{"id":3059,"date":"2025-04-13T20:28:58","date_gmt":"2025-04-13T12:28:58","guid":{"rendered":"https:\/\/led.amasly.com\/?page_id=3059"},"modified":"2025-04-13T20:29:04","modified_gmt":"2025-04-13T12:29:04","slug":"mythes-over-vlamveilige-verlichting-ontkracht-waarom-explosieveilige-verlichting-niet-altijd-veiliger-is","status":"publish","type":"page","link":"https:\/\/led.amasly.com\/nl\/kennis\/kennis-explosieveilige-producten\/mythes-over-vlamveilige-verlichting-ontkracht-waarom-explosieveilige-verlichting-niet-altijd-veiliger-is\/","title":{"rendered":"Mythes over vlambestendige verlichting ontkracht: Waarom \u201cexplosieveilig\u201d niet altijd veiliger is"},"content":{"rendered":"<div class=\"wp-block-uagb-container uagb-block-27bae773 alignfull uagb-is-root-container\"><div class=\"uagb-container-inner-blocks-wrap\"><\/div><\/div>\n\n\n\n<h2 class=\"wp-block-heading has-text-align-center\"><strong>Mythes over vlambestendige verlichting ontkracht: Waarom \u201cexplosieveilig\u201d niet altijd veiliger is<\/strong><strong><\/strong><\/h2>\n\n\n\n<div class=\"wp-block-uagb-image uagb-block-da1360b5 wp-block-uagb-image--layout-default wp-block-uagb-image--effect-static wp-block-uagb-image--align-none\"><figure class=\"wp-block-uagb-image__figure\"><a class=\"\" href=\"https:\/\/led.amasly.com\/nl\/\" target=\"\" rel=\"noopener\"><img decoding=\"async\" srcset=\"https:\/\/led.amasly.com\/wp-content\/uploads\/2025\/01\/LED-explosion-proof-flood-lights.png ,https:\/\/led.amasly.com\/wp-content\/uploads\/2025\/01\/LED-explosion-proof-flood-lights.png 780w, https:\/\/led.amasly.com\/wp-content\/uploads\/2025\/01\/LED-explosion-proof-flood-lights.png 360w\" sizes=\"auto, (max-width: 480px) 150px\" src=\"https:\/\/led.amasly.com\/wp-content\/uploads\/2025\/01\/LED-explosion-proof-flood-lights.png\" alt=\"\" class=\"uag-image-1675\" width=\"1004\" height=\"308\" title=\"LED explosieveilige schijnwerpers\" loading=\"lazy\" role=\"img\"><\/a><\/figure><\/div>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Ontmaskering van veelvoorkomende misvattingen over verlichting van gevaarlijke gebieden<\/strong><strong><\/strong><\/h2>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>Inleiding: De gevaarlijke aanname van gelijkwaardigheid<\/strong><strong><\/strong><\/h3>\n\n\n\n<p>De termen \u201cvlambestendig\u201d en \u201cexplosieveilig\u201d worden vaak door elkaar gebruikt in industri\u00eble verlichting, wat leidt tot kostbare en mogelijk catastrofale misverstanden.<\/p>\n\n\n\n<p>Hoewel beide certificeringen gericht zijn op het beperken van risico's in gevaarlijke omgevingen, vereisen hun technische verschillen - geworteld in materiaalwetenschap, regionale normen en toepassingsspecifieke vereisten - zorgvuldige bestudering.<\/p>\n\n\n\n<p>In dit artikel worden vijf wijdverbreide mythes ontkracht en wordt aan de hand van praktijkvoorbeelden en wereldwijde certificeringsgegevens duidelijk gemaakt waarom \u201cexplosieveilig\u201d alleen niet in alle scenario's veiligheid kan garanderen.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>1. Mythe 1: \u201cVlam- en explosieveilig zijn uitwisselbaar\u201d.\u201d<\/strong><strong><\/strong><\/h3>\n\n\n\n<p><strong>Werkelijkheid<\/strong>:<\/p>\n\n\n\n<p><strong>Explosieveilig (Ex d)<\/strong>: Richt zich op het indammen van interne explosies door middel van robuuste behuizingen (bijv. gegoten aluminium of roestvrij staal) die bestand zijn tegen een druk \u22651,5x de maximale explosiekracht.<\/p>\n\n\n\n<p><strong>Vlamdicht (FLP)<\/strong>: Geeft prioriteit aan het voorkomen van externe vlamverspreiding via vlamdovers en hittebestendige materialen (bijv. keramische coatings getest tot 800\u00b0C gedurende 30 seconden).<\/p>\n\n\n\n<p><strong>Casestudie<\/strong>:<br>Een brand in een raffinaderij in Texas in 2024 ontstond toen explosieveilige LED-behuizingen (UL 1203-gecertificeerd) niet bestand waren tegen externe vlammen als gevolg van een nabijgelegen waterstofsulfidelek. Analyse na het incident bracht aan het licht dat er brandvertragende lenscoatings ontbraken die vereist zijn volgens de ATEX Zone 1 normen.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>2. Mythe 2: \u201cE\u00e9n certificering voor alle regio's\u201d.\u201d<\/strong><strong><\/strong><\/h3>\n\n\n\n<p><strong>Opsplitsing regionale normen<\/strong>:<\/p>\n\n\n\n<p><strong>Noord-Amerika (<a href=\"http:\/\/www.ul.com\" rel=\"nofollow noopener\" target=\"_blank\">NEC\/UL<\/a>)<\/strong>: Explosieveilige verlichting (UL 844) domineert, maar het ontbreekt aan expliciete criteria voor vlambestendigheid voor Zone 22 stofomgevingen.<\/p>\n\n\n\n<p><strong>Europa (ATEX)<\/strong>: Verplicht dubbele naleving (EN 60079-1 voor explosies + EN 60332-1-2 voor vlambestendigheid) in Zone 1\/21 gebieden.<\/p>\n\n\n\n<p><strong>Wereldwijde markten<\/strong>: Bij IECEx-certificeringen worden vlamvoortplantingstests vaak weggelaten uit kosteneffici\u00ebntie, waardoor het risico bestaat dat niet aan de eisen wordt voldaan in hybride gas-\/stofinstallaties.<\/p>\n\n\n\n<p><strong>Voorbeeld<\/strong>:<br>GUANMN's explosieveilige schijnwerpers zijn UL-gecertificeerd, maar vereisen extra keramische vlambuizen om te voldoen aan de ATEX-normen voor Europese LNG-terminals.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>3. Mythe 3: \u201cMateriaalkeuze heeft geen invloed op de vlambestendigheid\u201d.\u201d<\/strong><strong><\/strong><\/h3>\n\n\n\n<p><strong>Kritische materiaalverschillen<\/strong>:<\/p>\n\n\n\n<p><strong>Gegoten aluminium<\/strong>: Ideaal voor het insluiten onder druk, maar gevoelig voor smelten bij langdurige blootstelling aan vlammen (bijv. 400\u00b0C aanhoudende hitte vervormt UL 1203 behuizingen).<\/p>\n\n\n\n<p><strong>Keramisch gecoat polycarbonaat<\/strong>: Blokkeert UV-straling en dooft vlammen zelf binnen 30 seconden (volgens IEC 60079-0), waardoor het essentieel is voor chemische fabrieken met ethanoldampen.<\/p>\n\n\n\n<p><strong>Innovatiekloof<\/strong>:<br>Veel fabrikanten geven voorrang aan explosiebeheersing boven vlambestendigheid om kosten te besparen en negeren nano-keramische coatings die beide eigenschappen verbeteren door 40% .<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>4. Mythe 4: \u201cOnderhoudsprotocollen zijn identiek voor beide systemen\u201d.\u201d<\/strong><strong><\/strong><\/h3>\n\n\n\n<p><strong>Onderhoud Divergentie<\/strong>:<\/p>\n\n\n\n<p><strong>Explosieveilig<\/strong>: Vereist jaarlijkse koppelcontroles van de bouten van de behuizing (tolerantie \u00b110% volgens ISA 60079-17) om druklekken te voorkomen.<\/p>\n\n\n\n<p><strong>Vlamdicht<\/strong>: Vereist driemaandelijkse infraroodthermografiescans om delaminatie in vlamvertragende lagen op te sporen.<\/p>\n\n\n\n<p><strong>Faalvoorbeeld<\/strong>:<br>Een kolenmijn in Australi\u00eb kreeg te maken met een methaanontsteking door ongecontroleerde degradatie van vlamwerende coatings op explosieveilige armaturen, waardoor de IECEx 60079-17 inspectie-intervallen werden overschreden.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>5. Mythe 5: \u201cExplosieveiligheid is voldoende voor nieuwe risico's zoals batterijopslag\u201d.\u201d<\/strong><strong><\/strong><\/h3>\n\n\n\n<p><strong>Gevaren van lithium-ionen<\/strong>:<\/p>\n\n\n\n<p><strong>Thermische uitloop<\/strong>: Explosieveilige behuizingen waarin batterijbranden voorkomen, slagen er vaak niet in om externe vlamuitbreiding te blokkeren, zoals te zien was bij een ESS-brand van 2024 waarbij de temperatuur boven de 1.000\u00b0C kwam.<\/p>\n\n\n\n<p><strong>Oplossing<\/strong>: Hybride ontwerpen die Ex d behuizingen integreren met vlamwerende gesinterde bronzen filters verminderen het risico op brandvoortplanting met 70%.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>Toekomstige trends: De veiligheidskloof overbruggen<\/strong><strong><\/strong><\/h3>\n\n\n\n<p><strong>Slimme sensoren<\/strong>: Vlamdetectoren met IoT-ondersteuning in combinatie met explosieveilige LED's verkorten de responstijd tot &lt;0,5 seconden in petrochemische zones.<\/p>\n\n\n\n<p class=\"has-text-align-left\"><strong>Duurzame materialen<\/strong>: Vlamvertragers op biologische basis (bijv. lignineadditieven) vervangen giftige halogenen en voldoen aan de REACH-regelgeving van de EU.<\/p>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-c7d898dd alignfull uagb-is-root-container\"><div class=\"uagb-container-inner-blocks-wrap\"><\/div><\/div>\n\n\n\n<h2 class=\"wp-block-heading\">Verwante producten<\/h2>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-66e4defc alignfull uagb-is-root-container\"><div class=\"uagb-container-inner-blocks-wrap\">\n<div class=\"wp-block-uagb-container uagb-block-a42945f9\">\n<div class=\"wp-block-uagb-image uagb-block-7296296b wp-block-uagb-image--layout-default wp-block-uagb-image--effect-static wp-block-uagb-image--align-none\"><figure class=\"wp-block-uagb-image__figure\"><a class=\"\" href=\"https:\/\/led.amasly.com\/nl\/producten\/\" target=\"\" rel=\"noopener\"><img decoding=\"async\" srcset=\"https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/09\/Explosion-proof-high-bay-lights.png ,https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/09\/Explosion-proof-high-bay-lights.png 780w, https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/09\/Explosion-proof-high-bay-lights.png 360w\" sizes=\"auto, (max-width: 480px) 150px\" src=\"https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/09\/Explosion-proof-high-bay-lights.png\" alt=\"\" class=\"uag-image-1495\" width=\"300\" height=\"300\" title=\"Explosieveilige hoogbouwlampen\" loading=\"lazy\" role=\"img\"><\/a><\/figure><\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-4d3efde5\">\n<div class=\"wp-block-uagb-image uagb-block-c9e90797 wp-block-uagb-image--layout-default wp-block-uagb-image--effect-static wp-block-uagb-image--align-none\"><figure class=\"wp-block-uagb-image__figure\"><a class=\"\" href=\"https:\/\/led.amasly.com\/nl\/producten\/\" target=\"\" rel=\"noopener\"><img decoding=\"async\" srcset=\"https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/07\/LED-tri-proof-lights2.png ,https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/07\/LED-tri-proof-lights2.png 780w, https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/07\/LED-tri-proof-lights2.png 360w\" sizes=\"auto, (max-width: 480px) 150px\" src=\"https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/07\/LED-tri-proof-lights2.png\" alt=\"\" class=\"uag-image-1132\" width=\"300\" height=\"300\" title=\"LED-drie-op-een-rij verlichting2\" loading=\"lazy\" role=\"img\"><\/a><\/figure><\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-11c2578b\">\n<div class=\"wp-block-uagb-image uagb-block-6e8883aa wp-block-uagb-image--layout-default wp-block-uagb-image--effect-static wp-block-uagb-image--align-none\"><figure class=\"wp-block-uagb-image__figure\"><a class=\"\" href=\"https:\/\/led.amasly.com\/nl\/producten\/\" target=\"\" rel=\"noopener\"><img decoding=\"async\" srcset=\"https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/09\/LED-Explosion-Proof-Gas-Station-Light.png ,https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/09\/LED-Explosion-Proof-Gas-Station-Light.png 780w, https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/09\/LED-Explosion-Proof-Gas-Station-Light.png 360w\" sizes=\"auto, (max-width: 480px) 150px\" src=\"https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/09\/LED-Explosion-Proof-Gas-Station-Light.png\" alt=\"\" class=\"uag-image-1501\" width=\"300\" height=\"300\" title=\"LED explosieveilige benzinestationverlichting\" loading=\"lazy\" role=\"img\"><\/a><\/figure><\/div>\n<\/div>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-548945b5 alignfull uagb-is-root-container\"><div class=\"uagb-container-inner-blocks-wrap\">\n<div class=\"wp-block-uagb-container uagb-block-967755d5\">\n<h4 class=\"wp-block-heading has-text-align-center\"><a href=\"https:\/\/led.amasly.com\/nl\/producten\/\">LED explosieveilige lampen<\/a><\/h4>\n<\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-9bc52fc2\">\n<h4 class=\"wp-block-heading has-text-align-center\"><a href=\"https:\/\/led.amasly.com\/nl\/producten\/\">LED Tri-Proof lampen<\/a><\/h4>\n<\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-8ffa0a23\">\n<h4 class=\"wp-block-heading has-text-align-center\"><a href=\"https:\/\/led.amasly.com\/nl\/producten\/\">Explosiebestendige lampen voor benzinestations<\/a><\/h4>\n<\/div>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-29499fe0 alignfull uagb-is-root-container\"><div class=\"uagb-container-inner-blocks-wrap\">\n<div class=\"wp-block-uagb-container uagb-block-777ee1c7\">\n<div class=\"wp-block-uagb-image uagb-block-2e9a1851 wp-block-uagb-image--layout-default wp-block-uagb-image--effect-static wp-block-uagb-image--align-none\"><figure class=\"wp-block-uagb-image__figure\"><a class=\"\" href=\"https:\/\/led.amasly.com\/nl\/producten\/\" target=\"\" rel=\"noopener\"><img decoding=\"async\" srcset=\"https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/10\/50W-100W-150W-200W-300W-LED-Flood-Light.jpg ,https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/10\/50W-100W-150W-200W-300W-LED-Flood-Light.jpg 780w, https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/10\/50W-100W-150W-200W-300W-LED-Flood-Light.jpg 360w\" sizes=\"auto, (max-width: 480px) 150px\" src=\"https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/10\/50W-100W-150W-200W-300W-LED-Flood-Light.jpg\" alt=\"\" class=\"uag-image-1526\" width=\"300\" height=\"300\" title=\"50W 100W 150W 200W 300W LED Flood Light\" loading=\"lazy\" role=\"img\"><\/a><\/figure><\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-af8c8683\">\n<div class=\"wp-block-uagb-image uagb-block-67947854 wp-block-uagb-image--layout-default wp-block-uagb-image--effect-static wp-block-uagb-image--align-none\"><figure class=\"wp-block-uagb-image__figure\"><a class=\"\" href=\"https:\/\/led.amasly.com\/nl\/producten\/\" target=\"\" rel=\"noopener\"><img decoding=\"async\" srcset=\"https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/07\/led-tri-proof-light.png ,https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/07\/led-tri-proof-light.png 780w, https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/07\/led-tri-proof-light.png 360w\" sizes=\"auto, (max-width: 480px) 150px\" src=\"https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/07\/led-tri-proof-light.png\" alt=\"\" class=\"uag-image-1130\" width=\"300\" height=\"300\" title=\"led-drie-veilig-licht\" loading=\"lazy\" role=\"img\"><\/a><\/figure><\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-0fdfdd58\">\n<div class=\"wp-block-uagb-image uagb-block-1187d32d wp-block-uagb-image--layout-default wp-block-uagb-image--effect-static wp-block-uagb-image--align-none\"><figure class=\"wp-block-uagb-image__figure\"><a class=\"\" href=\"https:\/\/led.amasly.com\/nl\/producten\/\" target=\"\" rel=\"noopener\"><img decoding=\"async\" srcset=\"https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/07\/LED-street-light.jpg ,https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/07\/LED-street-light.jpg 780w, https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/07\/LED-street-light.jpg 360w\" sizes=\"auto, (max-width: 480px) 150px\" src=\"https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/07\/LED-street-light.jpg\" alt=\"\" class=\"uag-image-1145\" width=\"300\" height=\"300\" title=\"LED-straatverlichting\" loading=\"lazy\" role=\"img\"><\/a><\/figure><\/div>\n<\/div>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-6a60882c alignfull uagb-is-root-container\"><div class=\"uagb-container-inner-blocks-wrap\">\n<div class=\"wp-block-uagb-container uagb-block-f1e91a35\">\n<h4 class=\"wp-block-heading has-text-align-center\"><a href=\"https:\/\/led.amasly.com\/nl\/producten\/\">LED overstromingslampen<\/a><\/h4>\n<\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-165bfa58\">\n<h4 class=\"wp-block-heading has-text-align-center\"><a href=\"https:\/\/led.amasly.com\/nl\/producten\/\">LED Tri-Proof buislampen<\/a><\/h4>\n<\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-f6096e3b\">\n<h4 class=\"wp-block-heading has-text-align-center\"><a href=\"https:\/\/led.amasly.com\/nl\/producten\/\">LED-straatverlichting<\/a><\/h4>\n<\/div>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-99c0e0a5 alignfull uagb-is-root-container\"><div class=\"uagb-container-inner-blocks-wrap\"><\/div><\/div>\n\n\n\n<p><\/p>","protected":false},"excerpt":{"rendered":"<p>Flame Proof Lighting Myths Debunked: Why &#8220;Explosion Proof&#8221; Isn&#8217;t Always Safer Unmasking Common Misconceptions in Hazardous Area Illumination Introduction: The Dangerous Assumption of Equivalence The terms &#8220;flame proof&#8221; and &#8220;explosion proof&#8221; are frequently conflated in industrial lighting, leading to costly and potentially catastrophic misunderstandings. While both certifications aim to mitigate risks in hazardous environments, their [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":2374,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_uag_custom_page_level_css":"","site-sidebar-layout":"no-sidebar","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"disabled","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"enabled","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"class_list":["post-3059","page","type-page","status-publish","hentry"],"uagb_featured_image_src":{"full":false,"thumbnail":false,"medium":false,"medium_large":false,"large":false,"1536x1536":false,"2048x2048":false,"trp-custom-language-flag":false},"uagb_author_info":{"display_name":"Joe","author_link":"https:\/\/led.amasly.com\/nl\/author\/jacklin\/"},"uagb_comment_info":0,"uagb_excerpt":"Flame Proof Lighting Myths Debunked: Why &#8220;Explosion Proof&#8221; Isn&#8217;t Always Safer Unmasking Common Misconceptions in Hazardous Area Illumination Introduction: The Dangerous Assumption of Equivalence The terms &#8220;flame proof&#8221; and &#8220;explosion proof&#8221; are frequently conflated in industrial lighting, leading to costly and potentially catastrophic misunderstandings. While both certifications aim to mitigate risks in hazardous environments, their&hellip;","_links":{"self":[{"href":"https:\/\/led.amasly.com\/nl\/wp-json\/wp\/v2\/pages\/3059","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/led.amasly.com\/nl\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/led.amasly.com\/nl\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/led.amasly.com\/nl\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/led.amasly.com\/nl\/wp-json\/wp\/v2\/comments?post=3059"}],"version-history":[{"count":1,"href":"https:\/\/led.amasly.com\/nl\/wp-json\/wp\/v2\/pages\/3059\/revisions"}],"predecessor-version":[{"id":3068,"href":"https:\/\/led.amasly.com\/nl\/wp-json\/wp\/v2\/pages\/3059\/revisions\/3068"}],"up":[{"embeddable":true,"href":"https:\/\/led.amasly.com\/nl\/wp-json\/wp\/v2\/pages\/2374"}],"wp:attachment":[{"href":"https:\/\/led.amasly.com\/nl\/wp-json\/wp\/v2\/media?parent=3059"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}