\/\">Lumini de sta\u021bie de benzin\u0103 antiexplozie<\/a><\/h4>\n<\/div>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-29499fe0 alignfull uagb-is-root-container\"><div class=\"uagb-container-inner-blocks-wrap\">\n<div class=\"wp-block-uagb-container uagb-block-777ee1c7\">\n<div class=\"wp-block-uagb-image uagb-block-2e9a1851 wp-block-uagb-image--layout-default wp-block-uagb-image--effect-static wp-block-uagb-image--align-none\"><figure class=\"wp-block-uagb-image__figure\"><a class=\"\" href=\"https:\/\/led.amasly.com\/ro\/products\/\" target=\"\" rel=\"noopener\"><img decoding=\"async\" srcset=\"https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/10\/50W-100W-150W-200W-300W-LED-Flood-Light.jpg ,https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/10\/50W-100W-150W-200W-300W-LED-Flood-Light.jpg 780w, https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/10\/50W-100W-150W-200W-300W-LED-Flood-Light.jpg 360w\" sizes=\"auto, (max-width: 480px) 150px\" src=\"https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/10\/50W-100W-150W-200W-300W-LED-Flood-Light.jpg\" alt=\"\" class=\"uag-image-1526\" width=\"300\" height=\"300\" title=\"50W 100W 150W 200W 300W LED lumin\u0103 de inunda\u021bie\" loading=\"lazy\" role=\"img\"><\/a><\/figure><\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-af8c8683\">\n<div class=\"wp-block-uagb-image uagb-block-67947854 wp-block-uagb-image--layout-default wp-block-uagb-image--effect-static wp-block-uagb-image--align-none\"><figure class=\"wp-block-uagb-image__figure\"><a class=\"\" href=\"https:\/\/led.amasly.com\/ro\/products\/\" target=\"\" rel=\"noopener\"><img decoding=\"async\" srcset=\"https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/07\/led-tri-proof-light.png ,https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/07\/led-tri-proof-light.png 780w, https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/07\/led-tri-proof-light.png 360w\" sizes=\"auto, (max-width: 480px) 150px\" src=\"https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/07\/led-tri-proof-light.png\" alt=\"\" class=\"uag-image-1130\" width=\"300\" height=\"300\" title=\"led-tri-proof-light\" loading=\"lazy\" role=\"img\"><\/a><\/figure><\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-0fdfdd58\">\n<div class=\"wp-block-uagb-image uagb-block-1187d32d wp-block-uagb-image--layout-default wp-block-uagb-image--effect-static wp-block-uagb-image--align-none\"><figure class=\"wp-block-uagb-image__figure\"><a class=\"\" href=\"https:\/\/led.amasly.com\/ro\/products\/\" target=\"\" rel=\"noopener\"><img decoding=\"async\" srcset=\"https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/07\/LED-street-light.jpg ,https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/07\/LED-street-light.jpg 780w, https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/07\/LED-street-light.jpg 360w\" sizes=\"auto, (max-width: 480px) 150px\" src=\"https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/07\/LED-street-light.jpg\" alt=\"\" class=\"uag-image-1145\" width=\"300\" height=\"300\" title=\"LED-street-light\" loading=\"lazy\" role=\"img\"><\/a><\/figure><\/div>\n<\/div>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-6a60882c alignfull uagb-is-root-container\"><div class=\"uagb-container-inner-blocks-wrap\">\n<div class=\"wp-block-uagb-container uagb-block-f1e91a35\">\n<h4 class=\"wp-block-heading has-text-align-center\"><a href=\"https:\/\/led.amasly.com\/ro\/products\/\">Lumini de inunda\u021bie cu LED<\/a><\/h4>\n<\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-165bfa58\">\n<h4 class=\"wp-block-heading has-text-align-center\"><a href=\"https:\/\/led.amasly.com\/ro\/products\/\">Lumini LED Tri-Proof Tube<\/a><\/h4>\n<\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-f6096e3b\">\n<h4 class=\"wp-block-heading has-text-align-center\"><a href=\"https:\/\/led.amasly.com\/ro\/products\/\">Lumini stradale cu LED<\/a><\/h4>\n<\/div>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-99c0e0a5 alignfull uagb-is-root-container\"><div class=\"uagb-container-inner-blocks-wrap\"><\/div><\/div>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>","protected":false},"excerpt":{"rendered":"<p>What is the principle of explosion proof? Explosion protection (explosion protection) refers to the ability to resist the impact of the explosion and heat without loss of normal operation is called explosion protection, to prevent the generation of explosions must be considered from the three necessary conditions, limiting one of the necessary conditions to limit [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":2374,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_uag_custom_page_level_css":"","site-sidebar-layout":"no-sidebar","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"disabled","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"enabled","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"class_list":["post-3014","page","type-page","status-publish","hentry"],"uagb_featured_image_src":{"full":false,"thumbnail":false,"medium":false,"medium_large":false,"large":false,"1536x1536":false,"2048x2048":false,"trp-custom-language-flag":false},"uagb_author_info":{"display_name":"Joe","author_link":"https:\/\/led.amasly.com\/ro\/author\/jacklin\/"},"uagb_comment_info":0,"uagb_excerpt":"What is the principle of explosion proof? Explosion protection (explosion protection) refers to the ability to resist the impact of the explosion and heat without loss of normal operation is called explosion protection, to prevent the generation of explosions must be considered from the three necessary conditions, limiting one of the necessary conditions to limit&hellip;","_links":{"self":[{"href":"https:\/\/led.amasly.com\/ro\/wp-json\/wp\/v2\/pages\/3014","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/led.amasly.com\/ro\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/led.amasly.com\/ro\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/led.amasly.com\/ro\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/led.amasly.com\/ro\/wp-json\/wp\/v2\/comments?post=3014"}],"version-history":[{"count":1,"href":"https:\/\/led.amasly.com\/ro\/wp-json\/wp\/v2\/pages\/3014\/revisions"}],"predecessor-version":[{"id":3019,"href":"https:\/\/led.amasly.com\/ro\/wp-json\/wp\/v2\/pages\/3014\/revisions\/3019"}],"up":[{"embeddable":true,"href":"https:\/\/led.amasly.com\/ro\/wp-json\/wp\/v2\/pages\/2374"}],"wp:attachment":[{"href":"https:\/\/led.amasly.com\/ro\/wp-json\/wp\/v2\/media?parent=3014"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}