{"id":2075,"date":"2025-02-28T21:49:24","date_gmt":"2025-02-28T13:49:24","guid":{"rendered":"https:\/\/led.amasly.com\/?p=2075"},"modified":"2025-03-07T22:17:24","modified_gmt":"2025-03-07T14:17:24","slug":"normas-e-questoes-de-instalacao-de-caixas-de-distribuicao-a-prova-de-explosao","status":"publish","type":"post","link":"https:\/\/led.amasly.com\/pt\/equipamento-a-prova-de-explosao\/normas-e-questoes-de-instalacao-de-caixas-de-distribuicao-a-prova-de-explosao\/","title":{"rendered":"Normas de caixas de distribui\u00e7\u00e3o \u00e0 prova de explos\u00e3o e quest\u00f5es de instala\u00e7\u00e3o"},"content":{"rendered":"<h2 class=\"wp-block-heading\"><strong>P<\/strong><strong>reambular<\/strong><strong><\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Com o desenvolvimento cont\u00ednuo da ind\u00fastria, a possibilidade de utilizar caixas de distribui\u00e7\u00e3o \u00e0 prova de explos\u00e3o tamb\u00e9m est\u00e1 a aumentar.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">As caixas de distribui\u00e7\u00e3o \u00e0 prova de explos\u00e3o s\u00e3o principalmente utilizadas em minas de carv\u00e3o, quart\u00e9is de bombeiros, petr\u00f3leo, instala\u00e7\u00f5es petroqu\u00edmicas, t\u00eaxteis e outras <strong>locais inflam\u00e1veis e explosivos<\/strong>. Estes locais s\u00e3o mais propensos a acidentes de prote\u00e7\u00e3o. Por isso, na escolha da caixa de distribui\u00e7\u00e3o de energia, \u00e9 necess\u00e1rio prestar mais aten\u00e7\u00e3o \u00e0 prote\u00e7\u00e3o do equipamento.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Normas espec\u00edficas para caixas de distribui\u00e7\u00e3o \u00e0 prova de explos\u00e3o<\/strong><strong><\/strong><\/h2>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>I. Normas gerais da caixa de distribui\u00e7\u00e3o \u00e0 prova de explos\u00e3o<\/strong><strong><\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Indicadores tecnol\u00f3gicos de produ\u00e7\u00e3o de caixas de distribui\u00e7\u00e3o para satisfazer as especifica\u00e7\u00f5es e os requisitos de conce\u00e7\u00e3o, e em conformidade com as disposi\u00e7\u00f5es das normas de execu\u00e7\u00e3o do produto a produzir.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Todos os componentes e par\u00e2metros t\u00e9cnicos t\u00eam de cumprir os requisitos de conce\u00e7\u00e3o da norma nacional GB7251, a produ\u00e7\u00e3o de amostras tem de ser notificada \u00e0 unidade de constru\u00e7\u00e3o, supervis\u00e3o, unidade de constru\u00e7\u00e3o da aceita\u00e7\u00e3o do pessoal relevante antes da produ\u00e7\u00e3o total.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>II.<\/strong><strong>&nbsp;caixa de distribui\u00e7\u00e3o \u00e0 prova de explos\u00e3o parte do corpo da caixa<\/strong><strong><\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">A caixa de distribui\u00e7\u00e3o adopta uma caixa de a\u00e7o inoxid\u00e1vel (o material de a\u00e7o inoxid\u00e1vel \u00e9 Baosteel 304 ou superior), a cor \u00e9 de a\u00e7o inoxid\u00e1vel, a espessura da caixa n\u00e3o \u00e9 inferior a 4,0 mm.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>III.<\/strong><strong>&nbsp;componentes da caixa antideflagrante<\/strong><strong><\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Os componentes el\u00e9ctricos da caixa de distribui\u00e7\u00e3o\/gabinete devem cumprir as disposi\u00e7\u00f5es pertinentes e manter a sua dist\u00e2ncia el\u00e9ctrica e de fuga em condi\u00e7\u00f5es normais de utiliza\u00e7\u00e3o; os condutores e terminais sob tens\u00e3o expostos na caixa, a sua dist\u00e2ncia el\u00e9ctrica e de fuga ou a tens\u00e3o de resist\u00eancia ao impacto devem estar, pelo menos, em conformidade com as disposi\u00e7\u00f5es pertinentes dos componentes el\u00e9ctricos que lhes est\u00e3o diretamente ligados.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>VI.<\/strong><strong>&nbsp;linha de montagem do grupo de caixas de distribui\u00e7\u00e3o \u00e0 prova de explos\u00e3o<\/strong><strong><\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">A cablagem de todos os elementos de fixa\u00e7\u00e3o \u00e9 feita com pe\u00e7as galvanizadas, a cablagem secund\u00e1ria tem de ser feita com fio preto e a sequ\u00eancia da caixa tem de ser adicionada; a caixa de instrumentos de medi\u00e7\u00e3o no condutor deve ser de estanho bem esmaltado; a cablagem da caixa de distribui\u00e7\u00e3o em camadas deve ser considerada como uma entrada e sa\u00edda de troncos.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Os terminais dos interruptores devem corresponder \u00e0 sec\u00e7\u00e3o transversal do fio; a cablagem ap\u00f3s a instala\u00e7\u00e3o dos componentes deve ser ordenadamente organizada e atada num feixe com fita de nylon para ser fixada atr\u00e1s da placa.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Caixa de distribui\u00e7\u00e3o \u00e0 prova de explos\u00e3o: processo de utiliza\u00e7\u00e3o de tabus comuns<\/strong><strong><\/strong><\/h2>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>I. Utiliza\u00e7\u00e3o de materiais de madeira sem tratamento ign\u00edfugo<\/strong><strong><\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Consequ\u00eancias<\/strong>: caixa de distribui\u00e7\u00e3o \u00e0 prova de explos\u00e3o de ilumina\u00e7\u00e3o (placa) se for feita de madeira num local h\u00famido e poeirento, f\u00e1cil de moldar, vazamento; al\u00e9m disso, a caixa de madeira (placa) n\u00e3o passa pelo tratamento retardador de fogo, f\u00e1cil de causar um inc\u00eandio, \u00e9 um risco de seguran\u00e7a.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Medidas<\/strong>: A fim de garantir uma utiliza\u00e7\u00e3o segura, <strong>as caixas de distribui\u00e7\u00e3o (quadros) de ilumina\u00e7\u00e3o \u00e0 prova de explos\u00e3o s\u00e3o <\/strong>necess\u00e1rio <strong>n\u00e3o devem ser fabricados com materiais inflam\u00e1veis.<\/strong>&nbsp;Mesmo em locais secos e sem poeira, as caixas de distribui\u00e7\u00e3o (quadros) de madeira \u00e0 prova de explos\u00e3o devem ser retardadas antes de serem utilizadas.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>II.<\/strong><strong>&nbsp;a caixa de distribui\u00e7\u00e3o de energia no terreno n\u00e3o fez a inspe\u00e7\u00e3o<\/strong><strong><\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Consequ\u00eancias<\/strong>A caixa de distribui\u00e7\u00e3o \u00e0 prova de explos\u00e3o de ilumina\u00e7\u00e3o (quadro) sem inspe\u00e7\u00e3o, ap\u00f3s a instala\u00e7\u00e3o, muitas vezes encontrada em seu segundo andar sem parafusos de aterramento especiais, pequena se\u00e7\u00e3o transversal do fio de aterramento de prote\u00e7\u00e3o, existem aparelhos el\u00e9tricos que podem ser abertos porta e fio flex\u00edvel de cobre nu da estrutura de metal n\u00e3o \u00e9 uma conex\u00e3o confi\u00e1vel, fios e aparelhos el\u00e9tricos n\u00e3o est\u00e3o conectados a um s\u00f3lido, h\u00e1 o fen\u00f4meno de anti-loop. Os parafusos e as porcas n\u00e3o requerem pe\u00e7as galvanizadas e o di\u00e2metro do fio n\u00e3o cumpre os requisitos. N\u00e3o existe uma etiqueta com c\u00f3digo de cores nem um arm\u00e1rio de cart\u00f5es ou diagramas de circuitos el\u00e9ctricos. A disposi\u00e7\u00e3o e o espa\u00e7amento dos aparelhos el\u00e9ctricos n\u00e3o s\u00e3o razo\u00e1veis, e as altera\u00e7\u00f5es ao calend\u00e1rio atrasado tamb\u00e9m afectar\u00e3o a qualidade.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Medidas<\/strong>: em primeiro lugar, no processamento de encomendas, aos fabricantes de requisitos t\u00e9cnicos em conformidade com a conce\u00e7\u00e3o e normas e padr\u00f5es, os fabricantes para produzir amostras, inspe\u00e7\u00e3o e reprodu\u00e7\u00e3o depois de passar; produtos no campo, deve estar em estrita conformidade com a conce\u00e7\u00e3o, normas e padr\u00f5es dos requisitos da inspe\u00e7\u00e3o e aceita\u00e7\u00e3o, para confirmar que a instala\u00e7\u00e3o depois de passar.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>III.<\/strong><strong>&nbsp;a instala\u00e7\u00e3o n\u00e3o \u00e9 s\u00f3lida a eleva\u00e7\u00e3o n\u00e3o cumpre os requisitos<\/strong><strong><\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Consequ\u00eancia<\/strong>: A eleva\u00e7\u00e3o da instala\u00e7\u00e3o da caixa de distribui\u00e7\u00e3o \u00e0 prova de explos\u00e3o de ilumina\u00e7\u00e3o (painel) n\u00e3o est\u00e1 em conformidade com os regulamentos, a instala\u00e7\u00e3o n\u00e3o \u00e9 firme e a caixa n\u00e3o \u00e9 vertical. Quando instalado no escuro, as bordas em torno do painel n\u00e3o est\u00e3o perto da parede, afectando a utiliza\u00e7\u00e3o da fun\u00e7\u00e3o, a vista n\u00e3o \u00e9 boa.<\/p>\n\n\n\n<div class=\"wp-block-uagb-image uagb-block-fddb0dde wp-block-uagb-image--layout-default wp-block-uagb-image--effect-static wp-block-uagb-image--align-none\"><figure class=\"wp-block-uagb-image__figure\"><img decoding=\"async\" srcset=\"https:\/\/led.amasly.com\/wp-content\/uploads\/2025\/02\/\u56fe\u72471.png 310w, https:\/\/led.amasly.com\/wp-content\/uploads\/2025\/02\/\u56fe\u72471-161x300.png 161w\" sizes=\"auto, (max-width: 480px) 150px\" src=\"https:\/\/led.amasly.com\/wp-content\/uploads\/2025\/02\/\u56fe\u72471.png\" alt=\"\" class=\"uag-image-2076\" width=\"310\" height=\"578\" title=\"\u56fe\u72471\" loading=\"lazy\" role=\"img\"><\/figure><\/div>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Medidas<\/strong>: A eleva\u00e7\u00e3o deve cumprir os requisitos do projeto. Quando o projeto n\u00e3o \u00e9 especificado, a altura do bordo inferior da caixa de distribui\u00e7\u00e3o de ilumina\u00e7\u00e3o \u00e0 prova de explos\u00e3o a partir do solo deve ser de 1,5 m, e a altura do bordo inferior do quadro de distribui\u00e7\u00e3o de ilumina\u00e7\u00e3o a partir do solo deve ser de 1,8 m. A caixa de distribui\u00e7\u00e3o \u00e0 prova de explos\u00e3o de ilumina\u00e7\u00e3o (placa) deve ser instalada de forma segura, e o desvio permitido da perpendicularidade da instala\u00e7\u00e3o n\u00e3o deve ser superior a 3 mm, e n\u00e3o deve haver lacunas ao redor da caixa de distribui\u00e7\u00e3o \u00e0 prova de explos\u00e3o quando ela \u00e9 instalada no escuro, as bordas do painel ao redor do painel devem estar pr\u00f3ximas \u00e0 parede, e as partes de contato do corpo da caixa e os edif\u00edcios e estruturas devem ser revestidas com tinta anticorrosiva. Deve ser aplicada tinta anti-corros\u00e3o.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>IV.<\/strong><strong>&nbsp;a linha de caixa cruzada desarrumada n\u00e3o agrupada num feixe<\/strong><strong><\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Consequ\u00eancias<\/strong>A cablagem na caixa de distribui\u00e7\u00e3o \u00e0 prova de explos\u00e3o de ilumina\u00e7\u00e3o (quadro) \u00e9 confusa, e o segundo quadro na caixa pressiona contra a abertura do tubo, o que afecta a entrada dos fios na caixa. Se for for\u00e7ado a apertar, o isolamento do fio ser\u00e1 danificado com o tempo, resultando facilmente num curto-circuito. E tornar a manuten\u00e7\u00e3o inconveniente, afetar a vista.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Medidas<\/strong>A caixa de distribui\u00e7\u00e3o \u00e0 prova de explos\u00e3o de ilumina\u00e7\u00e3o, utilizando caixas de metal, deve ser feita para evitar o tratamento contra a ferrugem e a corros\u00e3o; os orif\u00edcios de sa\u00edda da caixa n\u00e3o podem ser abertos com soldadura, um tubo com um orif\u00edcio, a rosca deve ser protegida antes dos orif\u00edcios da caixa de metal; as linhas est\u00e3o bem organizadas, a posi\u00e7\u00e3o da tubagem na caixa est\u00e1 razoavelmente organizada. N\u00e3o deixe a placa do segundo andar com a press\u00e3o do tubo demasiado apertada. Os fios da caixa devem ser colocados em linha reta \u00e0 volta da caixa e agrupados ordenadamente em feixes.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>V. N\u00e3o N, barramento PE na caixa el\u00e9ctrica<\/strong><strong><\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Consequ\u00eancia<\/strong>: Os barramentos N e PE n\u00e3o s\u00e3o colocados na caixa de distribui\u00e7\u00e3o \u00e0 prova de explos\u00e3o da ilumina\u00e7\u00e3o (quadro), o que n\u00e3o pode garantir o funcionamento seguro da linha.<\/p>\n\n\n\n<div class=\"wp-block-uagb-image uagb-block-2f51ad4a wp-block-uagb-image--layout-default wp-block-uagb-image--effect-static wp-block-uagb-image--align-none\"><figure class=\"wp-block-uagb-image__figure\"><a class=\"\" href=\"https:\/\/led.amasly.com\/pt\/\" target=\"\" rel=\"noopener\"><img decoding=\"async\" srcset=\"https:\/\/led.amasly.com\/wp-content\/uploads\/2025\/02\/\u56fe\u72472.png 486w, https:\/\/led.amasly.com\/wp-content\/uploads\/2025\/02\/\u56fe\u72472-275x300.png 275w\" sizes=\"auto, (max-width: 480px) 150px\" src=\"https:\/\/led.amasly.com\/wp-content\/uploads\/2025\/02\/\u56fe\u72472.png\" alt=\"\" class=\"uag-image-2077\" width=\"486\" height=\"531\" title=\"\u56fe\u72472\" loading=\"lazy\" role=\"img\"><\/a><\/figure><\/div>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Medidas<\/strong>: A caixa de distribui\u00e7\u00e3o (quadro) de ilumina\u00e7\u00e3o \u00e0 prova de explos\u00e3o \u00e9 instalada no barramento da linha zero (linha N) e da linha de liga\u00e7\u00e3o \u00e0 terra de prote\u00e7\u00e3o (linha PE), a linha zero e a linha de liga\u00e7\u00e3o \u00e0 terra de prote\u00e7\u00e3o devem ser ligadas ao barramento, n\u00e3o emendadas e numeradas.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>VI. Instala\u00e7\u00e3o de fus\u00edveis de parafuso com cablagem incorrecta<\/strong><strong><\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Consequ\u00eancia<\/strong>: O fus\u00edvel de parafuso instalado na caixa de distribui\u00e7\u00e3o \u00e0 prova de explos\u00e3o da ilumina\u00e7\u00e3o (quadro) n\u00e3o est\u00e1 ligado corretamente e o cabo de alimenta\u00e7\u00e3o est\u00e1 ligado ao terminal roscado, o que afecta a substitui\u00e7\u00e3o do n\u00facleo do fus\u00edvel. E uma opera\u00e7\u00e3o incorrecta pode facilmente levar a acidentes com choques el\u00e9ctricos.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Medidas<\/strong>: Para garantir a seguran\u00e7a, a linha de alimenta\u00e7\u00e3o do fus\u00edvel de parafuso instalado na caixa de distribui\u00e7\u00e3o \u00e0 prova de explos\u00e3o da ilumina\u00e7\u00e3o (quadro) deve ser ligada ao terminal do contacto central e a linha de carga deve ser ligada ao terminal roscado.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>VII.<\/strong><strong>&nbsp;a linha de prote\u00e7\u00e3o n\u00e3o est\u00e1 instalada o di\u00e2metro da linha n\u00e3o cumpre os requisitos<\/strong><strong><\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Consequ\u00eancias<\/strong>A linha de prote\u00e7\u00e3o da caixa de distribui\u00e7\u00e3o \u00e0 prova de explos\u00e3o de ilumina\u00e7\u00e3o (quadro) n\u00e3o est\u00e1 disposta a partir do terminal, mas pela estrutura da caixa em s\u00e9rie, o di\u00e2metro do fio n\u00e3o est\u00e1 definido de acordo com os requisitos, a tens\u00e3o da porta da caixa de distribui\u00e7\u00e3o \u00e0 prova de explos\u00e3o sobre a seguran\u00e7a do dispositivo n\u00e3o tem um solo de prote\u00e7\u00e3o, f\u00e1cil de ocorrer acidentes de seguran\u00e7a.<\/p>\n\n\n\n<div class=\"wp-block-uagb-image uagb-block-e20ecc1e wp-block-uagb-image--layout-default wp-block-uagb-image--effect-static wp-block-uagb-image--align-none\"><figure class=\"wp-block-uagb-image__figure\"><img decoding=\"async\" srcset=\"https:\/\/led.amasly.com\/wp-content\/uploads\/2025\/02\/\u56fe\u72473.png ,https:\/\/led.amasly.com\/wp-content\/uploads\/2025\/02\/\u56fe\u72473.png 780w, https:\/\/led.amasly.com\/wp-content\/uploads\/2025\/02\/\u56fe\u72473.png 360w\" sizes=\"auto, (max-width: 480px) 150px\" src=\"https:\/\/led.amasly.com\/wp-content\/uploads\/2025\/02\/\u56fe\u72473.png\" alt=\"\" class=\"uag-image-2078\" width=\"358\" height=\"336\" title=\"\u56fe\u72473\" loading=\"lazy\" role=\"img\"><\/figure><\/div>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Medidas<\/strong>: de acordo com os requisitos da especifica\u00e7\u00e3o, a caixa de distribui\u00e7\u00e3o (quadro) \u00e0 prova de explos\u00e3o da ilumina\u00e7\u00e3o deve ser instalada dentro do barramento de terra de prote\u00e7\u00e3o, o barramento deve ser ligado \u00e0 terra de prote\u00e7\u00e3o; a \u00e1rea da sec\u00e7\u00e3o transversal do fio de terra de prote\u00e7\u00e3o n\u00e3o deve ser inferior \u00e0 \u00e1rea da sec\u00e7\u00e3o transversal da fonte de alimenta\u00e7\u00e3o ao maior cabo dos aparelhos el\u00e9ctricos; mas tamb\u00e9m deve ser selecionada de acordo com as disposi\u00e7\u00f5es relevantes; a caixa de distribui\u00e7\u00e3o (quadro) \u00e0 prova de explos\u00e3o deve estar firme e bem ligada \u00e0 terra, <strong>deve existir um dispositivo de fecho<\/strong>; 50V ou mais do que a porta de abertura do equipamento el\u00e9trico, os pain\u00e9is m\u00f3veis devem ser ligados \u00e0 estrutura met\u00e1lica Good aterrada com uma liga\u00e7\u00e3o fi\u00e1vel de fio flex\u00edvel de cobre nu; a \u00e1rea da sec\u00e7\u00e3o transversal do fio de cobre nu tamb\u00e9m deve ser selecionada de acordo com as disposi\u00e7\u00f5es; a espessura da parede da caixa e da caixa de metal inferior a 2,5 mm n\u00e3o deve ser utilizada como linha de liga\u00e7\u00e3o \u00e0 terra transversal da tubagem e dos aparelhos el\u00e9ctricos para proteger a linha de liga\u00e7\u00e3o \u00e0 terra do ponto de contacto de press\u00e3o.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>VIII. Nome do circuito n\u00e3o indicado no trav\u00e3o<\/strong><strong><\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Consequ\u00eancia<\/strong>: O trav\u00e3o da caixa de distribui\u00e7\u00e3o \u00e0 prova de explos\u00e3o da ilumina\u00e7\u00e3o (quadro) n\u00e3o est\u00e1 identificado com o nome do circuito, o que traz inconvenientes para a utiliza\u00e7\u00e3o e manuten\u00e7\u00e3o.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Medidas<\/strong>: Geralmente, de acordo com os requisitos dos c\u00f3digos e normas, a porta da caixa de distribui\u00e7\u00e3o \u00e0 prova de explos\u00e3o de ilumina\u00e7\u00e3o (quadro) <strong>deve ser afixado com um diagrama do sistema de circuitos<\/strong>, O nome do circuito deve ser etiquetado no trav\u00e3o, especialmente quando h\u00e1 corrente alternada, corrente cont\u00ednua ou diferentes n\u00edveis de alimenta\u00e7\u00e3o na caixa de distribui\u00e7\u00e3o \u00e0 prova de explos\u00e3o da ilumina\u00e7\u00e3o (quadro), deve ser etiquetado claramente.<\/p>","protected":false},"excerpt":{"rendered":"<p>Preamble With the continuous development of industry, the chance of using explosion-proof distribution boxes is also rising. Explosion-proof distribution boxes are mainly used in coal mines, fire stations, petroleum, petrochemical installations and textile and other flammable and explosive places. These places are more prone to protection accidents. So in the choice of power distribution box [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_uag_custom_page_level_css":"","site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[8],"tags":[],"class_list":["post-2075","post","type-post","status-publish","format-standard","hentry","category-explosion-proof-equipment"],"uagb_featured_image_src":{"full":false,"thumbnail":false,"medium":false,"medium_large":false,"large":false,"1536x1536":false,"2048x2048":false,"trp-custom-language-flag":false},"uagb_author_info":{"display_name":"Joe","author_link":"https:\/\/led.amasly.com\/pt\/author\/jacklin\/"},"uagb_comment_info":0,"uagb_excerpt":"Preamble With the continuous development of industry, the chance of using explosion-proof distribution boxes is also rising. Explosion-proof distribution boxes are mainly used in coal mines, fire stations, petroleum, petrochemical installations and textile and other flammable and explosive places. These places are more prone to protection accidents. So in the choice of power distribution box&hellip;","_links":{"self":[{"href":"https:\/\/led.amasly.com\/pt\/wp-json\/wp\/v2\/posts\/2075","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/led.amasly.com\/pt\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/led.amasly.com\/pt\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/led.amasly.com\/pt\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/led.amasly.com\/pt\/wp-json\/wp\/v2\/comments?post=2075"}],"version-history":[{"count":2,"href":"https:\/\/led.amasly.com\/pt\/wp-json\/wp\/v2\/posts\/2075\/revisions"}],"predecessor-version":[{"id":2346,"href":"https:\/\/led.amasly.com\/pt\/wp-json\/wp\/v2\/posts\/2075\/revisions\/2346"}],"wp:attachment":[{"href":"https:\/\/led.amasly.com\/pt\/wp-json\/wp\/v2\/media?parent=2075"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/led.amasly.com\/pt\/wp-json\/wp\/v2\/categories?post=2075"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/led.amasly.com\/pt\/wp-json\/wp\/v2\/tags?post=2075"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}