{"id":1567,"date":"2024-12-26T22:55:25","date_gmt":"2024-12-26T14:55:25","guid":{"rendered":"https:\/\/led.amasly.com\/?p=1567"},"modified":"2024-12-28T14:53:07","modified_gmt":"2024-12-28T06:53:07","slug":"the-treatment-approaches-for-the-failure-of-explosion-proof-performance-of-explosion-proof-electrical-equipment","status":"publish","type":"post","link":"https:\/\/led.amasly.com\/ms\/explosion-proof-equipment\/the-treatment-approaches-for-the-failure-of-explosion-proof-performance-of-explosion-proof-electrical-equipment\/","title":{"rendered":"Pendekatan Rawatan untuk Kegagalan Prestasi Kalis Letupan Peralatan Elektrik Kalis Letupan"},"content":{"rendered":"<p class=\"has-medium-font-size\">Persekitaran penggunaan peralatan elektrik kalis letupan biasanya sangat korosif dan keras. Penyelenggaraan berkala peralatan elektrik kalis letupan adalah tugas penting untuk menjamin prestasi kalis letupannya yang berterusan dan berkesan. <\/p>\n\n\n\n<div class=\"wp-block-uagb-image uagb-block-d748ffbc wp-block-uagb-image--layout-default wp-block-uagb-image--effect-static wp-block-uagb-image--align-none\"><figure class=\"wp-block-uagb-image__figure\"><a class=\"\" href=\"https:\/\/led.amasly.com\/ms\/\" target=\"\" rel=\"noopener\"><img decoding=\"async\" srcset=\"https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/12\/Amasly-Explosion-proof-light-1024x576.png ,https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/12\/Amasly-Explosion-proof-light.png 780w, https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/12\/Amasly-Explosion-proof-light.png 360w\" sizes=\"auto, (max-width: 480px) 150px\" src=\"https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/12\/Amasly-Explosion-proof-light-1024x576.png\" alt=\"\" class=\"uag-image-1568\" width=\"1080\" height=\"607\" title=\"Lampu kalis letupan Amasly\" loading=\"lazy\" role=\"img\"><\/a><\/figure><\/div>\n\n\n\n<p class=\"has-medium-font-size\">I. Penyelenggaraan Peralatan Elektrik Kalis Letupan Apabila didapati semasa penyelenggaraan bahawa prestasi kalis letupan peralatan elektrik kalis letupan telah merosot atau gagal disebabkan kerosakan akibat daya luaran, kakisan atmosfera, kakisan kimia, keausan mekanikal, penuaan semula jadi, dan sebab-sebab lain, penyelenggaraan adalah perlu. Penyelenggaraan peralatan elektrik kalis letupan hendaklah dijalankan mengikut peraturan yang berkaitan. Jika gred prestasi kalis letupan asal tidak dapat dipulihkan selepas penyelenggaraan, ia boleh ditangani berdasarkan prestasi teknikal sebenar mengikut prinsip-prinsip berikut: <\/p>\n\n\n\n<p class=\"has-medium-font-size\">1. Gunakan pada gred kalis letupan yang lebih rendah. <\/p>\n\n\n\n<p class=\"has-medium-font-size\">2. Menukar kepada peralatan elektrik bukan kalis letupan untuk kegunaan. <\/p>\n\n\n\n<p class=\"has-medium-font-size\">II. Kegagalan Prestasi Kalis Letupan Peralatan Elektrik Kalis LetupanApabila dikenal pasti semasa penyelenggaraan bahawa struktur dan parameter peralatan elektrik kalis letupan telah berubah, dan ia tidak mematuhi jenis dan reka bentuk kalis letupan asal serta tidak dapat dibaiki, ia dianggap sebagai kegagalan dan hendaklah segera dilucutkan tugas dan diganti. Sebagai contoh: <\/p>\n\n\n\n<p class=\"has-medium-font-size\">1. Bekas peralatan elektrik kalis api cacat teruk dan tidak dapat dibaiki. <\/p>\n\n\n\n<p class=\"has-medium-font-size\">2. Permukaan kalis api rosak teruk dan tidak dapat dibaiki. <\/p>\n\n\n\n<p class=\"has-medium-font-size\">3. Jurang kalis api melebihi piawaian dan tidak boleh dibaiki. <\/p>\n\n\n\n<p class=\"has-medium-font-size\">4. Sarung peralatan elektrik kalis letupan retak dan tidak memenuhi keperluan jenis kalis letupan asal.<\/p>\n\n\n\n<p><\/p>","protected":false},"excerpt":{"rendered":"<p>The usage environment of explosion-proof electrical equipment is typically highly corrosive and harsh. Regular maintenance of explosion-proof electrical equipment is a crucial task to guarantee its sustained and effective explosion-proof performance. I. Maintenance of Explosion-proof Electrical Equipment When it is discovered during maintenance that the explosion-proof performance of explosion-proof electrical equipment has deteriorated or failed [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":1568,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_uag_custom_page_level_css":"","site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"disabled","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[8],"tags":[],"class_list":["post-1567","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-explosion-proof-equipment"],"uagb_featured_image_src":{"full":["https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/12\/Amasly-Explosion-proof-light.png",1080,607,false],"thumbnail":["https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/12\/Amasly-Explosion-proof-light-150x150.png",150,150,true],"medium":["https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/12\/Amasly-Explosion-proof-light-300x169.png",300,169,true],"medium_large":["https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/12\/Amasly-Explosion-proof-light-768x432.png",768,432,true],"large":["https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/12\/Amasly-Explosion-proof-light-1024x576.png",1024,576,true],"1536x1536":["https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/12\/Amasly-Explosion-proof-light.png",1080,607,false],"2048x2048":["https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/12\/Amasly-Explosion-proof-light.png",1080,607,false],"trp-custom-language-flag":["https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/12\/Amasly-Explosion-proof-light.png",18,10,false]},"uagb_author_info":{"display_name":"Joe","author_link":"https:\/\/led.amasly.com\/ms\/author\/jacklin\/"},"uagb_comment_info":0,"uagb_excerpt":"The usage environment of explosion-proof electrical equipment is typically highly corrosive and harsh. Regular maintenance of explosion-proof electrical equipment is a crucial task to guarantee its sustained and effective explosion-proof performance. I. Maintenance of Explosion-proof Electrical Equipment When it is discovered during maintenance that the explosion-proof performance of explosion-proof electrical equipment has deteriorated or failed&hellip;","_links":{"self":[{"href":"https:\/\/led.amasly.com\/ms\/wp-json\/wp\/v2\/posts\/1567","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/led.amasly.com\/ms\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/led.amasly.com\/ms\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/led.amasly.com\/ms\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/led.amasly.com\/ms\/wp-json\/wp\/v2\/comments?post=1567"}],"version-history":[{"count":1,"href":"https:\/\/led.amasly.com\/ms\/wp-json\/wp\/v2\/posts\/1567\/revisions"}],"predecessor-version":[{"id":1569,"href":"https:\/\/led.amasly.com\/ms\/wp-json\/wp\/v2\/posts\/1567\/revisions\/1569"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/led.amasly.com\/ms\/wp-json\/wp\/v2\/media\/1568"}],"wp:attachment":[{"href":"https:\/\/led.amasly.com\/ms\/wp-json\/wp\/v2\/media?parent=1567"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/led.amasly.com\/ms\/wp-json\/wp\/v2\/categories?post=1567"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/led.amasly.com\/ms\/wp-json\/wp\/v2\/tags?post=1567"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}