{"id":2134,"date":"2025-03-02T15:37:20","date_gmt":"2025-03-02T07:37:20","guid":{"rendered":"https:\/\/led.amasly.com\/?p=2134"},"modified":"2025-03-02T16:45:34","modified_gmt":"2025-03-02T08:45:34","slug":"what-explosion-protection-measures-are-available-for-industrial-buildings","status":"publish","type":"post","link":"https:\/\/led.amasly.com\/ms\/explosion-proof-equipment\/what-explosion-protection-measures-are-available-for-industrial-buildings\/","title":{"rendered":"Apakah langkah perlindungan letupan yang tersedia untuk bangunan perindustrian?"},"content":{"rendered":"<h1 class=\"wp-block-heading has-text-align-center\"><strong>Apakah langkah perlindungan letupan yang tersedia untuk bangunan perindustrian?<\/strong><strong><\/strong><\/h1>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Berkaitan <\/strong><strong>kod kebakaran bangunan am<\/strong><strong><\/strong><\/h2>\n\n\n\n<p>2.1.5 Susun atur proses pengeluaran dan kawalan proses pengeluaran di kilang, reka bentuk dan penyediaan peranti proses, peralatan dan instrumen, bahan, dan lain-lain hendaklah mengambil langkah pencegahan kebakaran dan kalis letupan yang sesuai mengikut bahaya kebakaran bahagian pengeluaran.<\/p>\n\n\n\n<p>2.1.7 Bangunan mengandungi gas mudah terbakar, wap, debu, serat di tempat atau bahagian yang berbahaya bagi letupan; langkah-langkah perlu diambil untuk mencegah pembentukan keadaan letupan; apabila menggunakan pelepasan tekanan, dekompresi, struktur anti-letupan atau langkah anti-letupan, ia hendaklah digunakan untuk memastikan struktur utama penyokong bangunan masih dapat menjalankan fungsi memikul beban walaupun terdedah kepada tekanan akibat pembakaran dan letupan.<\/p>\n\n\n\n<p>2.1.8 Dalam persekitaran yang mengandungi gas mudah terbakar, wap, debu, atau serat yang berpotensi menimbulkan bahaya letupan, peralatan dan paip yang boleh menjana elektrik statik hendaklah mempunyai keupayaan untuk mencegah berlakunya atau pengumpulan elektrik statik.<\/p>\n\n\n\n<p>2.1.9 Tempat atau bahagian bangunan yang mengeluarkan gas dan wap mudah terbakar yang lebih ringan daripada udara hendaklah mengambil langkah untuk menghalang pengumpulan gas dan wap mudah terbakar di dalam bangunan; tempat atau bahagian bangunan yang mengeluarkan gas dan wap mudah terbakar yang lebih berat daripada udara atau yang mempunyai risiko letupan debu atau serat hendaklah mematuhi peruntukan berikut:<\/p>\n\n\n\n<p>&nbsp; &nbsp;1 Lantai hendaklah mempunyai sifat tidak menghasilkan percikan, dan penutup lantai keseluruhan dengan bahan penebat hendaklah mempunyai sifat yang menghalang berlakunya elektrik statik;<\/p>\n\n\n\n<p>&nbsp; &nbsp;2 Debu dan serat mudah terbakar hendaklah diagihkan pada permukaan dalaman yang rata, licin dan mudah dibersihkan;<\/p>\n\n\n\n<p>&nbsp; &nbsp;3 Apabila saluran longkang dipasang di sebuah premis, langkah-langkah hendaklah diambil untuk menghalang pengumpulan gas mudah terbakar, wap, habuk dan serat dalam saluran longkang serta untuk menghalang penyebaran api melalui sambungan antara saluran longkang dan premis bersebelahan.<\/p>\n\n\n\n<p>Dengan bahaya letupan dalam pengeluaran, gudang harus mengambil langkah kalis letupan, kerana sekiranya letupan berlaku, ia bukan sahaja akan menyebabkan kerosakan pada bangunan, kemusnahan peralatan, korban jiwa, tetapi juga menyebabkan hentian pengeluaran, malah boleh menyebabkan letupan berantai pada bangunan atau kemudahan bersebelahan, mengakibatkan kebakaran sekunder, yang sememangnya sangat berbahaya, Oleh itu, pada peringkat awal reka bentuk seni bina, langkah-langkah anti-letupan perlu dipertimbangkan dan dikawal dengan ketat untuk menghapuskan semua bahaya tersembunyi, bagi melindungi keselamatan orang, rumah dan sebagainya;<\/p>\n\n\n\n<div class=\"wp-block-uagb-image uagb-block-9a73d38c wp-block-uagb-image--layout-default wp-block-uagb-image--effect-static wp-block-uagb-image--align-none\"><figure class=\"wp-block-uagb-image__figure\"><img decoding=\"async\" srcset=\"https:\/\/led.amasly.com\/wp-content\/uploads\/2025\/03\/\u56fe\u72474-1024x397.png ,https:\/\/led.amasly.com\/wp-content\/uploads\/2025\/03\/\u56fe\u72474.png 780w, https:\/\/led.amasly.com\/wp-content\/uploads\/2025\/03\/\u56fe\u72474.png 360w\" sizes=\"auto, (max-width: 480px) 150px\" src=\"https:\/\/led.amasly.com\/wp-content\/uploads\/2025\/03\/\u56fe\u72474-1024x397.png\" alt=\"\" class=\"uag-image-2135\" width=\"1080\" height=\"419\" title=\"Gambar 4\" loading=\"lazy\" role=\"img\"><\/figure><\/div>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Dan apakah langkah-langkah perlindungan letupan?<\/strong><strong><\/strong><\/h2>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>I. Rasionalisasi susun atur umum.<\/strong><strong><\/strong><\/h3>\n\n\n\n<p>Pertama sekali, terdapat risiko letupan pada loji A dan B. Elakkan pembinaan berhampiran sekolah, kawasan perumahan, hospital, muzium dan bangunan utama lain, lebuh raya, stesen penghantaran voltan tinggi dan sebagainya. Loji jenis ini hendaklah dibina di kawasan gunung atau menggunakan rintangan semula jadi seperti bukit kecil bagi menjimatkan pembinaan bendung kalis letupan dan mengurangkan bahaya kemalangan letupan.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>II. Pemasangan lapisan bunga tidak mudah terbakar<\/strong><strong><\/strong><\/h3>\n\n\n\n<p>Ia merujuk kepada lantai yang tidak menghasilkan percikan apabila ia terkena hentakan atau digosok oleh objek luar semasa proses pengeluaran dan penggunaan. Di beberapa tempat, bagi mengelakkan kebakaran dan letupan yang disebabkan oleh hentakan dan geseran objek berat yang jatuh, mesin yang bergerak, dan sebagainya, adalah perlu untuk menyediakan lantai yang tidak menghasilkan percikan. Jenis lantai ini biasanya diperbuat daripada marmar, dolomit, atau bahan lain.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>III. Pengudaraan kilang.<\/strong><strong><\/strong><\/h3>\n\n\n\n<p>Apabila gas yang mengandungi bahan mudah terbakar dilepaskan dari bengkel, loji hendaklah diberi pengudaraan untuk memastikan keselamatan, sistem pengudaraan kalis letupan hendaklah dipasang, dan bilah blower hendaklah diperbuat daripada bahan yang tidak akan menyebabkan kebakaran apabila disentuh. Pipa pengudaraan hendaklah dilengkapi plat penutup kalis api supaya sumber api dapat dipotong dengan cepat sekiranya berlaku kebakaran dan tidak merebak ke tempat lain.<\/p>\n\n\n\n<div class=\"wp-block-uagb-image uagb-block-1735bbc3 wp-block-uagb-image--layout-default wp-block-uagb-image--effect-static wp-block-uagb-image--align-none\"><figure class=\"wp-block-uagb-image__figure\"><a class=\"\" href=\"https:\/\/led.amasly.com\/ms\/\" target=\"\" rel=\"noopener\"><img decoding=\"async\" srcset=\"https:\/\/led.amasly.com\/wp-content\/uploads\/2025\/03\/\u56fe\u72476-1024x445.png ,https:\/\/led.amasly.com\/wp-content\/uploads\/2025\/03\/\u56fe\u72476.png 780w, https:\/\/led.amasly.com\/wp-content\/uploads\/2025\/03\/\u56fe\u72476.png 360w\" sizes=\"auto, (max-width: 480px) 150px\" src=\"https:\/\/led.amasly.com\/wp-content\/uploads\/2025\/03\/\u56fe\u72476-1024x445.png\" alt=\"\" class=\"uag-image-2136\" width=\"1080\" height=\"469\" title=\"Imej 6\" loading=\"lazy\" role=\"img\"><\/a><\/figure><\/div>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>IV<\/strong><strong>&nbsp;Ambil langkah untuk mengisolasi dan menyejukkan.<\/strong><strong><\/strong><\/h3>\n\n\n\n<p>Dalam cuaca panas musim panas yang lembap, radiasi matahari dan penghantaran haba akan menyebabkan suhu di dalam kilang meningkat. Peralatan pengeluaran di dalam kilang biasanya menghasilkan haba semasa proses pengeluaran. Bagi mengurangkan risiko letupan dan fenomena berbahaya di kilang, bumbung bangunan kilang dilapisi bahan penebat dan diberi rawatan penyejukan.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>V<\/strong><strong>, langkah anti-letupan yang baik.<\/strong><strong><\/strong><\/h3>\n\n\n\n<p>Oleh kerana sifat pengeluaran yang berbeza dan peralatan pengeluaran bagi loji yang berlainan, dinding dan tingkap serta pintu kalis letupan perlu dipasang untuk memisahkan susun atur. Sekiranya berlaku letupan, ia hanya dapat meminimumkan skop letupan dan mengurangkan bahaya yang timbul. Pemasangan dinding kalis letupan mesti mampu menahan gelombang kejutan dan pada masa yang sama mempunyai tahap ketahanan api tertentu.<\/p>\n\n\n\n<p>Ringkasnya, dengan pembangunan sosial dan ekonomi China, dan pada masa yang sama bagi terus memenuhi keperluan pembangunan masyarakat, bangunan industri akan semakin bertambah. Untuk memastikan keselamatan kakitangan, barangan dan alam sekitar, perhatian penuh perlu diberikan kepada keselamatan pembinaan bangunan industri. Dalam menghadapi pembinaan sebenar loji berbahaya letupan Kelas A dan B, langkah-langkah kalis letupan mesti diambil sepenuhnya sepanjang proses pembinaan.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Susun atur dan perlindungan terhadap letupan bagi loji dan gudang yang berbahaya berletupan<\/strong><strong><\/strong><\/h2>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>I. Susun atur umum<\/strong><strong><\/strong><\/h3>\n\n\n\n<p><strong>1. <\/strong>Terdapat risiko letupan bagi loji A dan B, gudang hendaklah didirikan secara berasingan, dan hendaklah terbuka atau separa terbuka, serta struktur penyokongnya hendaklah konkrit bertetulang atau rangka keluli dengan susunan berbaris.<\/p>\n\n\n\n<p><strong>2. <\/strong>Bahaya letupan susun atur loji adalah lebih baik berbentuk segi empat tepat, dan arah angin dominan hendaklah tegak atau pada sudut tidak kurang daripada 45\u00b0 supaya angin penembus dapat dimanfaatkan dengan berkesan untuk menyebarkan gas letupan. Di kawasan pergunungan, loji hendaklah ditempatkan di bahagian lereng yang menghadap arah angin dan di tempat yang pengudaraan baik.<\/p>\n\n\n\n<p><strong>3. <\/strong>Loji kalis letupan hendaklah dipasang secara berasingan; contohnya, ia mesti bersebelahan dengan loji yang tidak kalis letupan, hanya bersebelahan pada satu sisi, dan di antara kedua-duanya hendaklah terdapat dinding api atau dinding kalis letupan. Tidak seharusnya terdapat pintu terus antara kedua-dua loji bersebelahan bagi mengelakkan kesan gelombang kejutan letupan.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>II. Pelan lantai dan susun atur ruang<\/strong><strong><\/strong><\/h3>\n\n\n\n<h4 class=\"wp-block-heading\"><strong>1. Bilik kawalan utama dan bilik kawalan sampingan<\/strong><strong><\/strong><\/h4>\n\n\n\n<p>(1) Bilik kawalan umum bagi loji berbahaya letupan Kelas A dan B hendaklah disediakan secara berasingan.<\/p>\n\n\n\n<p>(2) Bilik kawalan kecil loji kelas A dan B yang berisiko letupan hendaklah ditubuhkan secara berasingan; apabila ditubuhkan bersebelahan dinding luaran, hendaklah menggunakan dinding pemisah kebakaran sekurang-kurangnya 3.00 jam kalis api dan pemisahan bagi bahagian lain.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\"><strong>2. Kawasan berbahaya meletup<\/strong><strong><\/strong><\/h4>\n\n\n\n<p>(1) Terdapat risiko letupan bagi bahagian pengeluaran A dan B; adalah sesuai untuk menempatkannya di kilang satu tingkat pada dinding luar kemudahan pelepasan tekanan, atau di kilang berbilang tingkat di tingkat atas sekali pada dinding luar kemudahan pelepasan tekanan yang berdekatan.<\/p>\n\n\n\n<p>(2) Terdapat risiko letupan; peralatan hendaklah dielakkan pada rasuk kilang, tiang dan komponen utama penahan beban lain dalam susun atur.<\/p>\n\n\n\n<p>(3) Ruang tangga, tangga luar atau kawasan dengan bahaya letupan dalam kawasan berbahaya letupan hendaklah dilengkapi dengan bakul pintu dan langkah perlindungan lain. Dinding pemisah bakul pintu hendaklah dinding pemisah kalis api dengan had ketahanan api tidak kurang daripada 2.00 jam, dan pintu hendaklah menggunakan pintu kalis api Kelas A serta dipasang secara berselang-seli dengan pintu ruang tangga.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\"><strong>3. Loji yang mengeluarkan gas mudah terbakar, wap mudah terbakar<\/strong><strong><\/strong><\/h4>\n\n\n\n<p>(1) Bagi loji Kategori A yang mengeluarkan gas mudah terbakar ringan dan wap mudah terbakar yang lebih ringan daripada udara, adalah sesuai menggunakan panel bumbung ringan sebagai kawasan pelepasan tekanan. Bumbung hendaklah sekampat mungkin dan bebas daripada ruang mati, serta ruang atas loji hendaklah dilengkapi pengudaraan yang baik.<\/p>\n\n\n\n<div class=\"wp-block-uagb-image uagb-block-4de77b89 wp-block-uagb-image--layout-default wp-block-uagb-image--effect-static wp-block-uagb-image--align-none\"><figure class=\"wp-block-uagb-image__figure\"><a class=\"\" href=\"https:\/\/amasly.com\/\" target=\"\" rel=\"noopener nofollow\"><img decoding=\"async\" srcset=\"https:\/\/led.amasly.com\/wp-content\/uploads\/2025\/03\/\u56fe\u724711-1024x708.png ,https:\/\/led.amasly.com\/wp-content\/uploads\/2025\/03\/\u56fe\u724711.png 780w, https:\/\/led.amasly.com\/wp-content\/uploads\/2025\/03\/\u56fe\u724711.png 360w\" sizes=\"auto, (max-width: 480px) 150px\" src=\"https:\/\/led.amasly.com\/wp-content\/uploads\/2025\/03\/\u56fe\u724711-1024x708.png\" alt=\"\" class=\"uag-image-2137\" width=\"1080\" height=\"747\" title=\"Gambar 11\" loading=\"lazy\" role=\"img\"><\/a><\/figure><\/div>\n\n\n\n<p>(2) Loji Kategori A yang mengeluarkan gas mudah terbakar dan wap mudah terbakar yang lebih berat daripada udara serta loji Kategori B yang mempunyai bahaya letupan habuk dan gentian hendaklah mematuhi peruntukan berikut:<\/p>\n\n\n\n<p>Lantai yang tidak menghasilkan percikan hendaklah digunakan. Langkah anti-statik hendaklah diambil apabila bahan penebat digunakan untuk keseluruhan permukaan.<\/p>\n\n\n\n<p>Permukaan dalaman kilang yang mengeluarkan habuk dan serat mudah terbakar hendaklah rata, licin dan mudah dibersihkan.<\/p>\n\n\n\n<p>Tidak sesuai memasang saluran di dalam loji; jika perlu, penutupnya hendaklah kemas. Saluran itu hendaklah mengambil langkah berkesan untuk menghalang pengumpulan gas mudah terbakar, wap mudah terbakar, habuk dan serat, serta hendaklah disegel dengan bahan kalis api pada sambungannya dengan loji bersebelahan.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\"><strong>4. Loji dan gudang di mana cecair kumpulan A, B dan C digunakan, dihasilkan atau disimpan<\/strong><strong><\/strong><\/h4>\n\n\n\n<p>(1) Saluran paip dan parit loji yang menggunakan dan menghasilkan cecair kategori A, B dan C tidak boleh disambungkan dengan saluran paip dan parit loji jiran, dan saluran pembuangan hendaklah dilengkapi dengan perangkap lemak.<\/p>\n\n\n\n<p>(2) Gudang untuk cecair kategori A, B dan C hendaklah dilengkapi dengan kemudahan untuk mencegah penyebaran cecair. Gudang bagi barangan yang akan terbakar dan meletup apabila basah hendaklah dilengkapi dengan langkah-langkah untuk mencegah penembesan air.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\"><strong>5. Bawah tanah, separa ruang bawah tanah<\/strong><strong><\/strong><\/h4>\n\n\n\n<p>(1) Tapak pengeluaran Kelas A dan B tidak seharusnya terletak di bawah tanah atau separa bawah tanah.<\/p>\n\n\n\n<p>(2) Gudang Kategori A dan B juga tidak seharusnya terletak di bawah tanah atau separa bawah tanah.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>III. Pelepasan tekanan<\/strong><strong><\/strong><\/h3>\n\n\n\n<p><strong>1. <\/strong>Kemudahan pelepasan tekanan hendaklah disediakan di loji yang berbahaya akibat letupan atau di bahagian loji yang berbahaya akibat letupan.<\/p>\n\n\n\n<p><strong>2. <\/strong>Kemudahan pelepasan tekanan hendaklah sesuai untuk panel bumbung ringan, dinding dan pintu serta tingkap ringan yang mudah melepaskan tekanan, dan hendaklah diperbuat daripada bahan yang tidak menghasilkan serpihan tajam sekiranya berlaku letupan, seperti kaca keselamatan.<\/p>\n\n\n\n<p><strong>3. <\/strong>Kemudahan pelepasan tekanan hendaklah ditubuhkan supaya mengelakkan kawasan berpenduduk padat dan jalan raya utama, serta hendaklah berhampiran dengan bahagian yang berisiko letupan.<\/p>\n\n\n\n<p><strong>4. <\/strong>Jisim panel bumbung ringan dan dinding yang digunakan sebagai kemudahan pelepasan tekanan tidak boleh melebihi 60 kg\/m2. Kemudahan pelepasan tekanan di atas bumbung hendaklah dilindungi daripada pengumpulan salji dan ais.<\/p>\n\n\n\n<p><strong>5. <\/strong>Untuk loji Kategori A yang mengeluarkan gas dan wap mudah terbakar yang lebih ringan daripada udara, adalah sesuai menggunakan panel bumbung ringan sebagai kawasan pelepasan tekanan. Bumbung hendaklah sekampat mungkin dan bebas daripada ruang mati, dan ruang atas loji hendaklah berventilasi dengan baik.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>IV. Pengiraan kawasan pelepasan tekanan<\/strong><strong><\/strong><\/h3>\n\n\n\n<div class=\"wp-block-uagb-image uagb-block-dce52116 wp-block-uagb-image--layout-default wp-block-uagb-image--effect-static wp-block-uagb-image--align-none\"><figure class=\"wp-block-uagb-image__figure\"><img decoding=\"async\" srcset=\"https:\/\/led.amasly.com\/wp-content\/uploads\/2025\/03\/\u56fe\u724716-1024x915.png ,https:\/\/led.amasly.com\/wp-content\/uploads\/2025\/03\/\u56fe\u724716.png 780w, https:\/\/led.amasly.com\/wp-content\/uploads\/2025\/03\/\u56fe\u724716.png 360w\" sizes=\"auto, (max-width: 480px) 150px\" src=\"https:\/\/led.amasly.com\/wp-content\/uploads\/2025\/03\/\u56fe\u724716-1024x915.png\" alt=\"\" class=\"uag-image-2138\" width=\"1080\" height=\"965\" title=\"Imej 16\" loading=\"lazy\" role=\"img\"><\/figure><\/div>\n\n\n\n<p>Formula pengiraan kawasan pelepasan tekanan:<\/p>\n\n\n\n<p>A=10CV2\/3<\/p>\n\n\n\n<p>A \u2013 Kawasan pelepasan tekanan (\u33a1);<\/p>\n\n\n\n<p>V \u2013 isipun kilang (m\u00b3);<\/p>\n\n\n\n<p>C \u2013 Nisbah pelepasan tekanan<\/p>\n\n\n\n<p>1) nisbah panjang-ke-diameter: dimensi terpanjang daripada dimensi geometri dataran bangunan dan perimeter keratan rentasnya, dibahagikan dengan 4.0 kali kawasan keratan rentas bangunan.<\/p>\n\n\n\n<p>2) Apabila nisbah L\/D loji melebihi 3, adalah digalakkan untuk membahagikan bangunan kepada beberapa bahagian pengiraan dengan nisbah L\/D tidak melebihi 3. Bahagian biasa dalam setiap bahagian pengiraan tidak boleh digunakan sebagai kawasan pelepasan tekanan.<\/p>\n\n\n\n<p>&nbsp; &nbsp; &nbsp; Pencegahan letupan bangunan perlu mengikut prinsip mengawal bahan mudah terbakar dan bahan yang membantu pembakaran, menghapuskan sumber penyalaan, dan menghentikan perkembangan kemalangan. Langkah pencegahan seperti mengecualikan bahan mudah terbakar dan menghapuskan sumber penyalaan, serta langkah mitigasi seperti pelepasan tekanan, struktur kalis letupan, dan susun atur yang rasional, diambil untuk mengurangkan risiko letupan.<\/p>","protected":false},"excerpt":{"rendered":"<p>What explosion protection measures are available for industrial buildings? Relevant general building fire codes 2.1.5 The layout of the production process and the control of the production process in the plant, the design and setup of the process devices, equipment and instrumentation, materials, etc., shall take appropriate fire prevention and explosion-proof measures in accordance with [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_uag_custom_page_level_css":"","site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[8],"tags":[],"class_list":["post-2134","post","type-post","status-publish","format-standard","hentry","category-explosion-proof-equipment"],"uagb_featured_image_src":{"full":false,"thumbnail":false,"medium":false,"medium_large":false,"large":false,"1536x1536":false,"2048x2048":false,"trp-custom-language-flag":false},"uagb_author_info":{"display_name":"Joe","author_link":"https:\/\/led.amasly.com\/ms\/author\/jacklin\/"},"uagb_comment_info":0,"uagb_excerpt":"What explosion protection measures are available for industrial buildings? Relevant general building fire codes 2.1.5 The layout of the production process and the control of the production process in the plant, the design and setup of the process devices, equipment and instrumentation, materials, etc., shall take appropriate fire prevention and explosion-proof measures in accordance with&hellip;","_links":{"self":[{"href":"https:\/\/led.amasly.com\/ms\/wp-json\/wp\/v2\/posts\/2134","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/led.amasly.com\/ms\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/led.amasly.com\/ms\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/led.amasly.com\/ms\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/led.amasly.com\/ms\/wp-json\/wp\/v2\/comments?post=2134"}],"version-history":[{"count":1,"href":"https:\/\/led.amasly.com\/ms\/wp-json\/wp\/v2\/posts\/2134\/revisions"}],"predecessor-version":[{"id":2139,"href":"https:\/\/led.amasly.com\/ms\/wp-json\/wp\/v2\/posts\/2134\/revisions\/2139"}],"wp:attachment":[{"href":"https:\/\/led.amasly.com\/ms\/wp-json\/wp\/v2\/media?parent=2134"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/led.amasly.com\/ms\/wp-json\/wp\/v2\/categories?post=2134"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/led.amasly.com\/ms\/wp-json\/wp\/v2\/tags?post=2134"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}