{"id":3061,"date":"2025-04-13T20:18:42","date_gmt":"2025-04-13T12:18:42","guid":{"rendered":"https:\/\/led.amasly.com\/?page_id=3061"},"modified":"2026-01-24T21:59:36","modified_gmt":"2026-01-24T13:59:36","slug":"zone-1-vs-division-1-how-explosion-proof-and-flame-proof-labels-impact-industrial-lighting-selection","status":"publish","type":"page","link":"https:\/\/led.amasly.com\/nl\/knowledge\/explosion-proof-products-knowledge\/zone-1-vs-division-1-how-explosion-proof-and-flame-proof-labels-impact-industrial-lighting-selection\/","title":{"rendered":"Zone 1 vs Divisie 1: hoe explosieveilige en vlamveilige labels de keuze van industri\u00eble verlichting be\u00efnvloeden"},"content":{"rendered":"<div class=\"wp-block-uagb-container uagb-block-27bae773 alignfull uagb-is-root-container\"><div class=\"uagb-container-inner-blocks-wrap\"><\/div><\/div>\n\n\n\n<h1 class=\"wp-block-heading has-text-align-center\"><strong>Zone 1 vs Divisie 1: hoe explosieveilige en vlamveilige labels de keuze van industri\u00eble verlichting be\u00efnvloeden<\/strong><\/h1>\n\n\n\n<div class=\"wp-block-uagb-image uagb-block-da1360b5 wp-block-uagb-image--layout-default wp-block-uagb-image--effect-static wp-block-uagb-image--align-none\"><figure class=\"wp-block-uagb-image__figure\"><img decoding=\"async\" srcset=\"https:\/\/led.amasly.com\/wp-content\/uploads\/2025\/01\/LED-explosion-proof-flood-lights.png ,https:\/\/led.amasly.com\/wp-content\/uploads\/2025\/01\/LED-explosion-proof-flood-lights.png 780w, https:\/\/led.amasly.com\/wp-content\/uploads\/2025\/01\/LED-explosion-proof-flood-lights.png 360w\" sizes=\"auto, (max-width: 480px) 150px\" src=\"https:\/\/led.amasly.com\/wp-content\/uploads\/2025\/01\/LED-explosion-proof-flood-lights.png\" alt=\"Explosion proof flood lights price, 12V explosion proof light, 40W explosion proof light, explosion proof led flood light\u00a0price, 140W explosion proof light, 110W explosion proof lights, 100W Flame Proof Lighting, LED Explosion proof Flood light, Explosion Proof and Flame Proof\" class=\"uag-image-1675\" width=\"1004\" height=\"308\" title=\"LED explosieveilige schijnwerpers\" loading=\"lazy\" role=\"img\"\/><\/figure><\/div>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Explosiebestendig en vlambestendig<\/strong>: <strong>Navigeren door wereldwijde normen voor naleving van gevaarlijke gebieden<\/strong><\/h2>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>Inleiding: De cruciale rol van classificatiesystemen<\/strong><strong><\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Industri\u00eble installaties die in gevaarlijke omgevingen werken, zoals olieraffinaderijen, chemische fabrieken en mijnbouw, zijn afhankelijk van nauwkeurige classificatiesystemen om explosierisico's te beperken.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">De voorwaarden&nbsp;<strong>Zone 1<\/strong>&nbsp;<a href=\"http:\/\/www.iecex-certs.com\/\" rel=\"nofollow noopener\" target=\"_blank\">(IEC\/ATEX<\/a>) en&nbsp;<a href=\"http:\/\/www.ul.com\" rel=\"nofollow noopener\" target=\"_blank\"><strong>Divisie 1<\/strong>&nbsp;(NEC)<\/a> defini\u00ebren verschillende benaderingen voor het classificeren van explosieve omgevingen, die rechtstreeks van invloed zijn op de keuze van explosieveilige (Ex d) en vlambestendige verlichtingsoplossingen.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Dit artikel ontcijfert deze normen, hun materiaaleisen en hun praktische implicaties voor het ontwerp van industri\u00eble verlichting.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>1. Zone 1 vs Divisie 1: belangrijkste verschillen in gevarenclassificatie<\/strong><strong><\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>A. Zone 1 (IEC\/ATEX-normen)<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Definitie<\/strong>: Zone 1 duidt gebieden aan waar een explosieve gasatmosfeer af en toe kan voorkomen tijdens normale werkzaamheden (bijvoorbeeld tijdens onderhoud of lekkages).<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Focus op certificering<\/strong>: ATEX\/IECEx legt de nadruk op&nbsp;<strong>explosie insluiting<\/strong>, waarvoor behuizingen nodig zijn die bestand zijn tegen interne ontploffingen zonder externe atmosferen te ontsteken.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Materiaalvereisten<\/strong>: Aluminium of roestvrijstalen behuizingen met vlambanen met openingen van \u22640,05 mm, getest volgens EN 60079-1 voor drukbestendigheid (\u22651,5x explosieve kracht).<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>B. Afdeling 1 (NEC 500\/505)<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Definitie<\/strong>: Divisie 1 is van toepassing op omgevingen waar gevaarlijke gassen, dampen of stof onder normale omstandigheden voortdurend of vaak aanwezig zijn.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Focus op certificering<\/strong>: UL 844 geeft prioriteit aan&nbsp;<strong>vlambestendigheid<\/strong>, Zorg ervoor dat externe oppervlakken bestand zijn tegen ontsteking door nabijgelegen branden.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Materiaalvereisten<\/strong>: Vlamvertragende polycarbonaat lenzen en epoxy afgedichte verbindingen om binnendringen van vlammen te voorkomen.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Belangrijkste contrast<\/strong>:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Risico Duur<\/strong>: Zone 1 richt zich op intermitterende gevaren, terwijl Divisie 1 zich richt op aanhoudende risico's.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Testprotocollen<\/strong>: Zone 1 armaturen ondergaan cyclische explosietests (5+ drukcycli), terwijl Divisie 1 lampen gericht zijn op continue blootstelling aan vlammen.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>2. Uitdagingen voor certificering: Regionale normen en materiaalinnovaties<\/strong><strong><\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>A. ATEX- vs NEC-conformiteit<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Europa (ATEX)<\/strong>: Verplicht dubbele certificering voor gecombineerde gas-\/stofgevaren (bijv. Zone 1\/21). Voorbeeld: QLEX-SLM-250-ATEX lichtbalken gebruiken polycarbonaat lenzen en aluminium behuizingen om te voldoen aan Ex d IIC T6 classificaties.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Noord-Amerika (NEC)<\/strong>: Divisie 1 lampen hebben vaak geen bescherming tegen stofontsteking (NFPA 70), waardoor een extra IP6X-afdichting nodig is voor graansilo's of farmaceutische installaties.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>B. Hybride oplossingen voor wereldwijde markten<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Casestudie<\/strong>: Vraag naar offshore olieplatforms&nbsp;<strong>ATEX Zone 1 + NEC Divisie 1<\/strong>&nbsp;naleving. De oplossingen omvatten drievoudig afgedichte LED modules met keramische vlamdovers, waardoor de onderhoudskosten met 30% dalen in zoutwateromgevingen.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Materiaaldoorbraken<\/strong>:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Geleidende Epoxy Pakkingen<\/strong>: Voorkom statische vonken in methaanrijke kolenmijnen van divisie 1.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Nano-keramische coatings<\/strong>: Verbeterde vlambestendigheid op aluminium behuizingen, getest tot 800\u00b0C voor LNG-opslagzones.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>3. Toepassingsspecifieke verlichtingsstrategie\u00ebn<\/strong><strong><\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>A. Olie- en gasinstallaties<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Zone 1<\/strong>: Gebruik explosieveilige LED-schijnwerpers met drukontlastingskleppen (bijv. GUANMN's Ex d-armaturen voor pijprekken in raffinaderijen).<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Divisie 1<\/strong>: Gebruik vlambestendige halogeen back-ups met oppervlaktetemperaturen &lt;85\u00b0C om te voorkomen dat waterstofsulfide ontbrandt.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>B. Chemische verwerkingsinstallaties<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Dubbele certificering<\/strong>: Brandbaar stof (Zone 21) en dampen (Divisie 1) vereisen armaturen met IP65 afdichting en Ex tD markeringen.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Faalgeval<\/strong>: Een brand in een fabriek in Texas in 2024 werd veroorzaakt door niet-ATEX-conforme divisie 1 lampen die smolten door blootstelling aan ethanoldamp.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>4. Kosten-batenanalyse: Overwegingen ten aanzien van totale eigendom<\/strong><strong><\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Initi\u00eble kosten<\/strong>: ATEX Zone 1 lampen kosten 20-35% meer door de precisiebewerking, maar verminderen de explosiegerelateerde uitvaltijd.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Onderhoud<\/strong>: De vlambestendige coatings van Divisie 1 vereisen driemaandelijkse infraroodinspecties (volgens ISA 60079-17), wat $1,200\/jaar per armatuur toevoegt.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>ROI Voorbeeld<\/strong>: Een petrochemische fabriek die overschakelde op dubbel gecertificeerde LED's rapporteerde 50% energiebesparing en 40% minder veiligheidsincidenten in 5 jaar.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>5. Toekomstige trends: Slimme technologie\u00ebn en duurzaamheid<\/strong><strong><\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Integratie van IoT<\/strong>: Sensoren die voldoen aan zone 1 bewaken methaanlekken en zorgen voor uitschakeling in &lt;0,5 seconden.<\/p>\n\n\n\n<p class=\"has-text-align-left wp-block-paragraph\"><strong>Vlamvertragers op biologische basis<\/strong>: Lignine-additieven vervangen giftige broomverbindingen en voldoen aan de REACH-regelgeving van de EU.<\/p>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-c7d898dd alignfull uagb-is-root-container\"><div class=\"uagb-container-inner-blocks-wrap\"><\/div><\/div>\n\n\n\n<h2 class=\"wp-block-heading\">Verwante producten<\/h2>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-66e4defc alignfull uagb-is-root-container\"><div class=\"uagb-container-inner-blocks-wrap\">\n<div class=\"wp-block-uagb-container uagb-block-a42945f9\">\n<div class=\"wp-block-uagb-image uagb-block-7296296b wp-block-uagb-image--layout-default wp-block-uagb-image--effect-static wp-block-uagb-image--align-none\"><figure class=\"wp-block-uagb-image__figure\"><a class=\"\" href=\"https:\/\/led.amasly.com\/nl\/products\/\" target=\"\" rel=\"noopener\"><img decoding=\"async\" srcset=\"https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/09\/Explosion-proof-high-bay-lights.png ,https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/09\/Explosion-proof-high-bay-lights.png 780w, https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/09\/Explosion-proof-high-bay-lights.png 360w\" sizes=\"auto, (max-width: 480px) 150px\" src=\"https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/09\/Explosion-proof-high-bay-lights.png\" alt=\"\" class=\"uag-image-1495\" width=\"300\" height=\"300\" title=\"Explosieveilige hoogbouwlampen\" loading=\"lazy\" role=\"img\"><\/a><\/figure><\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-4d3efde5\">\n<div class=\"wp-block-uagb-image uagb-block-c9e90797 wp-block-uagb-image--layout-default wp-block-uagb-image--effect-static wp-block-uagb-image--align-none\"><figure class=\"wp-block-uagb-image__figure\"><a class=\"\" href=\"https:\/\/led.amasly.com\/nl\/products\/\" target=\"\" rel=\"noopener\"><img decoding=\"async\" srcset=\"https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/07\/LED-tri-proof-lights2.png ,https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/07\/LED-tri-proof-lights2.png 780w, https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/07\/LED-tri-proof-lights2.png 360w\" sizes=\"auto, (max-width: 480px) 150px\" src=\"https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/07\/LED-tri-proof-lights2.png\" alt=\"\" class=\"uag-image-1132\" width=\"300\" height=\"300\" title=\"LED-drie-op-een-rij verlichting2\" loading=\"lazy\" role=\"img\"><\/a><\/figure><\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-11c2578b\">\n<div class=\"wp-block-uagb-image uagb-block-6e8883aa wp-block-uagb-image--layout-default wp-block-uagb-image--effect-static wp-block-uagb-image--align-none\"><figure class=\"wp-block-uagb-image__figure\"><a class=\"\" href=\"https:\/\/led.amasly.com\/nl\/products\/\" target=\"\" rel=\"noopener\"><img decoding=\"async\" srcset=\"https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/09\/LED-Explosion-Proof-Gas-Station-Light.png ,https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/09\/LED-Explosion-Proof-Gas-Station-Light.png 780w, https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/09\/LED-Explosion-Proof-Gas-Station-Light.png 360w\" sizes=\"auto, (max-width: 480px) 150px\" src=\"https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/09\/LED-Explosion-Proof-Gas-Station-Light.png\" alt=\"\" class=\"uag-image-1501\" width=\"300\" height=\"300\" title=\"LED explosieveilige benzinestationverlichting\" loading=\"lazy\" role=\"img\"><\/a><\/figure><\/div>\n<\/div>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-548945b5 alignfull uagb-is-root-container\"><div class=\"uagb-container-inner-blocks-wrap\">\n<div class=\"wp-block-uagb-container uagb-block-967755d5\">\n<h4 class=\"wp-block-heading has-text-align-center\"><a href=\"https:\/\/led.amasly.com\/nl\/products\/\">LED explosieveilige lampen<\/a><\/h4>\n<\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-9bc52fc2\">\n<h4 class=\"wp-block-heading has-text-align-center\"><a href=\"https:\/\/led.amasly.com\/nl\/products\/\">LED Tri-Proof lampen<\/a><\/h4>\n<\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-8ffa0a23\">\n<h4 class=\"wp-block-heading has-text-align-center\"><a href=\"https:\/\/led.amasly.com\/nl\/products\/\">Explosiebestendige lampen voor benzinestations<\/a><\/h4>\n<\/div>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-29499fe0 alignfull uagb-is-root-container\"><div class=\"uagb-container-inner-blocks-wrap\">\n<div class=\"wp-block-uagb-container uagb-block-777ee1c7\">\n<div class=\"wp-block-uagb-image uagb-block-2e9a1851 wp-block-uagb-image--layout-default wp-block-uagb-image--effect-static wp-block-uagb-image--align-none\"><figure class=\"wp-block-uagb-image__figure\"><a class=\"\" href=\"https:\/\/led.amasly.com\/nl\/products\/\" target=\"\" rel=\"noopener\"><img decoding=\"async\" srcset=\"https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/10\/50W-100W-150W-200W-300W-LED-Flood-Light.jpg ,https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/10\/50W-100W-150W-200W-300W-LED-Flood-Light.jpg 780w, https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/10\/50W-100W-150W-200W-300W-LED-Flood-Light.jpg 360w\" sizes=\"auto, (max-width: 480px) 150px\" src=\"https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/10\/50W-100W-150W-200W-300W-LED-Flood-Light.jpg\" alt=\"\" class=\"uag-image-1526\" width=\"300\" height=\"300\" title=\"50W 100W 150W 200W 300W LED Flood Light\" loading=\"lazy\" role=\"img\"><\/a><\/figure><\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-af8c8683\">\n<div class=\"wp-block-uagb-image uagb-block-67947854 wp-block-uagb-image--layout-default wp-block-uagb-image--effect-static wp-block-uagb-image--align-none\"><figure class=\"wp-block-uagb-image__figure\"><a class=\"\" href=\"https:\/\/led.amasly.com\/nl\/products\/\" target=\"\" rel=\"noopener\"><img decoding=\"async\" srcset=\"https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/07\/led-tri-proof-light.png ,https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/07\/led-tri-proof-light.png 780w, https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/07\/led-tri-proof-light.png 360w\" sizes=\"auto, (max-width: 480px) 150px\" src=\"https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/07\/led-tri-proof-light.png\" alt=\"\" class=\"uag-image-1130\" width=\"300\" height=\"300\" title=\"led-drie-veilig-licht\" loading=\"lazy\" role=\"img\"><\/a><\/figure><\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-0fdfdd58\">\n<div class=\"wp-block-uagb-image uagb-block-1187d32d wp-block-uagb-image--layout-default wp-block-uagb-image--effect-static wp-block-uagb-image--align-none\"><figure class=\"wp-block-uagb-image__figure\"><a class=\"\" href=\"https:\/\/led.amasly.com\/nl\/products\/\" target=\"\" rel=\"noopener\"><img decoding=\"async\" srcset=\"https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/07\/LED-street-light.jpg ,https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/07\/LED-street-light.jpg 780w, https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/07\/LED-street-light.jpg 360w\" sizes=\"auto, (max-width: 480px) 150px\" src=\"https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/07\/LED-street-light.jpg\" alt=\"\" class=\"uag-image-1145\" width=\"300\" height=\"300\" title=\"LED-straatverlichting\" loading=\"lazy\" role=\"img\"><\/a><\/figure><\/div>\n<\/div>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-6a60882c alignfull uagb-is-root-container\"><div class=\"uagb-container-inner-blocks-wrap\">\n<div class=\"wp-block-uagb-container uagb-block-f1e91a35\">\n<h4 class=\"wp-block-heading has-text-align-center\"><a href=\"https:\/\/led.amasly.com\/nl\/products\/\">LED overstromingslampen<\/a><\/h4>\n<\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-165bfa58\">\n<h4 class=\"wp-block-heading has-text-align-center\"><a href=\"https:\/\/led.amasly.com\/nl\/products\/\">LED Tri-Proof buislampen<\/a><\/h4>\n<\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-f6096e3b\">\n<h4 class=\"wp-block-heading has-text-align-center\"><a href=\"https:\/\/led.amasly.com\/nl\/products\/\">LED-straatverlichting<\/a><\/h4>\n<\/div>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-99c0e0a5 alignfull uagb-is-root-container\"><div class=\"uagb-container-inner-blocks-wrap\"><\/div><\/div>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>","protected":false},"excerpt":{"rendered":"<p>Zone 1 vs Division 1: How Explosion Proof and Flame Proof Labels Impact Industrial Lighting Selection Explosion Proof and Flame Proof: Navigating Global Standards for Hazardous Area Compliance Introduction: The Critical Role of Classification Systems Industrial facilities operating in hazardous environments\u2014such as oil refineries, chemical plants, and mining operations\u2014rely on precise classification systems to mitigate [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":2374,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_uag_custom_page_level_css":"","site-sidebar-layout":"no-sidebar","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"disabled","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"enabled","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"class_list":["post-3061","page","type-page","status-publish","hentry"],"uagb_featured_image_src":{"full":false,"thumbnail":false,"medium":false,"medium_large":false,"large":false,"1536x1536":false,"2048x2048":false,"trp-custom-language-flag":false},"uagb_author_info":{"display_name":"Joe","author_link":"https:\/\/led.amasly.com\/nl\/author\/jacklin\/"},"uagb_comment_info":0,"uagb_excerpt":"Zone 1 vs Division 1: How Explosion Proof and Flame Proof Labels Impact Industrial Lighting Selection Explosion Proof and Flame Proof: Navigating Global Standards for Hazardous Area Compliance Introduction: The Critical Role of Classification Systems Industrial facilities operating in hazardous environments\u2014such as oil refineries, chemical plants, and mining operations\u2014rely on precise classification systems to mitigate&hellip;","_links":{"self":[{"href":"https:\/\/led.amasly.com\/nl\/wp-json\/wp\/v2\/pages\/3061","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/led.amasly.com\/nl\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/led.amasly.com\/nl\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/led.amasly.com\/nl\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/led.amasly.com\/nl\/wp-json\/wp\/v2\/comments?post=3061"}],"version-history":[{"count":3,"href":"https:\/\/led.amasly.com\/nl\/wp-json\/wp\/v2\/pages\/3061\/revisions"}],"predecessor-version":[{"id":4723,"href":"https:\/\/led.amasly.com\/nl\/wp-json\/wp\/v2\/pages\/3061\/revisions\/4723"}],"up":[{"embeddable":true,"href":"https:\/\/led.amasly.com\/nl\/wp-json\/wp\/v2\/pages\/2374"}],"wp:attachment":[{"href":"https:\/\/led.amasly.com\/nl\/wp-json\/wp\/v2\/media?parent=3061"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}