防爆機器

Classification, structure and installation of explosion proof flexible pipes and how to judge whether to install them or not

Explosion-proof flexible pipe with flame retardant, corrosion resistance, aging resistance and other performance advantages, often used in large quantities in petrochemical and other explosive hazardous places, it can not only effectively prevent the occurrence of explosions and fires, but also protect the safety of equipment and personnel. I. Classification of explosion-proof flexible tube 1. According to the explosion-proof type, the explosion-proof flexible pipe is usually divided into explosion-proof type and safety-enhancing type, respectively, with explosion-proof equipment and safety-enhancing equipment, as a flexible connection for conduit wiring. Field installation should be matched with the explosion-proof electrical equipment explosion-proof type. 2. According to the material, performance and use of the scene can be […]

Classification, structure and installation of explosion proof flexible pipes and how to judge whether to install them or not 続きを読む »

What is the difference between explosion proof cables and conventional cables?

I. Application of explosion-proof cables: Explosion-proof cables are widely used in electrical equipment and systems in hazardous environments such as petroleum, chemical, coal mine and ship to ensure safety and reliability in the workplace. They are also used in the power supply lines and control lines of fire pumps, sprinkler pumps, fire elevators, power supply and control lines of fire shutter doors, electric fire doors, smoke exhaust system fans, smoke exhaust valves, fire dampers, security CCTV lines in high-rise buildings and airports, subways and other important facilities, centralized power supply of emergency lighting lines, control and protection of power supply lines and so on. Explosion-proof cables differ significantly from conventional

What is the difference between explosion proof cables and conventional cables? 続きを読む »

Why is it necessary to prevent dust explosion? and Five measures to prevent dust explosions

Why is it necessary to prevent dust explosion? and Five measures to prevent dust explosions According to relevant statistics, from 1900 to 1956, a total of more than 1,000 dust explosion accidents in the United States, Japan from 1952 to 1979, more than 200 such accidents. In China, in 1942, the Benxi coal mine coal dust explosion accident, 1987 Harbin flax factory dust explosion accident, 2010 Qinhuangdao Lixi Hua starch company “2-24” major dust explosion accident, 2014 Suzhou Kunshan Zhongrong “8-2” special major explosion accident, etc., the loss of money. In 2014, Suzhou Kunshan Zhongrong Company “8-2” special major explosion accident, etc., the losses and lessons are very heavy. Therefore,

Why is it necessary to prevent dust explosion? and Five measures to prevent dust explosions 続きを読む »

Explosion proof lighting switch introduction

Knowledge about explosion-proof Lighting switches explained What is an explosion proof lighting switch? An explosion-proof switch is an electrical control device designed for flammable and explosive environments, with the core function of achieving safe and reliable electrical control in extremely hazardous locations. The device is designed to follow strict international standards (e.g. IEC 60079) to ensure that any form of ignition source is prevented from arising in potentially explosive gas or dust environments, thus avoiding the initiation of a fire or explosion. The housings of explosion-proof switches are usually made of high-strength metal materials that are specially sealed to withstand harsh operating conditions. The internal circuit design utilizes isolation technology

Explosion proof lighting switch introduction 続きを読む »

Electrical explosion proof and ventilation requirements for gas boiler rooms

1 gas boiler room explosion-proof design Oil, gas boiler room boiler room gas regulator room, fuel pump room, pulverized coal preparation room, coal crusher room and coal transport corridor with explosion hazardous areas such as the classification, should be consistent with the current Chinese and European Union standards, “Explosion Hazardous Environment Electrical Installation Design Code” GB50058 of the relevant provisions; gas boiler room boiler room gas regulator room belongs to the explosion hazardous areas. “Gas boiler room safety exit emergency evacuation indicator” close to the explosion hazardous area above or above the explosion shall be designed for explosion-proof type. Meet one of the following conditions, can be categorized as non-explosion

Electrical explosion proof and ventilation requirements for gas boiler rooms 続きを読む »

Explosion-proof lamps and explosion-proof equipment Tools for explosive environments

Personnel responsible for operating equipment and processes in explosive environments should provide all personnel working on site with information and materials on the safe use of hand tools. The following two different types of tools should be distinguished: (1) Tools that can only cause a single spark when in use (such as screwdrivers, wrenches, impact screwdrivers); (2) Tools that produce a cluster of sparks during cutting or grinding processes. In Zone 0 and Zone 20, tools that can cause sparks are not allowed to be used. In Zone 1 and Zone 2, steel tools are only permitted when they meet the requirements of item (1). If it can be ensured

Explosion-proof lamps and explosion-proof equipment Tools for explosive environments 続きを読む »

explosion-proof lamps:Special requirements for ambient temperature of flameproof electrical equipment

Ambient temperature refers to the temperature of the air or other medium surrounding the equipment or component. Under normal circumstances, the ambient temperature for equipment operation should be -20 to 40 ℃. In such cases, no additional ambient temperature marking is required. However, when the equipment is expected to be used in an environment outside this temperature range, it is considered a special situation. The marking should include the symbol Ta or Tamb along with the upper and lower limits of the ambient temperature. If this is not feasible, the symbol “X” should indicate the special operating conditions including the upper and lower limits of the ambient temperature. This means

explosion-proof lamps:Special requirements for ambient temperature of flameproof electrical equipment 続きを読む »

Amasly: Those matters that cannot be ignored in the warehouse management of professional explosion-proof lighting companies

In the operation of enterprises, warehouse management plays a very important role and is the cornerstone of ensuring the continuous stability of product quality. Once problems occur, it will directly cause economic losses and even bring adverse effects to the brand. Now let’s talk about those things in warehouse management that cannot be ignored. The warehouse should have appropriate warehouse management systems and be staffed with professional personnel. Stored items should be classified and placed on shelves. For small parts, storage boxes can be added to the shelves. Labels should be used to identify the model and quantity of each item for easy management and query. Regular inspections of stored

Amasly: Those matters that cannot be ignored in the warehouse management of professional explosion-proof lighting companies 続きを読む »

Requirements for gaskets and seals in equipment protected by dust ignition-proof enclosures “t” for explosion-proof lamps

It is well known that the protective performance of the equipment enclosure protected by the dust-proof ignition-proof enclosure “t” is a key point that product design focuses on. Therefore, the structural rationality of the gaskets and seals that play a protective role is particularly important. I. Structural Requirements In the mating surfaces, compressed gaskets can be used to ensure the effectiveness of the enclosure seal. All gaskets and seals should be of an integral continuous structure, that is, annular and uninterrupted. The structure of the enclosure should ensure the correct position of the gaskets. If the protection degree of the enclosure depends on the gasket at the enclosure joint and

Requirements for gaskets and seals in equipment protected by dust ignition-proof enclosures “t” for explosion-proof lamps 続きを読む »

Introduction to the Pouring Sealed Explosion-proof Type of Explosion-proof Lamps

The encapsulated type involves completely enclosing the components that may generate sparks or heat capable of igniting explosive mixtures within a compound or a non-metallic casing with adhesive bonding, ensuring that they cannot ignite dust layers or explosive environments under operating or installation conditions. The above is the definition of potting type. In simple terms, it means to enclose the possible ignition sources so that they do not have the ability to ignite under normal operation and fault conditions. Common enclosure processes include die-casting and casting. For equipment protected by potting type “m”, the compound, potting structure, equipment temperature, testing and marking need to be considered. 1. Consider the manufacturer

Introduction to the Pouring Sealed Explosion-proof Type of Explosion-proof Lamps 続きを読む »

初回購入時に30%を割引

X
jaJA