{"id":1567,"date":"2024-12-26T22:55:25","date_gmt":"2024-12-26T14:55:25","guid":{"rendered":"https:\/\/led.amasly.com\/?p=1567"},"modified":"2024-12-28T14:53:07","modified_gmt":"2024-12-28T06:53:07","slug":"the-treatment-approaches-for-the-failure-of-explosion-proof-performance-of-explosion-proof-electrical-equipment","status":"publish","type":"post","link":"https:\/\/led.amasly.com\/pt\/explosion-proof-equipment\/the-treatment-approaches-for-the-failure-of-explosion-proof-performance-of-explosion-proof-electrical-equipment\/","title":{"rendered":"Abordagens de tratamento para a falha de desempenho \u00e0 prova de explos\u00e3o do equipamento el\u00e9trico \u00e0 prova de explos\u00e3o"},"content":{"rendered":"<p class=\"has-medium-font-size\">O ambiente de utiliza\u00e7\u00e3o do equipamento el\u00e9trico \u00e0 prova de explos\u00e3o \u00e9 normalmente muito corrosivo e agressivo. A manuten\u00e7\u00e3o regular do equipamento el\u00e9trico \u00e0 prova de explos\u00e3o \u00e9 uma tarefa crucial para garantir o seu desempenho sustentado e eficaz \u00e0 prova de explos\u00e3o. <\/p>\n\n\n\n<div class=\"wp-block-uagb-image uagb-block-d748ffbc wp-block-uagb-image--layout-default wp-block-uagb-image--effect-static wp-block-uagb-image--align-none\"><figure class=\"wp-block-uagb-image__figure\"><a class=\"\" href=\"https:\/\/led.amasly.com\/pt\/\" target=\"\" rel=\"noopener\"><img decoding=\"async\" srcset=\"https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/12\/Amasly-Explosion-proof-light-1024x576.png ,https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/12\/Amasly-Explosion-proof-light.png 780w, https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/12\/Amasly-Explosion-proof-light.png 360w\" sizes=\"auto, (max-width: 480px) 150px\" src=\"https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/12\/Amasly-Explosion-proof-light-1024x576.png\" alt=\"\" class=\"uag-image-1568\" width=\"1080\" height=\"607\" title=\"Luz \u00e0 prova de explos\u00e3o Amasly\" loading=\"lazy\" role=\"img\"><\/a><\/figure><\/div>\n\n\n\n<p class=\"has-medium-font-size\">I. Manuten\u00e7\u00e3o do material el\u00e9trico \u00e0 prova de explos\u00e3o Quando, durante a manuten\u00e7\u00e3o, se verificar que o desempenho \u00e0 prova de explos\u00e3o do material el\u00e9trico \u00e0 prova de explos\u00e3o se deteriorou ou falhou devido a danos provocados por for\u00e7as externas, corros\u00e3o atmosf\u00e9rica, corros\u00e3o qu\u00edmica, desgaste mec\u00e2nico, envelhecimento natural e outras raz\u00f5es, \u00e9 necess\u00e1rio proceder \u00e0 manuten\u00e7\u00e3o. A manuten\u00e7\u00e3o do equipamento el\u00e9trico \u00e0 prova de explos\u00e3o deve ser realizada de acordo com os regulamentos correspondentes. Se o grau de desempenho original \u00e0 prova de explos\u00e3o n\u00e3o puder ser restaurado ap\u00f3s a manuten\u00e7\u00e3o, pode ser tratado com base no desempenho t\u00e9cnico real, seguindo os princ\u00edpios abaixo: <\/p>\n\n\n\n<p class=\"has-medium-font-size\">1. Utilizar um grau de prote\u00e7\u00e3o contra explos\u00f5es inferior. <\/p>\n\n\n\n<p class=\"has-medium-font-size\">2. Converter para equipamento el\u00e9trico n\u00e3o \u00e0 prova de explos\u00e3o para utiliza\u00e7\u00e3o. <\/p>\n\n\n\n<p class=\"has-medium-font-size\">II. Falha do desempenho \u00e0 prova de explos\u00e3o do equipamento el\u00e9trico \u00e0 prova de explos\u00e3o Quando, durante a manuten\u00e7\u00e3o, se verifica que a estrutura e os par\u00e2metros do equipamento el\u00e9trico \u00e0 prova de explos\u00e3o foram alterados e que n\u00e3o est\u00e3o em conformidade com o tipo e a conce\u00e7\u00e3o originais \u00e0 prova de explos\u00e3o e n\u00e3o podem ser reparados, \u00e9 considerado uma falha e deve ser imediatamente desativado e substitu\u00eddo. Por exemplo: <\/p>\n\n\n\n<p class=\"has-medium-font-size\">1. A caixa do equipamento el\u00e9trico \u00e0 prova de fogo est\u00e1 muito deformada e n\u00e3o pode ser reparada. <\/p>\n\n\n\n<p class=\"has-medium-font-size\">2. A superf\u00edcie anti-deflagrante est\u00e1 muito danificada e n\u00e3o pode ser reparada. <\/p>\n\n\n\n<p class=\"has-medium-font-size\">3. A abertura \u00e0 prova de fogo excede a norma e n\u00e3o pode ser reparada. <\/p>\n\n\n\n<p class=\"has-medium-font-size\">4. O inv\u00f3lucro do equipamento el\u00e9trico \u00e0 prova de explos\u00e3o est\u00e1 rachado e n\u00e3o cumpre os requisitos do tipo original \u00e0 prova de explos\u00e3o.<\/p>\n\n\n\n<p><\/p>","protected":false},"excerpt":{"rendered":"<p>The usage environment of explosion-proof electrical equipment is typically highly corrosive and harsh. Regular maintenance of explosion-proof electrical equipment is a crucial task to guarantee its sustained and effective explosion-proof performance. I. Maintenance of Explosion-proof Electrical Equipment When it is discovered during maintenance that the explosion-proof performance of explosion-proof electrical equipment has deteriorated or failed [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":1568,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_uag_custom_page_level_css":"","site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"disabled","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[8],"tags":[],"class_list":["post-1567","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-explosion-proof-equipment"],"uagb_featured_image_src":{"full":["https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/12\/Amasly-Explosion-proof-light.png",1080,607,false],"thumbnail":["https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/12\/Amasly-Explosion-proof-light-150x150.png",150,150,true],"medium":["https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/12\/Amasly-Explosion-proof-light-300x169.png",300,169,true],"medium_large":["https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/12\/Amasly-Explosion-proof-light-768x432.png",768,432,true],"large":["https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/12\/Amasly-Explosion-proof-light-1024x576.png",1024,576,true],"1536x1536":["https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/12\/Amasly-Explosion-proof-light.png",1080,607,false],"2048x2048":["https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/12\/Amasly-Explosion-proof-light.png",1080,607,false],"trp-custom-language-flag":["https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/12\/Amasly-Explosion-proof-light.png",18,10,false]},"uagb_author_info":{"display_name":"Joe","author_link":"https:\/\/led.amasly.com\/pt\/author\/jacklin\/"},"uagb_comment_info":0,"uagb_excerpt":"The usage environment of explosion-proof electrical equipment is typically highly corrosive and harsh. Regular maintenance of explosion-proof electrical equipment is a crucial task to guarantee its sustained and effective explosion-proof performance. I. Maintenance of Explosion-proof Electrical Equipment When it is discovered during maintenance that the explosion-proof performance of explosion-proof electrical equipment has deteriorated or failed&hellip;","_links":{"self":[{"href":"https:\/\/led.amasly.com\/pt\/wp-json\/wp\/v2\/posts\/1567","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/led.amasly.com\/pt\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/led.amasly.com\/pt\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/led.amasly.com\/pt\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/led.amasly.com\/pt\/wp-json\/wp\/v2\/comments?post=1567"}],"version-history":[{"count":1,"href":"https:\/\/led.amasly.com\/pt\/wp-json\/wp\/v2\/posts\/1567\/revisions"}],"predecessor-version":[{"id":1569,"href":"https:\/\/led.amasly.com\/pt\/wp-json\/wp\/v2\/posts\/1567\/revisions\/1569"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/led.amasly.com\/pt\/wp-json\/wp\/v2\/media\/1568"}],"wp:attachment":[{"href":"https:\/\/led.amasly.com\/pt\/wp-json\/wp\/v2\/media?parent=1567"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/led.amasly.com\/pt\/wp-json\/wp\/v2\/categories?post=1567"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/led.amasly.com\/pt\/wp-json\/wp\/v2\/tags?post=1567"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}