{"id":2565,"date":"2025-03-19T20:41:54","date_gmt":"2025-03-19T12:41:54","guid":{"rendered":"https:\/\/led.amasly.com\/?page_id=2565"},"modified":"2026-01-30T20:56:27","modified_gmt":"2026-01-30T12:56:27","slug":"explosion-proof-led-lights-in-the-boiler-room-lighting-applications","status":"publish","type":"page","link":"https:\/\/led.amasly.com\/it\/knowledge\/explosion-proof-products-knowledge\/explosion-proof-led-lights-in-the-boiler-room-lighting-applications\/","title":{"rendered":"Luci a led antideflagranti nelle applicazioni di illuminazione del locale caldaia"},"content":{"rendered":"\n<div class=\"wp-block-uagb-container uagb-block-27bae773 alignfull uagb-is-root-container\"><div class=\"uagb-container-inner-blocks-wrap\"><\/div><\/div>\n\n\n\n<h1 class=\"wp-block-heading has-text-align-center\"><strong>E<\/strong><strong>xplosion proof led lights<\/strong><strong>&nbsp;<\/strong><strong>in the boiler room lighting applications<\/strong><\/h1>\n\n\n\n<div class=\"wp-block-uagb-image uagb-block-e2f99b2d wp-block-uagb-image--layout-default wp-block-uagb-image--effect-static wp-block-uagb-image--align-none\"><figure class=\"wp-block-uagb-image__figure\"><img decoding=\"async\" srcset=\"https:\/\/led.amasly.com\/wp-content\/uploads\/2025\/12\/BAT86-LED-Explosion-proof-lights.jpg ,https:\/\/led.amasly.com\/wp-content\/uploads\/2025\/12\/BAT86-LED-Explosion-proof-lights.jpg 780w, https:\/\/led.amasly.com\/wp-content\/uploads\/2025\/12\/BAT86-LED-Explosion-proof-lights.jpg 360w\" sizes=\"auto, (max-width: 480px) 150px\" src=\"https:\/\/led.amasly.com\/wp-content\/uploads\/2025\/12\/BAT86-LED-Explosion-proof-lights.jpg\" alt=\"Explosion proof led light fixtures, Explosion proof led luminaries, Explosion proof led lights\" class=\"uag-image-4398\" width=\"1004\" height=\"308\" title=\"BAT86 LED Explosion proof lights\" loading=\"lazy\" role=\"img\"\/><\/figure><\/div>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>1. Boiler room lighting special challenges and explosion proof led lights\u200b core value<\/strong><\/h2>\n\n\n\n<p>Boiler room as a power plant, chemical plants and other industrial facilities in the core area, there are gas leakage [such as natural gas], high-temperature steam [up to 500 \u2103] and dust accumulation and other multiple risks.<\/p>\n\n\n\n<p>According to GB50058-2014 \u201cDesign Code for Electrical Installations in Explosive Hazardous Environments\u201d, the gas boiler area is defined as an IIA\/IIB explosive gas environment Zone 1, which must use Ex d IIB T4 and above explosion-proof lighting equipment.<\/p>\n\n\n\n<p>Traditional lighting fixtures in such environments are prone to explosions caused by electric sparks, while the professional design of explosion proof led lights\u200bapproved by the multi-protection structure, the surface temperature can be controlled in the T6 group [\u2264 80 \u00b0 C] within the safety range, into the boiler room safe operation of the necessary equipment.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>Boiler room lighting three core requirements<\/strong><strong><\/strong><\/h3>\n\n\n\n<p>Intrinsic explosion-proof performance: need to block the lamps and lanterns internal circuit sparks and external combustible gases [such as methane, hydrogen] contact<\/p>\n\n\n\n<p>High-temperature resistance: the lamps need to work in a stable ambient temperature of 50-150 \u2103, the heat dissipation structure needs to meet the requirements of the LED chip temperature rise control.<\/p>\n\n\n\n<p>Chemical corrosion protection: to deal with steam condensate, hydrogen sulfide and other corrosive media, the shell needs to be die-cast aluminum + nano-spray process, anti-corrosion grade of WF2<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>2 <\/strong><strong>explosion proof led lights<\/strong><strong>&nbsp;<\/strong><strong>technical characteristics and boiler room scenarios adaptable program<\/strong><strong><\/strong><\/h2>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>2.1 Explosion-proof structure innovation design<\/strong><strong><\/strong><\/h3>\n\n\n\n<p>For the boiler room environment, explosion proof led lights\u200busing explosion-proof [Ex d] and increased safety [Ex e] composite protection:<\/p>\n\n\n\n<p>Multiple explosion-proof barriers: die-casting aluminum shell thickness \u2265 5mm, tempered glass cover can withstand more than 7J impact, filled with heat-conductive silica gel to implement high-speed heat dissipation.<\/p>\n\n\n\n<p>Intelligent temperature control system: built-in temperature sensor real-time monitoring of the state of the lamps and lanterns, overheating automatically reduce power operation [such as a 150W explosion proof led lights\u200b&nbsp;case shows that the surface temperature can be controlled below 65 \u2103].<\/p>\n\n\n\n<p>Seal protection upgrade: the introduction of dual-channel labyrinth sealing structure, the protection level of IP66\/IP68, effectively blocking the intrusion of water vapor and dust.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>2.2 Scientific matching of power and light efficiency<\/strong><strong><\/strong><\/h3>\n\n\n\n<p>According to the division of boiler room area to choose the appropriate program:<\/p>\n\n\n\n<p>Gas boiler body area: Recommended power 150-300W, installation density of 2 \/ 10 square meters, illumination guidelines \u2265 500Lux, explosion-proof grade requirements Ex d IIB T4 Gb<\/p>\n\n\n\n<p>Steam pipeline inspection channel: recommended power 70-100W, installation density of 3 \/ 10 square meters, illumination guidelines \u2265 300Lux, explosion-proof grade requirements Ex e II T6 Gb<\/p>\n\n\n\n<p>Control room and power distribution area: recommended power 40-60W, installation density of 4 lamps \/ 10 square meters, illumination guidelines \u2265 200Lux, explosion-proof grade requirements Ex nR II T3 Gb<\/p>\n\n\n\n<p>A gas power plant renovation project, for example, the use of 24 sets of 150W explosion-proof LED floodlights, illuminance uniformity from 0.68 to 0.92, to meet the requirements of <a href=\"http:\/\/www.iecex-certs.com\/\" rel=\"nofollow noopener\" target=\"_blank\">EN 12464-1 <\/a>guidelines.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>3. boiler room <\/strong><strong>explosion proof led lights<\/strong><strong>&nbsp;<\/strong><strong>selection five dimensions<\/strong><strong><\/strong><\/h2>\n\n\n\n<p>Certification compliance: CNEx\/PCEC must be issued Ex d IIB T4 certification, and labeled with the full explosion-proof mark [such as Ex d e mb IIC T6 Gb].<\/p>\n\n\n\n<p>Optical system improvements: Wide beam [120\u00b0] lamps for inspection channels, narrow beam [60\u00b0] for precise illumination of instrument panels.<\/p>\n\n\n\n<p>Thermal management design: die-cast aluminum housing with heat sink fins, heat sink area \u2265 800cm\u00b2\/W [ensure chip junction temperature &lt;85\u2103].<\/p>\n\n\n\n<p>Emergency function integration: equipped with 180 minutes of backup power, automatically switch to emergency mode in case of power failure [brightness \u2265 50% of normal mode].<\/p>\n\n\n\n<p>Convenience of maintenance: Quick-open structure design makes the operation of changing lamps &lt;3 minutes, with the help of power-carrying maintenance function.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>4. Explosion proof led lights<\/strong> <strong>Industry application cases and benefit analysis<\/strong><\/h2>\n\n\n\n<p>A biomass power plant boiler room renovation project<\/p>\n\n\n\n<p>Original system problems:<\/p>\n\n\n\n<p>The surface temperature of 400W high-pressure sodium lamp reaches 130\u2103, which has caused two steam pipe flash fire accidents with an annual maintenance cost of 120,000 RMB [including explosion-proof glass replacement and circuit overhaul].<\/p>\n\n\n\n<p>Remodeling program:<\/p>\n\n\n\n<p>Installation of 18 sets of 200W modular explosion proof led lights\u200b[Ex d IIB T6\/IP66] integrated microwave induction and DALI dimming system<\/p>\n\n\n\n<p>Comparison of results:<\/p>\n\n\n\n<p>Annual electricity cost: 98,000 RMB before retrofitting, 32,000 RMB after retrofitting, up 67.3%.<\/p>\n\n\n\n<p>Failure rate: 28 times\/year before the retrofit, 1 time\/year after the retrofit, an increase of 96.4%.<\/p>\n\n\n\n<p>Inspection efficiency: 78% before retrofitting, 95% after retrofitting, up 21.8%.<\/p>\n\n\n\n<p>The payback period was only 1.5 years, and ISO50001 energy management system certification was approved.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>5. Explosion proof led lights<\/strong> <strong>Technology development momentum outlook<\/strong><\/h2>\n\n\n\n<p>Material innovation: Graphene composite thermal coating reduces luminaire weight by 40% and improves thermal conductivity by 300%.<\/p>\n\n\n\n<p>Digital Twin: 3D modeling is approved to preview light spot distribution, solving the problem of blind spot inspection caused by the shadow of the boiler body.<\/p>\n\n\n\n<p class=\"has-text-align-left\">Energy autonomy: PV+storage off-grid explosion-proof lighting system has been piloted in outdoor boilers to implement zero-carbon lighting<\/p>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-c7d898dd alignfull uagb-is-root-container\"><div class=\"uagb-container-inner-blocks-wrap\"><\/div><\/div>\n\n\n\n<h2 class=\"wp-block-heading\">Related Products<\/h2>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-66e4defc alignfull uagb-is-root-container\"><div class=\"uagb-container-inner-blocks-wrap\">\n<div class=\"wp-block-uagb-container uagb-block-a42945f9\">\n<div class=\"wp-block-uagb-image uagb-block-7296296b wp-block-uagb-image--layout-default wp-block-uagb-image--effect-static wp-block-uagb-image--align-none\"><figure class=\"wp-block-uagb-image__figure\"><a class=\"\" href=\"https:\/\/led.amasly.com\/products\/\" target=\"\" rel=\"noopener\"><img decoding=\"async\" srcset=\"https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/09\/Explosion-proof-high-bay-lights.png ,https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/09\/Explosion-proof-high-bay-lights.png 780w, https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/09\/Explosion-proof-high-bay-lights.png 360w\" sizes=\"auto, (max-width: 480px) 150px\" src=\"https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/09\/Explosion-proof-high-bay-lights.png\" alt=\"\" class=\"uag-image-1495\" width=\"300\" height=\"300\" title=\"Explosion proof high bay lights\" loading=\"lazy\" role=\"img\"><\/a><\/figure><\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-4d3efde5\">\n<div class=\"wp-block-uagb-image uagb-block-c9e90797 wp-block-uagb-image--layout-default wp-block-uagb-image--effect-static wp-block-uagb-image--align-none\"><figure class=\"wp-block-uagb-image__figure\"><a class=\"\" href=\"https:\/\/led.amasly.com\/products\/\" target=\"\" rel=\"noopener\"><img decoding=\"async\" srcset=\"https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/07\/LED-tri-proof-lights2.png ,https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/07\/LED-tri-proof-lights2.png 780w, https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/07\/LED-tri-proof-lights2.png 360w\" sizes=\"auto, (max-width: 480px) 150px\" src=\"https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/07\/LED-tri-proof-lights2.png\" alt=\"\" class=\"uag-image-1132\" width=\"300\" height=\"300\" title=\"LED-tri-proof-lights2\" loading=\"lazy\" role=\"img\"><\/a><\/figure><\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-11c2578b\">\n<div class=\"wp-block-uagb-image uagb-block-6e8883aa wp-block-uagb-image--layout-default wp-block-uagb-image--effect-static wp-block-uagb-image--align-none\"><figure class=\"wp-block-uagb-image__figure\"><a class=\"\" href=\"https:\/\/led.amasly.com\/products\/\" target=\"\" rel=\"noopener\"><img decoding=\"async\" srcset=\"https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/09\/LED-Explosion-Proof-Gas-Station-Light.png ,https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/09\/LED-Explosion-Proof-Gas-Station-Light.png 780w, https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/09\/LED-Explosion-Proof-Gas-Station-Light.png 360w\" sizes=\"auto, (max-width: 480px) 150px\" src=\"https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/09\/LED-Explosion-Proof-Gas-Station-Light.png\" alt=\"\" class=\"uag-image-1501\" width=\"300\" height=\"300\" title=\"LED Explosion Proof Gas Station Light\" loading=\"lazy\" role=\"img\"><\/a><\/figure><\/div>\n<\/div>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-548945b5 alignfull uagb-is-root-container\"><div class=\"uagb-container-inner-blocks-wrap\">\n<div class=\"wp-block-uagb-container uagb-block-967755d5\">\n<h4 class=\"wp-block-heading has-text-align-center\"><a href=\"https:\/\/led.amasly.com\/products\/\">LED Explosion Proof Lights<\/a><\/h4>\n<\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-9bc52fc2\">\n<h4 class=\"wp-block-heading has-text-align-center\"><a href=\"https:\/\/led.amasly.com\/products\/\">LED Tri-Proof Lights<\/a><\/h4>\n<\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-8ffa0a23\">\n<h4 class=\"wp-block-heading has-text-align-center\"><a href=\"https:\/\/led.amasly.com\/products\/\">Explosion Proof Gas Station Lights<\/a><\/h4>\n<\/div>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-29499fe0 alignfull uagb-is-root-container\"><div class=\"uagb-container-inner-blocks-wrap\">\n<div class=\"wp-block-uagb-container uagb-block-777ee1c7\">\n<div class=\"wp-block-uagb-image uagb-block-2e9a1851 wp-block-uagb-image--layout-default wp-block-uagb-image--effect-static wp-block-uagb-image--align-none\"><figure class=\"wp-block-uagb-image__figure\"><a class=\"\" href=\"https:\/\/led.amasly.com\/products\/\" target=\"\" rel=\"noopener\"><img decoding=\"async\" srcset=\"https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/10\/50W-100W-150W-200W-300W-LED-Flood-Light.jpg ,https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/10\/50W-100W-150W-200W-300W-LED-Flood-Light.jpg 780w, https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/10\/50W-100W-150W-200W-300W-LED-Flood-Light.jpg 360w\" sizes=\"auto, (max-width: 480px) 150px\" src=\"https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/10\/50W-100W-150W-200W-300W-LED-Flood-Light.jpg\" alt=\"\" class=\"uag-image-1526\" width=\"300\" height=\"300\" title=\"50W 100W 150W 200W 300W LED Flood Light\" loading=\"lazy\" role=\"img\"><\/a><\/figure><\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-af8c8683\">\n<div class=\"wp-block-uagb-image uagb-block-67947854 wp-block-uagb-image--layout-default wp-block-uagb-image--effect-static wp-block-uagb-image--align-none\"><figure class=\"wp-block-uagb-image__figure\"><a class=\"\" href=\"https:\/\/led.amasly.com\/products\/\" target=\"\" rel=\"noopener\"><img decoding=\"async\" srcset=\"https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/07\/led-tri-proof-light.png ,https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/07\/led-tri-proof-light.png 780w, https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/07\/led-tri-proof-light.png 360w\" sizes=\"auto, (max-width: 480px) 150px\" src=\"https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/07\/led-tri-proof-light.png\" alt=\"\" class=\"uag-image-1130\" width=\"300\" height=\"300\" title=\"led-tri-proof-light\" loading=\"lazy\" role=\"img\"><\/a><\/figure><\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-0fdfdd58\">\n<div class=\"wp-block-uagb-image uagb-block-1187d32d wp-block-uagb-image--layout-default wp-block-uagb-image--effect-static wp-block-uagb-image--align-none\"><figure class=\"wp-block-uagb-image__figure\"><a class=\"\" href=\"https:\/\/led.amasly.com\/products\/\" target=\"\" rel=\"noopener\"><img decoding=\"async\" srcset=\"https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/07\/LED-street-light.jpg ,https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/07\/LED-street-light.jpg 780w, https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/07\/LED-street-light.jpg 360w\" sizes=\"auto, (max-width: 480px) 150px\" src=\"https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/07\/LED-street-light.jpg\" alt=\"\" class=\"uag-image-1145\" width=\"300\" height=\"300\" title=\"LED-street-light\" loading=\"lazy\" role=\"img\"><\/a><\/figure><\/div>\n<\/div>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-6a60882c alignfull uagb-is-root-container\"><div class=\"uagb-container-inner-blocks-wrap\">\n<div class=\"wp-block-uagb-container uagb-block-f1e91a35\">\n<h4 class=\"wp-block-heading has-text-align-center\"><a href=\"https:\/\/led.amasly.com\/products\/\">LED Flood Lights<\/a><\/h4>\n<\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-165bfa58\">\n<h4 class=\"wp-block-heading has-text-align-center\"><a href=\"https:\/\/led.amasly.com\/products\/\">LED Tri-Proof Tube Lights<\/a><\/h4>\n<\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-f6096e3b\">\n<h4 class=\"wp-block-heading has-text-align-center\"><a href=\"https:\/\/led.amasly.com\/products\/\">LED Street Lights<\/a><\/h4>\n<\/div>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-99c0e0a5 alignfull uagb-is-root-container\"><div class=\"uagb-container-inner-blocks-wrap\"><\/div><\/div>\n\n\n\n<p><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Explosion proof led lights&nbsp;in the boiler room lighting applications 1. Boiler room lighting special challenges and explosion proof led lights\u200b core value Boiler room as a power plant, chemical plants and other industrial facilities in the core area, there are gas leakage [such as natural gas], high-temperature steam [up to 500 \u2103] and dust accumulation [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":2374,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_uag_custom_page_level_css":"","site-sidebar-layout":"no-sidebar","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"disabled","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"enabled","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"class_list":["post-2565","page","type-page","status-publish","hentry"],"uagb_featured_image_src":{"full":false,"thumbnail":false,"medium":false,"medium_large":false,"large":false,"1536x1536":false,"2048x2048":false,"trp-custom-language-flag":false},"uagb_author_info":{"display_name":"Joe","author_link":"https:\/\/led.amasly.com\/it\/author\/jacklin\/"},"uagb_comment_info":0,"uagb_excerpt":"Explosion proof led lights&nbsp;in the boiler room lighting applications 1. Boiler room lighting special challenges and explosion proof led lights\u200b core value Boiler room as a power plant, chemical plants and other industrial facilities in the core area, there are gas leakage [such as natural gas], high-temperature steam [up to 500 \u2103] and dust accumulation&hellip;","_links":{"self":[{"href":"https:\/\/led.amasly.com\/it\/wp-json\/wp\/v2\/pages\/2565","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/led.amasly.com\/it\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/led.amasly.com\/it\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/led.amasly.com\/it\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/led.amasly.com\/it\/wp-json\/wp\/v2\/comments?post=2565"}],"version-history":[{"count":2,"href":"https:\/\/led.amasly.com\/it\/wp-json\/wp\/v2\/pages\/2565\/revisions"}],"predecessor-version":[{"id":4926,"href":"https:\/\/led.amasly.com\/it\/wp-json\/wp\/v2\/pages\/2565\/revisions\/4926"}],"up":[{"embeddable":true,"href":"https:\/\/led.amasly.com\/it\/wp-json\/wp\/v2\/pages\/2374"}],"wp:attachment":[{"href":"https:\/\/led.amasly.com\/it\/wp-json\/wp\/v2\/media?parent=2565"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}