{"id":2902,"date":"2025-04-03T21:06:33","date_gmt":"2025-04-03T13:06:33","guid":{"rendered":"https:\/\/led.amasly.com\/?page_id=2902"},"modified":"2025-04-03T21:06:38","modified_gmt":"2025-04-03T13:06:38","slug":"como-proteger-o-funcionamento-seguro-das-estacoes-de-servico-com-luminarias-a-prova-de-fogo-analise-exaustiva-e-programa-de-aplicacao","status":"publish","type":"page","link":"https:\/\/led.amasly.com\/pt\/conhecimento\/conhecimento-de-produtos-a-prova-de-explosao\/como-proteger-o-funcionamento-seguro-das-estacoes-de-servico-com-luminarias-a-prova-de-fogo-analise-exaustiva-e-programa-de-aplicacao\/","title":{"rendered":"Como proteger o funcionamento seguro das esta\u00e7\u00f5es de servi\u00e7o com uma lumin\u00e1ria \u00e0 prova de fogo? An\u00e1lise exaustiva e programa de aplica\u00e7\u00e3o"},"content":{"rendered":"\n<div class=\"wp-block-uagb-container uagb-block-27bae773 alignfull uagb-is-root-container\"><div class=\"uagb-container-inner-blocks-wrap\"><\/div><\/div>\n\n\n\n<h2 class=\"wp-block-heading has-text-align-left\"><strong>How to protect the safe operation of gas stations with <\/strong><strong>flameproof lighting fixture<\/strong><strong>? Comprehensive analysis and application program<\/strong><strong><\/strong><\/h2>\n\n\n\n<div class=\"wp-block-uagb-image uagb-block-da1360b5 wp-block-uagb-image--layout-default wp-block-uagb-image--effect-static wp-block-uagb-image--align-none\"><figure class=\"wp-block-uagb-image__figure\"><a class=\"\" href=\"https:\/\/led.amasly.com\/\" target=\"\" rel=\"noopener\"><img decoding=\"async\" srcset=\"https:\/\/led.amasly.com\/wp-content\/uploads\/2025\/01\/LED-explosion-proof-flood-lights.png ,https:\/\/led.amasly.com\/wp-content\/uploads\/2025\/01\/LED-explosion-proof-flood-lights.png 780w, https:\/\/led.amasly.com\/wp-content\/uploads\/2025\/01\/LED-explosion-proof-flood-lights.png 360w\" sizes=\"auto, (max-width: 480px) 150px\" src=\"https:\/\/led.amasly.com\/wp-content\/uploads\/2025\/01\/LED-explosion-proof-flood-lights.png\" alt=\"\" class=\"uag-image-1675\" width=\"1004\" height=\"308\" title=\"LED explosion proof flood lights\" loading=\"lazy\" role=\"img\"><\/a><\/figure><\/div>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>First, why must gas stations use professional <\/strong><strong>flameproof lighting fixture<\/strong><strong>?<\/strong><strong><\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Gas station as a flammable and explosive places [gasoline vapor explosion limit of 1.4%-7.6%], ordinary lighting equipment in the static buildup or circuit failure may cause deflagration accident.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Professional flameproof lighting fixture&nbsp;approved flame retardant engineering plastics [oxygen index \u2265 32] and cast aluminum explosion-proof shell combination, with triple overload care mechanism, can reduce the probability of electrical ignition source caused by accidents by 87% [according to the NFPA 30B guidelines test data], is the mandatory safety configuration of hazardous places lighting.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Second, <\/strong><strong>flameproof lighting fixture<\/strong><strong>&nbsp;6 core technology guidelines<\/strong><strong><\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">1. Composite explosion-proof structure: Ex d IIB T4 explosion-proof certification + IP66 protection level, to prevent the penetration of oil and gas and control the internal explosion energy.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">2. Dynamic temperature monitoring: Built-in PT100 temperature sensor, automatically start the secondary cooling system when the shell temperature reaches 85\u2103.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">3. Antistatic surface treatment: surface resistance value is controlled in the range of 10^6-10^9\u03a9 (in accordance with <a href=\"http:\/\/www.iecex-certs.com\/\" rel=\"nofollow noopener\" target=\"_blank\">IEC 60079-0 guidelines<\/a>), eliminating the risk of static electricity ignition.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">4. Emergency lighting system: 0.3 seconds after the interruption of the main power supply to switch to the backup power supply, continuous power supply \u2265 120 minutes<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">5. Corrosion-resistant coating: Approved for 720 hours salt spray test nano-ceramic coating, resistant to oil vapor corrosion<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">6. non-sparking wiring design: spring-loaded compression terminals, to avoid sparks caused by tool collision during installation.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Third, the key areas of gas station lighting program design<\/strong><strong><\/strong><\/h2>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>1. refueling operation area<\/strong><strong><\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Installation of anti-glare fireproof floodlighting lamps and lanterns [80-150W], equipped with tempered glass prismatic diffuser, vertical illuminance \u2265 200lux, horizontal uniformity of 0.7 or more<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>2. oil storage tank area<\/strong><strong><\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Explosion-proof fireproof searchlight [Ex d IIC T6 certification], equipped with microwave sensing module, personnel enter the automatic lifting to 100% brightness<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>3. convenience stores and office areas<\/strong><strong><\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">The use of fire emergency integration of flat panel lights, color rendering index Ra&gt;90, color temperature 4000K, in line with GB 50034-2013 commercial lighting guidelines<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Fourth, the purchase of gas station <\/strong><strong>flameproof lighting fixture<\/strong><strong>&nbsp;5 core indicators<\/strong><strong><\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">1. Double certification system: must hold the national explosion-proof electrical certification [CNEx] and the international IECEx certification.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">2. Material test report: Require the supply of shell material GWFI [Scorch Wire Flammability Index] \u2265 960 \u2103 test certificate.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">3. Protection performance verification: 72 hours of sealing test in the simulated oil and gas environment, internal humidity change \u2264 3% RH<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">4. Light decay control: 6000 hours of continuous operation at 55 \u2103 ambient temperature, luminous flux maintenance rate \u2265 95%.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">5. Convenience of maintenance: Requirements with no cover high-speed replacement of light source design, single maintenance time \u2264 15 minutes<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Fifth<\/strong><strong>. Installation specifications and safety management points<\/strong><strong><\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The horizontal distance between the lamps and the fuel dispenser is \u22654.5m [refer to GB 50156-2021 specification] The cable introduction port adopts the double thread explosion-proof structure, with the silicone rubber sealing ring compression device every month to use the combustible gas detector to check the oil and gas concentration around the lamps and lanterns within the range of 0.5m Quarterly to clean up the heat dissipation fins of the oil pollution, the use of pH-neutral special cleaning agent is strictly prohibited in the state of the equipment is electrified to carry out any dismantling operation.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>FAQ\uff1a<\/strong><strong>flameproof lighting fixture<\/strong><strong>&nbsp;in gas station common questions<\/strong><strong><\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Q1\uff1aDifference between&nbsp;flameproof lighting fixture&nbsp;and ordinary explosion-proof lamps?<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">A\uff1aFire-proof type focus on blocking the internal circuit fire to the outside, approved GB 3836.1-2021 guidelines; explosion-proof type of primary to prevent the intrusion of external explosions to meet the requirements of GB 12476.1. Gas stations should be selected with double protection characteristics of the product.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Q2\uff1aHow to verify the fire performance of lamps and lanterns on site?<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">A: Suppliers are required to implement the burning wire test demonstration: 850 \u2103 nickel-chrome wire contact lamps and lanterns non-metallic parts for 30 seconds, to observe whether to produce sustained combustion [Qualification guidelines: self-extinguishing open flame within 30 seconds].<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Q3: How to prevent leakage of electricity in rainy season?<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">A: Select the model with double insulation structure [Class II labeling], and ensure that the grounding resistance value &lt;0.1\u03a9. It is recommended to install a 30mA leakage protector.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Q4: How long is the equipment replacement cycle?<\/p>\n\n\n\n<p class=\"has-text-align-left wp-block-paragraph\">A: In the average daily working conditions of 18 hours, high-quality fire lighting should ensure: zero failure in the first 3 years, 5 years of light decay \u2264 8%, advocating the implementation of the sixth year of the overall safety assessment.<\/p>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-c7d898dd alignfull uagb-is-root-container\"><div class=\"uagb-container-inner-blocks-wrap\"><\/div><\/div>\n\n\n\n<h2 class=\"wp-block-heading\">Related Products<\/h2>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-66e4defc alignfull uagb-is-root-container\"><div class=\"uagb-container-inner-blocks-wrap\">\n<div class=\"wp-block-uagb-container uagb-block-a42945f9\">\n<div class=\"wp-block-uagb-image uagb-block-7296296b wp-block-uagb-image--layout-default wp-block-uagb-image--effect-static wp-block-uagb-image--align-none\"><figure class=\"wp-block-uagb-image__figure\"><a class=\"\" href=\"https:\/\/led.amasly.com\/products\/\" target=\"\" rel=\"noopener\"><img decoding=\"async\" srcset=\"https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/09\/Explosion-proof-high-bay-lights.png ,https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/09\/Explosion-proof-high-bay-lights.png 780w, https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/09\/Explosion-proof-high-bay-lights.png 360w\" sizes=\"auto, (max-width: 480px) 150px\" src=\"https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/09\/Explosion-proof-high-bay-lights.png\" alt=\"\" class=\"uag-image-1495\" width=\"300\" height=\"300\" title=\"Explosion proof high bay lights\" loading=\"lazy\" role=\"img\"><\/a><\/figure><\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-4d3efde5\">\n<div class=\"wp-block-uagb-image uagb-block-c9e90797 wp-block-uagb-image--layout-default wp-block-uagb-image--effect-static wp-block-uagb-image--align-none\"><figure class=\"wp-block-uagb-image__figure\"><a class=\"\" href=\"https:\/\/led.amasly.com\/products\/\" target=\"\" rel=\"noopener\"><img decoding=\"async\" srcset=\"https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/07\/LED-tri-proof-lights2.png ,https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/07\/LED-tri-proof-lights2.png 780w, https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/07\/LED-tri-proof-lights2.png 360w\" sizes=\"auto, (max-width: 480px) 150px\" src=\"https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/07\/LED-tri-proof-lights2.png\" alt=\"\" class=\"uag-image-1132\" width=\"300\" height=\"300\" title=\"LED-tri-proof-lights2\" loading=\"lazy\" role=\"img\"><\/a><\/figure><\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-11c2578b\">\n<div class=\"wp-block-uagb-image uagb-block-6e8883aa wp-block-uagb-image--layout-default wp-block-uagb-image--effect-static wp-block-uagb-image--align-none\"><figure class=\"wp-block-uagb-image__figure\"><a class=\"\" href=\"https:\/\/led.amasly.com\/products\/\" target=\"\" rel=\"noopener\"><img decoding=\"async\" srcset=\"https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/09\/LED-Explosion-Proof-Gas-Station-Light.png ,https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/09\/LED-Explosion-Proof-Gas-Station-Light.png 780w, https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/09\/LED-Explosion-Proof-Gas-Station-Light.png 360w\" sizes=\"auto, (max-width: 480px) 150px\" src=\"https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/09\/LED-Explosion-Proof-Gas-Station-Light.png\" alt=\"\" class=\"uag-image-1501\" width=\"300\" height=\"300\" title=\"LED Explosion Proof Gas Station Light\" loading=\"lazy\" role=\"img\"><\/a><\/figure><\/div>\n<\/div>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-548945b5 alignfull uagb-is-root-container\"><div class=\"uagb-container-inner-blocks-wrap\">\n<div class=\"wp-block-uagb-container uagb-block-967755d5\">\n<h4 class=\"wp-block-heading has-text-align-center\"><a href=\"https:\/\/led.amasly.com\/products\/\">LED Explosion Proof Lights<\/a><\/h4>\n<\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-9bc52fc2\">\n<h4 class=\"wp-block-heading has-text-align-center\"><a href=\"https:\/\/led.amasly.com\/products\/\">LED Tri-Proof Lights<\/a><\/h4>\n<\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-8ffa0a23\">\n<h4 class=\"wp-block-heading has-text-align-center\"><a href=\"https:\/\/led.amasly.com\/products\/\">Explosion Proof Gas Station Lights<\/a><\/h4>\n<\/div>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-29499fe0 alignfull uagb-is-root-container\"><div class=\"uagb-container-inner-blocks-wrap\">\n<div class=\"wp-block-uagb-container uagb-block-777ee1c7\">\n<div class=\"wp-block-uagb-image uagb-block-2e9a1851 wp-block-uagb-image--layout-default wp-block-uagb-image--effect-static wp-block-uagb-image--align-none\"><figure class=\"wp-block-uagb-image__figure\"><a class=\"\" href=\"https:\/\/led.amasly.com\/products\/\" target=\"\" rel=\"noopener\"><img decoding=\"async\" srcset=\"https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/10\/50W-100W-150W-200W-300W-LED-Flood-Light.jpg ,https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/10\/50W-100W-150W-200W-300W-LED-Flood-Light.jpg 780w, https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/10\/50W-100W-150W-200W-300W-LED-Flood-Light.jpg 360w\" sizes=\"auto, (max-width: 480px) 150px\" src=\"https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/10\/50W-100W-150W-200W-300W-LED-Flood-Light.jpg\" alt=\"\" class=\"uag-image-1526\" width=\"300\" height=\"300\" title=\"50W 100W 150W 200W 300W LED Flood Light\" loading=\"lazy\" role=\"img\"><\/a><\/figure><\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-af8c8683\">\n<div class=\"wp-block-uagb-image uagb-block-67947854 wp-block-uagb-image--layout-default wp-block-uagb-image--effect-static wp-block-uagb-image--align-none\"><figure class=\"wp-block-uagb-image__figure\"><a class=\"\" href=\"https:\/\/led.amasly.com\/products\/\" target=\"\" rel=\"noopener\"><img decoding=\"async\" srcset=\"https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/07\/led-tri-proof-light.png ,https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/07\/led-tri-proof-light.png 780w, https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/07\/led-tri-proof-light.png 360w\" sizes=\"auto, (max-width: 480px) 150px\" src=\"https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/07\/led-tri-proof-light.png\" alt=\"\" class=\"uag-image-1130\" width=\"300\" height=\"300\" title=\"led-tri-proof-light\" loading=\"lazy\" role=\"img\"><\/a><\/figure><\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-0fdfdd58\">\n<div class=\"wp-block-uagb-image uagb-block-1187d32d wp-block-uagb-image--layout-default wp-block-uagb-image--effect-static wp-block-uagb-image--align-none\"><figure class=\"wp-block-uagb-image__figure\"><a class=\"\" href=\"https:\/\/led.amasly.com\/products\/\" target=\"\" rel=\"noopener\"><img decoding=\"async\" srcset=\"https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/07\/LED-street-light.jpg ,https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/07\/LED-street-light.jpg 780w, https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/07\/LED-street-light.jpg 360w\" sizes=\"auto, (max-width: 480px) 150px\" src=\"https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/07\/LED-street-light.jpg\" alt=\"\" class=\"uag-image-1145\" width=\"300\" height=\"300\" title=\"LED-street-light\" loading=\"lazy\" role=\"img\"><\/a><\/figure><\/div>\n<\/div>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-6a60882c alignfull uagb-is-root-container\"><div class=\"uagb-container-inner-blocks-wrap\">\n<div class=\"wp-block-uagb-container uagb-block-f1e91a35\">\n<h4 class=\"wp-block-heading has-text-align-center\"><a href=\"https:\/\/led.amasly.com\/products\/\">LED Flood Lights<\/a><\/h4>\n<\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-165bfa58\">\n<h4 class=\"wp-block-heading has-text-align-center\"><a href=\"https:\/\/led.amasly.com\/products\/\">LED Tri-Proof Tube Lights<\/a><\/h4>\n<\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-f6096e3b\">\n<h4 class=\"wp-block-heading has-text-align-center\"><a href=\"https:\/\/led.amasly.com\/products\/\">LED Street Lights<\/a><\/h4>\n<\/div>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-99c0e0a5 alignfull uagb-is-root-container\"><div class=\"uagb-container-inner-blocks-wrap\"><\/div><\/div>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n","protected":false},"excerpt":{"rendered":"<p>How to protect the safe operation of gas stations with flameproof lighting fixture? Comprehensive analysis and application program First, why must gas stations use professional flameproof lighting fixture? Gas station as a flammable and explosive places [gasoline vapor explosion limit of 1.4%-7.6%], ordinary lighting equipment in the static buildup or circuit failure may cause deflagration [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":2374,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_uag_custom_page_level_css":"","site-sidebar-layout":"no-sidebar","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"disabled","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"enabled","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"class_list":["post-2902","page","type-page","status-publish","hentry"],"uagb_featured_image_src":{"full":false,"thumbnail":false,"medium":false,"medium_large":false,"large":false,"1536x1536":false,"2048x2048":false,"trp-custom-language-flag":false},"uagb_author_info":{"display_name":"Joe","author_link":"https:\/\/led.amasly.com\/pt\/author\/jacklin\/"},"uagb_comment_info":0,"uagb_excerpt":"How to protect the safe operation of gas stations with flameproof lighting fixture? Comprehensive analysis and application program First, why must gas stations use professional flameproof lighting fixture? Gas station as a flammable and explosive places [gasoline vapor explosion limit of 1.4%-7.6%], ordinary lighting equipment in the static buildup or circuit failure may cause deflagration&hellip;","_links":{"self":[{"href":"https:\/\/led.amasly.com\/pt\/wp-json\/wp\/v2\/pages\/2902","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/led.amasly.com\/pt\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/led.amasly.com\/pt\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/led.amasly.com\/pt\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/led.amasly.com\/pt\/wp-json\/wp\/v2\/comments?post=2902"}],"version-history":[{"count":1,"href":"https:\/\/led.amasly.com\/pt\/wp-json\/wp\/v2\/pages\/2902\/revisions"}],"predecessor-version":[{"id":2907,"href":"https:\/\/led.amasly.com\/pt\/wp-json\/wp\/v2\/pages\/2902\/revisions\/2907"}],"up":[{"embeddable":true,"href":"https:\/\/led.amasly.com\/pt\/wp-json\/wp\/v2\/pages\/2374"}],"wp:attachment":[{"href":"https:\/\/led.amasly.com\/pt\/wp-json\/wp\/v2\/media?parent=2902"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}