{"id":1599,"date":"2024-12-29T15:20:47","date_gmt":"2024-12-29T07:20:47","guid":{"rendered":"https:\/\/led.amasly.com\/?p=1599"},"modified":"2024-12-29T15:21:07","modified_gmt":"2024-12-29T07:21:07","slug":"basic-requirements-for-bonding-joint-surfaces-of-flameproof-equipment-for-explosion-proof-lamps","status":"publish","type":"post","link":"https:\/\/led.amasly.com\/pt\/light\/basic-requirements-for-bonding-joint-surfaces-of-flameproof-equipment-for-explosion-proof-lamps\/","title":{"rendered":"Requisitos b\u00e1sicos para a colagem de superf\u00edcies de juntas de equipamentos antideflagrantes para l\u00e2mpadas \u00e0 prova de explos\u00e3o"},"content":{"rendered":"<p class=\"has-medium-font-size\">As superf\u00edcies de jun\u00e7\u00e3o coladas s\u00e3o uma forma estrutural comum no equipamento antideflagrante e s\u00e3o amplamente utilizadas em l\u00e2mpadas antideflagrantes, instrumentos antideflagrantes, caixas de controlo antideflagrantes e motores antideflagrantes. <\/p>\n\n\n\n<div class=\"wp-block-uagb-image uagb-block-e07c7a50 wp-block-uagb-image--layout-default wp-block-uagb-image--effect-static wp-block-uagb-image--align-none\"><figure class=\"wp-block-uagb-image__figure\"><a class=\"\" href=\"https:\/\/led.amasly.com\/pt\/\" target=\"\" rel=\"noopener\"><img decoding=\"async\" srcset=\"https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/12\/Explosion-proof-lights.jpg ,https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/12\/Explosion-proof-lights.jpg 780w, https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/12\/Explosion-proof-lights.jpg 360w\" sizes=\"auto, (max-width: 480px) 150px\" src=\"https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/12\/Explosion-proof-lights.jpg\" alt=\"\" class=\"uag-image-1600\" width=\"1008\" height=\"341\" title=\"Luzes \u00e0 prova de explos\u00e3o\" loading=\"lazy\" role=\"img\"><\/a><\/figure><\/div>\n\n\n\n<p class=\"has-medium-font-size\">I. Disposi\u00e7\u00f5es gerais Os componentes do inv\u00f3lucro antideflagrante podem ser colados diretamente \u00e0 parede do inv\u00f3lucro, formando um conjunto insepar\u00e1vel, ou colados a uma estrutura met\u00e1lica, de modo a que o conjunto possa ser substitu\u00eddo na sua totalidade sem danificar a liga\u00e7\u00e3o. <\/p>\n\n\n\n<p class=\"has-medium-font-size\">II. Resist\u00eancia mec\u00e2nica As superf\u00edcies das juntas coladas que fazem parte do inv\u00f3lucro antideflagrante apenas asseguram a veda\u00e7\u00e3o do inv\u00f3lucro. A estrutura deve ser tal que a resist\u00eancia mec\u00e2nica dos componentes n\u00e3o dependa apenas das propriedades adesivas do material de liga\u00e7\u00e3o. As portas ou coberturas que se prev\u00ea venham a ser abertas durante a manuten\u00e7\u00e3o ou a instala\u00e7\u00e3o n\u00e3o devem, aquando da sua abertura, provocar a falha do m\u00e9todo de fixa\u00e7\u00e3o mec\u00e2nica suplementar das superf\u00edcies das juntas coladas. <\/p>\n\n\n\n<p class=\"has-medium-font-size\">III. Materiais de liga\u00e7\u00e3o Os materiais de liga\u00e7\u00e3o devem ser capazes de suportar as condi\u00e7\u00f5es adversas de funcionamento exigidas. O limite inferior da temperatura de funcionamento cont\u00ednuo (COT) dos materiais de liga\u00e7\u00e3o n\u00e3o deve exceder a temperatura m\u00ednima de funcionamento e o limite superior deve ser, pelo menos, 20 K superior \u00e0 temperatura m\u00e1xima de funcionamento. <\/p>\n\n\n\n<p class=\"has-medium-font-size\">IV. Largura da superf\u00edcie da junta colada O trajeto mais curto atrav\u00e9s da superf\u00edcie da junta colada, do interior para o exterior do inv\u00f3lucro antideflagrante com um volume V, deve ser <\/p>\n\n\n\n<p class=\"has-medium-font-size\">- N\u00e3o inferior a 3 mm quando V \u2264 10 cm\u00b3; <\/p>\n\n\n\n<p class=\"has-medium-font-size\">- N\u00e3o inferior a 6 mm quando 10 cm\u00b3 &lt; V \u2264 100 cm\u00b3; <\/p>\n\n\n\n<p class=\"has-medium-font-size\">- N\u00e3o inferior a 10 mm quando V &gt; 100 cm\u00b3.<\/p>","protected":false},"excerpt":{"rendered":"<p>Bonded joint surfaces are a common structural form in flameproof equipment and are widely used in explosion-proof lamps, explosion-proof instruments, flameproof control boxes, and flameproof motors. I. General Provisions The components of the flameproof enclosure may be directly bonded to the enclosure wall to form an inseparable assembly, or bonded to a metal frame so [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":1600,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_uag_custom_page_level_css":"","site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"disabled","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[7],"tags":[],"class_list":["post-1599","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-light"],"uagb_featured_image_src":{"full":["https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/12\/Explosion-proof-lights.jpg",1008,341,false],"thumbnail":["https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/12\/Explosion-proof-lights-150x150.jpg",150,150,true],"medium":["https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/12\/Explosion-proof-lights-300x101.jpg",300,101,true],"medium_large":["https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/12\/Explosion-proof-lights-768x260.jpg",768,260,true],"large":["https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/12\/Explosion-proof-lights.jpg",1008,341,false],"1536x1536":["https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/12\/Explosion-proof-lights.jpg",1008,341,false],"2048x2048":["https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/12\/Explosion-proof-lights.jpg",1008,341,false],"trp-custom-language-flag":["https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/12\/Explosion-proof-lights.jpg",18,6,false]},"uagb_author_info":{"display_name":"Joe","author_link":"https:\/\/led.amasly.com\/pt\/author\/jacklin\/"},"uagb_comment_info":0,"uagb_excerpt":"Bonded joint surfaces are a common structural form in flameproof equipment and are widely used in explosion-proof lamps, explosion-proof instruments, flameproof control boxes, and flameproof motors. I. General Provisions The components of the flameproof enclosure may be directly bonded to the enclosure wall to form an inseparable assembly, or bonded to a metal frame so&hellip;","_links":{"self":[{"href":"https:\/\/led.amasly.com\/pt\/wp-json\/wp\/v2\/posts\/1599","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/led.amasly.com\/pt\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/led.amasly.com\/pt\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/led.amasly.com\/pt\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/led.amasly.com\/pt\/wp-json\/wp\/v2\/comments?post=1599"}],"version-history":[{"count":1,"href":"https:\/\/led.amasly.com\/pt\/wp-json\/wp\/v2\/posts\/1599\/revisions"}],"predecessor-version":[{"id":1601,"href":"https:\/\/led.amasly.com\/pt\/wp-json\/wp\/v2\/posts\/1599\/revisions\/1601"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/led.amasly.com\/pt\/wp-json\/wp\/v2\/media\/1600"}],"wp:attachment":[{"href":"https:\/\/led.amasly.com\/pt\/wp-json\/wp\/v2\/media?parent=1599"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/led.amasly.com\/pt\/wp-json\/wp\/v2\/categories?post=1599"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/led.amasly.com\/pt\/wp-json\/wp\/v2\/tags?post=1599"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}