{"id":2108,"date":"2025-03-01T10:19:05","date_gmt":"2025-03-01T02:19:05","guid":{"rendered":"https:\/\/led.amasly.com\/?p=2108"},"modified":"2025-03-07T21:28:56","modified_gmt":"2025-03-07T13:28:56","slug":"specifications-dinstallation-des-lampes-et-lanternes-antideflagrantes","status":"publish","type":"post","link":"https:\/\/led.amasly.com\/fr\/lumiere\/specifications-dinstallation-des-lampes-et-lanternes-antideflagrantes\/","title":{"rendered":"Sp\u00e9cifications d'installation des lampes et lanternes antid\u00e9flagrantes"},"content":{"rendered":"<h1 class=\"wp-block-heading has-text-align-center\"><strong>Sp\u00e9cifications d'installation des lampes et lanternes antid\u00e9flagrantes<\/strong><strong><\/strong><\/h1>\n\n\n\n<p class=\"wp-block-paragraph\">1. Symboles antid\u00e9flagrants, niveau de protection de la coque et adaptabilit\u00e9 du groupe de temp\u00e9rature : les symboles antid\u00e9flagrants, le niveau de protection de la coque et le groupe de temp\u00e9rature des lampes et des lanternes doivent \u00eatre adapt\u00e9s \u00e0 l'environnement pr\u00e9sentant des risques d'explosion. Lorsque la conception ne l'exige pas, le type de lampes et de lanternes et la structure antid\u00e9flagrante de la s\u00e9lection doivent \u00eatre conformes aux dispositions.<\/p>\n\n\n\n<div class=\"wp-block-uagb-image uagb-block-5670ae3f wp-block-uagb-image--layout-default wp-block-uagb-image--effect-static wp-block-uagb-image--align-none\"><figure class=\"wp-block-uagb-image__figure\"><a class=\"\" href=\"https:\/\/led.amasly.com\/fr\/produits\/\" target=\"\" rel=\"noopener\"><img decoding=\"async\" srcset=\"https:\/\/led.amasly.com\/wp-content\/uploads\/2025\/01\/LED-explosion-proof-linear-lights.png ,https:\/\/led.amasly.com\/wp-content\/uploads\/2025\/01\/LED-explosion-proof-linear-lights.png 780w, https:\/\/led.amasly.com\/wp-content\/uploads\/2025\/01\/LED-explosion-proof-linear-lights.png 360w\" sizes=\"auto, (max-width: 480px) 150px\" src=\"https:\/\/led.amasly.com\/wp-content\/uploads\/2025\/01\/LED-explosion-proof-linear-lights.png\" alt=\"\" class=\"uag-image-1676\" width=\"1004\" height=\"294\" title=\"Luminaires lin\u00e9aires \u00e0 LED antid\u00e9flagrants\" loading=\"lazy\" role=\"img\"><\/a><\/figure><\/div>\n\n\n\n<p class=\"wp-block-paragraph\">2. Utilisation des accessoires de lampes et de lanternes : les accessoires de lampes et de lanternes doivent \u00eatre complets, ne pas utiliser de pi\u00e8ces non antid\u00e9flagrantes \u00e0 la place des accessoires antid\u00e9flagrants, tels que la grille m\u00e9tallique, l'abat-jour, la bo\u00eete de jonction, etc.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">3. S\u00e9lection de l'emplacement d'installation : l'emplacement d'installation des lampes et des lanternes doit \u00eatre \u00e9loign\u00e9 de la source d'\u00e9mission, et les lampes et les lanternes ne doivent pas \u00eatre install\u00e9es sur et sous les orifices de d\u00e9compression et les orifices de d\u00e9charge de diverses conduites. &nbsp; &nbsp;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">4. Exigences relatives \u00e0 l'installation fixe : les lampes et les interrupteurs sont install\u00e9s de mani\u00e8re ferme et fiable, les lampes, les interrupteurs et les fils de la bo\u00eete de jonction n'engagent pas moins de 5 boutons, les fils sont lisses, intacts, sans corrosion, et les fils sont enduits de graisse composite \u00e9lectrique ou de graisse conductrice r\u00e9sistante \u00e0 la rouille.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">5. Int\u00e9grit\u00e9 de la coque : la coque des lampes et des interrupteurs est compl\u00e8te, elle n'est ni endommag\u00e9e, ni enfonc\u00e9e, ni rainur\u00e9e, l'abat-jour n'est pas fissur\u00e9, la grille m\u00e9tallique n'est ni tordue, ni d\u00e9form\u00e9e, et le marquage antid\u00e9flagrant est clair.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">6. \u00c9tat des boulons de fixation et des rondelles d'\u00e9tanch\u00e9it\u00e9 : les boulons de fixation des lampes et des interrupteurs ne sont ni desserr\u00e9s ni corrod\u00e9s, et les rondelles d'\u00e9tanch\u00e9it\u00e9 sont intactes.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">7. conduit et lampes, raccordement \u00e0 la bo\u00eete de jonction : le conduit et les lampes antid\u00e9flagrantes, le raccordement \u00e0 la bo\u00eete de jonction doivent \u00eatre \u00e9tanches, l'\u00e9tanch\u00e9it\u00e9 intacte ; les filetages doivent \u00eatre engag\u00e9s dans le nombre de boutons qui n'est pas inf\u00e9rieur \u00e0 5 boucles, et doivent \u00eatre enduits d'ester composite pour l'\u00e9nergie \u00e9lectrique ou d'ester antirouille conducteur sur les filetages.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">8. R\u00e9glage de l'installation inclin\u00e9e : Lorsque les lampes sont install\u00e9es de biais, les positions relatives des joints et des tubes d'acier doivent \u00eatre ajust\u00e9es pour que la plaque d'ombrage soit directement au-dessus de l'ampoule.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">9. Installation et entretien des mesures de s\u00e9curit\u00e9 : pour l'installation et l'entretien des lampes et des lanternes, il faut d'abord couper l'alimentation \u00e9lectrique ; l'utilisation, la surface des lampes et des lanternes a un certain degr\u00e9 d'\u00e9l\u00e9vation de temp\u00e9rature est un ph\u00e9nom\u00e8ne normal, le centre des parties transparentes de la temp\u00e9rature est plus \u00e9lev\u00e9, il ne faut pas toucher.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">10. Exigences relatives au remplacement des ampoules : lors du remplacement des ampoules, il convient d'utiliser des ampoules de m\u00eame type et de m\u00eame puissance ; si le type ou la puissance des ampoules est modifi\u00e9, le ballast correspondant doit \u00eatre remplac\u00e9 en cons\u00e9quence.<\/p>","protected":false},"excerpt":{"rendered":"<p>Explosion-proof lamps and lanterns installation specification 1. Explosion-proof symbols, shell protection level and temperature group adaptability: explosion-proof symbols, shell protection level and temperature group of lamps and lanterns should be adapted to the explosion-hazardous environment. When the design does not require, the type of lamps and lanterns and explosion-proof structure of the selection should be [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_uag_custom_page_level_css":"","site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[7],"tags":[],"class_list":["post-2108","post","type-post","status-publish","format-standard","hentry","category-light"],"uagb_featured_image_src":{"full":false,"thumbnail":false,"medium":false,"medium_large":false,"large":false,"1536x1536":false,"2048x2048":false,"trp-custom-language-flag":false},"uagb_author_info":{"display_name":"Joe","author_link":"https:\/\/led.amasly.com\/fr\/author\/jacklin\/"},"uagb_comment_info":0,"uagb_excerpt":"Explosion-proof lamps and lanterns installation specification 1. Explosion-proof symbols, shell protection level and temperature group adaptability: explosion-proof symbols, shell protection level and temperature group of lamps and lanterns should be adapted to the explosion-hazardous environment. When the design does not require, the type of lamps and lanterns and explosion-proof structure of the selection should be\u2026","_links":{"self":[{"href":"https:\/\/led.amasly.com\/fr\/wp-json\/wp\/v2\/posts\/2108","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/led.amasly.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/led.amasly.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/led.amasly.com\/fr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/led.amasly.com\/fr\/wp-json\/wp\/v2\/comments?post=2108"}],"version-history":[{"count":2,"href":"https:\/\/led.amasly.com\/fr\/wp-json\/wp\/v2\/posts\/2108\/revisions"}],"predecessor-version":[{"id":2337,"href":"https:\/\/led.amasly.com\/fr\/wp-json\/wp\/v2\/posts\/2108\/revisions\/2337"}],"wp:attachment":[{"href":"https:\/\/led.amasly.com\/fr\/wp-json\/wp\/v2\/media?parent=2108"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/led.amasly.com\/fr\/wp-json\/wp\/v2\/categories?post=2108"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/led.amasly.com\/fr\/wp-json\/wp\/v2\/tags?post=2108"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}