{"id":1567,"date":"2024-12-26T22:55:25","date_gmt":"2024-12-26T14:55:25","guid":{"rendered":"https:\/\/led.amasly.com\/?p=1567"},"modified":"2024-12-28T14:53:07","modified_gmt":"2024-12-28T06:53:07","slug":"the-treatment-approaches-for-the-failure-of-explosion-proof-performance-of-explosion-proof-electrical-equipment","status":"publish","type":"post","link":"https:\/\/led.amasly.com\/it\/explosion-proof-equipment\/the-treatment-approaches-for-the-failure-of-explosion-proof-performance-of-explosion-proof-electrical-equipment\/","title":{"rendered":"Approcci di trattamento per il fallimento delle prestazioni antideflagranti delle apparecchiature elettriche antideflagranti"},"content":{"rendered":"<p class=\"has-medium-font-size\">L'ambiente di utilizzo delle apparecchiature elettriche antideflagranti \u00e8 in genere altamente corrosivo e difficile. La manutenzione regolare delle apparecchiature elettriche antideflagranti \u00e8 un compito cruciale per garantire prestazioni antideflagranti durature ed efficaci. <\/p>\n\n\n\n<div class=\"wp-block-uagb-image uagb-block-d748ffbc wp-block-uagb-image--layout-default wp-block-uagb-image--effect-static wp-block-uagb-image--align-none\"><figure class=\"wp-block-uagb-image__figure\"><a class=\"\" href=\"https:\/\/led.amasly.com\/it\/\" target=\"\" rel=\"noopener\"><img decoding=\"async\" srcset=\"https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/12\/Amasly-Explosion-proof-light-1024x576.png ,https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/12\/Amasly-Explosion-proof-light.png 780w, https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/12\/Amasly-Explosion-proof-light.png 360w\" sizes=\"auto, (max-width: 480px) 150px\" src=\"https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/12\/Amasly-Explosion-proof-light-1024x576.png\" alt=\"\" class=\"uag-image-1568\" width=\"1080\" height=\"607\" title=\"Amasly Luce antideflagrante\" loading=\"lazy\" role=\"img\"><\/a><\/figure><\/div>\n\n\n\n<p class=\"has-medium-font-size\">I. Manutenzione delle apparecchiature elettriche antideflagranti Quando durante la manutenzione si scopre che le prestazioni antideflagranti delle apparecchiature elettriche antideflagranti si sono deteriorate o sono venute meno a causa di danni provocati da forze esterne, corrosione atmosferica, corrosione chimica, usura meccanica, invecchiamento naturale e altri motivi, \u00e8 necessario procedere alla manutenzione. La manutenzione delle apparecchiature elettriche antideflagranti deve essere effettuata in conformit\u00e0 alle normative vigenti. Se il grado di prestazione antideflagrante originale non pu\u00f2 essere ripristinato dopo la manutenzione, \u00e8 possibile gestirlo in base alle prestazioni tecniche effettive seguendo i principi riportati di seguito: <\/p>\n\n\n\n<p class=\"has-medium-font-size\">1. Utilizzare un grado di protezione antideflagrante inferiore. <\/p>\n\n\n\n<p class=\"has-medium-font-size\">2. Convertire in apparecchiature elettriche non antideflagranti per l'utilizzo. <\/p>\n\n\n\n<p class=\"has-medium-font-size\">II. Quando durante la manutenzione viene rilevato che la struttura e i parametri delle apparecchiature elettriche antideflagranti sono cambiati e non sono conformi al tipo e al progetto antideflagrante originale e non possono essere riparati, si tratta di un guasto che deve essere prontamente disattivato e sostituito. Ad esempio: <\/p>\n\n\n\n<p class=\"has-medium-font-size\">1. L'involucro dell'apparecchiatura elettrica antideflagrante \u00e8 gravemente deformato e non pu\u00f2 essere riparato. <\/p>\n\n\n\n<p class=\"has-medium-font-size\">2. La superficie ignifuga \u00e8 gravemente danneggiata e non pu\u00f2 essere riparata. <\/p>\n\n\n\n<p class=\"has-medium-font-size\">3. La fessura antideflagrante supera lo standard e non pu\u00f2 essere riparata. <\/p>\n\n\n\n<p class=\"has-medium-font-size\">4. L'involucro delle apparecchiature elettriche antideflagranti \u00e8 incrinato e non soddisfa i requisiti del tipo originale antideflagrante.<\/p>\n\n\n\n<p><\/p>","protected":false},"excerpt":{"rendered":"<p>The usage environment of explosion-proof electrical equipment is typically highly corrosive and harsh. Regular maintenance of explosion-proof electrical equipment is a crucial task to guarantee its sustained and effective explosion-proof performance. I. Maintenance of Explosion-proof Electrical Equipment When it is discovered during maintenance that the explosion-proof performance of explosion-proof electrical equipment has deteriorated or failed [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":1568,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_uag_custom_page_level_css":"","site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"disabled","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[8],"tags":[],"class_list":["post-1567","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-explosion-proof-equipment"],"uagb_featured_image_src":{"full":["https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/12\/Amasly-Explosion-proof-light.png",1080,607,false],"thumbnail":["https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/12\/Amasly-Explosion-proof-light-150x150.png",150,150,true],"medium":["https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/12\/Amasly-Explosion-proof-light-300x169.png",300,169,true],"medium_large":["https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/12\/Amasly-Explosion-proof-light-768x432.png",768,432,true],"large":["https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/12\/Amasly-Explosion-proof-light-1024x576.png",1024,576,true],"1536x1536":["https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/12\/Amasly-Explosion-proof-light.png",1080,607,false],"2048x2048":["https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/12\/Amasly-Explosion-proof-light.png",1080,607,false],"trp-custom-language-flag":["https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/12\/Amasly-Explosion-proof-light.png",18,10,false]},"uagb_author_info":{"display_name":"Joe","author_link":"https:\/\/led.amasly.com\/it\/author\/jacklin\/"},"uagb_comment_info":0,"uagb_excerpt":"The usage environment of explosion-proof electrical equipment is typically highly corrosive and harsh. Regular maintenance of explosion-proof electrical equipment is a crucial task to guarantee its sustained and effective explosion-proof performance. I. Maintenance of Explosion-proof Electrical Equipment When it is discovered during maintenance that the explosion-proof performance of explosion-proof electrical equipment has deteriorated or failed&hellip;","_links":{"self":[{"href":"https:\/\/led.amasly.com\/it\/wp-json\/wp\/v2\/posts\/1567","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/led.amasly.com\/it\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/led.amasly.com\/it\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/led.amasly.com\/it\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/led.amasly.com\/it\/wp-json\/wp\/v2\/comments?post=1567"}],"version-history":[{"count":1,"href":"https:\/\/led.amasly.com\/it\/wp-json\/wp\/v2\/posts\/1567\/revisions"}],"predecessor-version":[{"id":1569,"href":"https:\/\/led.amasly.com\/it\/wp-json\/wp\/v2\/posts\/1567\/revisions\/1569"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/led.amasly.com\/it\/wp-json\/wp\/v2\/media\/1568"}],"wp:attachment":[{"href":"https:\/\/led.amasly.com\/it\/wp-json\/wp\/v2\/media?parent=1567"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/led.amasly.com\/it\/wp-json\/wp\/v2\/categories?post=1567"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/led.amasly.com\/it\/wp-json\/wp\/v2\/tags?post=1567"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}