{"id":2075,"date":"2025-02-28T21:49:24","date_gmt":"2025-02-28T13:49:24","guid":{"rendered":"https:\/\/led.amasly.com\/?p=2075"},"modified":"2025-03-07T22:17:24","modified_gmt":"2025-03-07T14:17:24","slug":"normes-des-boites-de-distribution-antideflagrantes-et-problemes-dinstallation","status":"publish","type":"post","link":"https:\/\/led.amasly.com\/fr\/equipement-antideflagrant\/normes-des-boites-de-distribution-antideflagrantes-et-problemes-dinstallation\/","title":{"rendered":"Normes relatives aux coffrets de distribution antid\u00e9flagrants et probl\u00e8mes d'installation"},"content":{"rendered":"<h2 class=\"wp-block-heading\"><strong>P<\/strong><strong>r\u00e9am\u00e9nager<\/strong><strong><\/strong><\/h2>\n\n\n\n<p>Avec le d\u00e9veloppement continu de l'industrie, la possibilit\u00e9 d'utiliser des bo\u00eetes de distribution antid\u00e9flagrantes augmente \u00e9galement.<\/p>\n\n\n\n<p>Les bo\u00eetes de distribution antid\u00e9flagrantes sont principalement utilis\u00e9es dans les mines de charbon, les casernes de pompiers, les installations p\u00e9troli\u00e8res et p\u00e9trochimiques, le secteur textile et d'autres secteurs. <strong>lieux inflammables et explosifs<\/strong>. Ces endroits sont plus expos\u00e9s aux accidents de protection. C'est pourquoi, dans le choix de la bo\u00eete de distribution \u00e9lectrique, il convient d'accorder une plus grande attention \u00e0 la protection de l'\u00e9quipement.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Normes sp\u00e9cifiques pour les bo\u00eetes de distribution antid\u00e9flagrantes<\/strong><strong><\/strong><\/h2>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>I. Bo\u00eetes de distribution antid\u00e9flagrantes - normes g\u00e9n\u00e9rales<\/strong><strong><\/strong><\/h3>\n\n\n\n<p>Indicateurs technologiques de production de bo\u00eetes de distribution pour r\u00e9pondre aux sp\u00e9cifications et aux exigences de conception, et conform\u00e9ment aux dispositions des normes de mise en \u0153uvre du produit \u00e0 produire.<\/p>\n\n\n\n<p>Tous les composants et param\u00e8tres techniques doivent \u00eatre conformes aux exigences de conception de la norme nationale GB7251. La production d'\u00e9chantillons doit \u00eatre notifi\u00e9e \u00e0 l'unit\u00e9 de construction, \u00e0 la supervision, \u00e0 l'unit\u00e9 de construction et \u00e0 l'acceptation du personnel concern\u00e9 avant la production compl\u00e8te.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>II.<\/strong><strong>&nbsp;bo\u00eete de distribution antid\u00e9flagrante partie du corps de la bo\u00eete<\/strong><strong><\/strong><\/h3>\n\n\n\n<p>La bo\u00eete de distribution est en acier inoxydable (Baosteel 304 ou plus), la couleur est celle de l'acier inoxydable, l'\u00e9paisseur de la bo\u00eete n'est pas inf\u00e9rieure \u00e0 4,0 mm.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>III.<\/strong><strong>&nbsp;composants de la bo\u00eete antid\u00e9flagrante<\/strong><strong><\/strong><\/h3>\n\n\n\n<p>Les composants \u00e9lectriques dans la bo\u00eete\/armoire de distribution doivent \u00eatre conformes aux dispositions pertinentes et doivent conserver leur espace libre et leur ligne de fuite dans des conditions d'utilisation normales ; les conducteurs et les bornes sous tension expos\u00e9s dans la bo\u00eete, leur espace libre et leur ligne de fuite ou leur tension de r\u00e9sistance aux chocs doivent \u00eatre au moins conformes aux dispositions pertinentes des composants \u00e9lectriques qui leur sont directement raccord\u00e9s.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>VI.<\/strong><strong>&nbsp;ligne d'assemblage du groupe de bo\u00eetes de distribution antid\u00e9flagrantes<\/strong><strong><\/strong><\/h3>\n\n\n\n<p>Le c\u00e2blage utilise des pi\u00e8ces galvanis\u00e9es pour toutes les fixations, le c\u00e2blage secondaire doit utiliser du fil noir et ajouter une s\u00e9quence de bo\u00eetiers ; la bo\u00eete des instruments de mesure dans le conducteur doit \u00eatre bien \u00e9maill\u00e9e d'\u00e9tain ; le c\u00e2blage de la bo\u00eete de distribution en couches doit \u00eatre envisag\u00e9 comme une goulotte d'entr\u00e9e et de sortie.<\/p>\n\n\n\n<p>Les bornes des interrupteurs doivent correspondre \u00e0 la section des fils ; apr\u00e8s l'installation des composants, les fils doivent \u00eatre soigneusement dispos\u00e9s et attach\u00e9s en un faisceau avec du ruban de nylon pour \u00eatre fix\u00e9s derri\u00e8re la carte.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Tabous courants concernant l'utilisation des bo\u00eetes de d\u00e9rivation antid\u00e9flagrantes<\/strong><strong><\/strong><\/h2>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>I. Utilisation de mat\u00e9riaux en bois sans traitement ignifuge<\/strong><strong><\/strong><\/h3>\n\n\n\n<p><strong>Cons\u00e9quences<\/strong>En outre, la bo\u00eete (planche) en bois ne subit pas de traitement ignifuge, ce qui peut facilement provoquer un incendie et constitue un risque pour la s\u00e9curit\u00e9.<\/p>\n\n\n\n<p><strong>Mesures<\/strong>: Afin de garantir une utilisation s\u00fbre, <strong>les coffrets de distribution antid\u00e9flagrants sont <\/strong>requis <strong>ne doivent pas \u00eatre constitu\u00e9s de mat\u00e9riaux inflammables.<\/strong>&nbsp;M\u00eame dans les endroits secs et sans poussi\u00e8re, les bo\u00eetes de distribution antid\u00e9flagrantes en bois doivent \u00eatre ignifug\u00e9es avant d'\u00eatre utilis\u00e9es.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>II.<\/strong><strong>&nbsp;la bo\u00eete de distribution d'\u00e9lectricit\u00e9 dans le champ n'a pas fait l'inspection<\/strong><strong><\/strong><\/h3>\n\n\n\n<p><strong>Cons\u00e9quences<\/strong>La bo\u00eete de distribution antid\u00e9flagrante de l'\u00e9clairage sans inspection, apr\u00e8s l'installation, se trouve souvent au deuxi\u00e8me \u00e9tage sans boulons de mise \u00e0 la terre sp\u00e9ciaux, avec une petite section du fil de mise \u00e0 la terre de protection, il y a des appareils \u00e9lectriques qui peuvent \u00eatre ouverts la porte et le fil flexible en cuivre nu du cadre m\u00e9tallique n'est pas une connexion fiable, les fils et les appareils \u00e9lectriques ne sont pas connect\u00e9s \u00e0 un solide, il y a le ph\u00e9nom\u00e8ne d'anti-bouclage. Les vis et les \u00e9crous ne n\u00e9cessitent pas de pi\u00e8ces galvanis\u00e9es, et le diam\u00e8tre des fils ne r\u00e9pond pas aux exigences. Il n'y a pas d'\u00e9tiquetage par code couleur, ni d'armoire \u00e0 cartes ou de sch\u00e9mas de circuits \u00e9lectriques. La disposition et l'espacement des appareils \u00e9lectriques ne sont pas raisonnables, et les modifications du calendrier retard\u00e9 affecteront \u00e9galement la qualit\u00e9.<\/p>\n\n\n\n<p><strong>Mesures<\/strong>Les produits sur le terrain doivent \u00eatre en stricte conformit\u00e9 avec la conception, les normes et les standards des exigences de l'inspection et de l'acceptation, afin de confirmer que l'installation a \u00e9t\u00e9 effectu\u00e9e avec succ\u00e8s.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>III.<\/strong><strong>&nbsp;l'installation n'est pas solide l'\u00e9l\u00e9vation ne r\u00e9pond pas aux exigences<\/strong><strong><\/strong><\/h3>\n\n\n\n<p><strong>Cons\u00e9quence<\/strong>: L'\u00e9l\u00e9vation de l'installation du bo\u00eetier de distribution antid\u00e9flagrant pour l'\u00e9clairage (panneau) n'est pas conforme \u00e0 la r\u00e9glementation, l'installation n'est pas ferme et le bo\u00eetier n'est pas vertical. Lorsqu'il est install\u00e9 dans l'obscurit\u00e9, les bords du panneau ne sont pas proches du mur, ce qui affecte l'utilisation de la fonction, et la vue n'est pas bonne.<\/p>\n\n\n\n<div class=\"wp-block-uagb-image uagb-block-fddb0dde wp-block-uagb-image--layout-default wp-block-uagb-image--effect-static wp-block-uagb-image--align-none\"><figure class=\"wp-block-uagb-image__figure\"><img decoding=\"async\" srcset=\"https:\/\/led.amasly.com\/wp-content\/uploads\/2025\/02\/\u56fe\u72471.png 310w, https:\/\/led.amasly.com\/wp-content\/uploads\/2025\/02\/\u56fe\u72471-161x300.png 161w\" sizes=\"auto, (max-width: 480px) 150px\" src=\"https:\/\/led.amasly.com\/wp-content\/uploads\/2025\/02\/\u56fe\u72471.png\" alt=\"\" class=\"uag-image-2076\" width=\"310\" height=\"578\" title=\"\u56fe\u72471\" loading=\"lazy\" role=\"img\"><\/figure><\/div>\n\n\n\n<p><strong>Mesures<\/strong>: L'\u00e9l\u00e9vation doit \u00eatre conforme aux exigences de la conception. Lorsque la conception n'est pas sp\u00e9cifi\u00e9e, la hauteur du bord inf\u00e9rieur du bo\u00eetier de distribution antid\u00e9flagrant de l'\u00e9clairage par rapport au sol doit \u00eatre de 1,5 m, et la hauteur du bord inf\u00e9rieur du tableau de distribution de l'\u00e9clairage par rapport au sol doit \u00eatre de 1,8 m. Le bo\u00eetier de distribution de l'\u00e9clairage antid\u00e9flagrant (panneau) doit \u00eatre install\u00e9 de mani\u00e8re s\u00fbre, et l'\u00e9cart admissible de la perpendicularit\u00e9 de l'installation ne doit pas \u00eatre sup\u00e9rieur \u00e0 3 mm ; il ne doit pas y avoir d'espace autour du bo\u00eetier de distribution antid\u00e9flagrant lorsqu'il est install\u00e9 dans l'obscurit\u00e9, les bords du panneau doivent \u00eatre proches du mur, et les parties en contact du corps du bo\u00eetier avec les b\u00e2timents et les structures doivent \u00eatre recouvertes d'une peinture anticorrosion. Il convient d'appliquer une peinture anticorrosion.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>IV.<\/strong><strong>&nbsp;le d\u00e9sordre de la ligne de caisse n'est pas regroup\u00e9 dans une liasse<\/strong><strong><\/strong><\/h3>\n\n\n\n<p><strong>Cons\u00e9quences<\/strong>Le c\u00e2blage dans le bo\u00eetier de distribution antid\u00e9flagrant pour l'\u00e9clairage (tableau) est d\u00e9sordonn\u00e9, et le deuxi\u00e8me tableau du bo\u00eetier appuie sur l'ouverture du tuyau, ce qui affecte l'entr\u00e9e des fils dans le bo\u00eetier. Si l'on force les fils \u00e0 entrer, l'isolation des fils sera endommag\u00e9e au fil du temps, ce qui entra\u00eenera facilement un court-circuit. L'entretien s'en trouve g\u00ean\u00e9 et la vue affect\u00e9e.<\/p>\n\n\n\n<p><strong>Mesures<\/strong>Les \u00e9l\u00e9ments suivants doivent \u00eatre pris en compte lors de l'installation de la bo\u00eete de distribution antid\u00e9flagrante : les bo\u00eetes m\u00e9talliques utilis\u00e9es pour l'\u00e9clairage doivent \u00eatre trait\u00e9es contre la rouille et la corrosion ; les trous de sortie de la bo\u00eete ne peuvent pas \u00eatre ouverts par soudage, le tuyau doit \u00eatre prot\u00e9g\u00e9 avant les trous de la bo\u00eete m\u00e9tallique ; les lignes sont bien dispos\u00e9es, la position de la tuyauterie dans la bo\u00eete est raisonnablement arrang\u00e9e. Ne laissez pas le panneau du deuxi\u00e8me \u00e9tage trop serr\u00e9 \u00e0 la pression du tuyau. Les fils dans la bo\u00eete doivent \u00eatre pos\u00e9s en ligne droite autour de la bo\u00eete et proprement regroup\u00e9s en faisceaux.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>V. Pas de N, barre PE dans la bo\u00eete \u00e9lectrique<\/strong><strong><\/strong><\/h3>\n\n\n\n<p><strong>Cons\u00e9quence<\/strong>: Les barres N et PE ne sont pas plac\u00e9es dans la bo\u00eete de distribution antid\u00e9flagrante de l'\u00e9clairage, ce qui ne permet pas d'assurer la s\u00e9curit\u00e9 du fonctionnement de la ligne.<\/p>\n\n\n\n<div class=\"wp-block-uagb-image uagb-block-2f51ad4a wp-block-uagb-image--layout-default wp-block-uagb-image--effect-static wp-block-uagb-image--align-none\"><figure class=\"wp-block-uagb-image__figure\"><a class=\"\" href=\"https:\/\/led.amasly.com\/fr\/\" target=\"\" rel=\"noopener\"><img decoding=\"async\" srcset=\"https:\/\/led.amasly.com\/wp-content\/uploads\/2025\/02\/\u56fe\u72472.png 486w, https:\/\/led.amasly.com\/wp-content\/uploads\/2025\/02\/\u56fe\u72472-275x300.png 275w\" sizes=\"auto, (max-width: 480px) 150px\" src=\"https:\/\/led.amasly.com\/wp-content\/uploads\/2025\/02\/\u56fe\u72472.png\" alt=\"\" class=\"uag-image-2077\" width=\"486\" height=\"531\" title=\"\u56fe\u72472\" loading=\"lazy\" role=\"img\"><\/a><\/figure><\/div>\n\n\n\n<p><strong>Mesures<\/strong>: Les bo\u00eetes de distribution antid\u00e9flagrantes pour l'\u00e9clairage sont install\u00e9es dans le bus de la ligne z\u00e9ro (ligne N) et de la ligne de mise \u00e0 la terre (ligne PE), la ligne z\u00e9ro et la ligne de mise \u00e0 la terre doivent \u00eatre connect\u00e9es au bus, non \u00e9piss\u00e9es, et num\u00e9rot\u00e9es.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>VI. Fusibles \u00e0 vis mal c\u00e2bl\u00e9s install\u00e9s<\/strong><strong><\/strong><\/h3>\n\n\n\n<p><strong>Cons\u00e9quence<\/strong>: Le fusible \u00e0 vis install\u00e9 dans la bo\u00eete de distribution antid\u00e9flagrante de l'\u00e9clairage n'est pas connect\u00e9 correctement, et le cordon d'alimentation est connect\u00e9 \u00e0 la borne filet\u00e9e, ce qui affecte le remplacement du noyau du fusible. Un fonctionnement incorrect peut facilement entra\u00eener des accidents par \u00e9lectrocution.<\/p>\n\n\n\n<p><strong>Mesures<\/strong>: Pour garantir la s\u00e9curit\u00e9, la ligne d'alimentation du fusible \u00e0 vis install\u00e9 dans la bo\u00eete de distribution antid\u00e9flagrante de l'\u00e9clairage doit \u00eatre connect\u00e9e \u00e0 la borne du contact central, et la ligne de charge doit \u00eatre connect\u00e9e \u00e0 la borne filet\u00e9e.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>VII.<\/strong><strong>&nbsp;la ligne de protection n'est pas en place le diam\u00e8tre de la ligne n'est pas conforme aux exigences<\/strong><strong><\/strong><\/h3>\n\n\n\n<p><strong>Cons\u00e9quences<\/strong>La ligne de protection n'est pas dispos\u00e9e \u00e0 partir de la borne, mais par le cadre de la bo\u00eete en s\u00e9rie, le diam\u00e8tre du fil n'est pas r\u00e9gl\u00e9 conform\u00e9ment aux exigences, la tension de la porte de la bo\u00eete de distribution antid\u00e9flagrante d\u00e9passe la s\u00e9curit\u00e9 de l'appareil n'a pas de terre de protection, ce qui peut facilement entra\u00eener des accidents de s\u00e9curit\u00e9.<\/p>\n\n\n\n<div class=\"wp-block-uagb-image uagb-block-e20ecc1e wp-block-uagb-image--layout-default wp-block-uagb-image--effect-static wp-block-uagb-image--align-none\"><figure class=\"wp-block-uagb-image__figure\"><img decoding=\"async\" srcset=\"https:\/\/led.amasly.com\/wp-content\/uploads\/2025\/02\/\u56fe\u72473.png ,https:\/\/led.amasly.com\/wp-content\/uploads\/2025\/02\/\u56fe\u72473.png 780w, https:\/\/led.amasly.com\/wp-content\/uploads\/2025\/02\/\u56fe\u72473.png 360w\" sizes=\"auto, (max-width: 480px) 150px\" src=\"https:\/\/led.amasly.com\/wp-content\/uploads\/2025\/02\/\u56fe\u72473.png\" alt=\"\" class=\"uag-image-2078\" width=\"358\" height=\"336\" title=\"\u56fe\u72473\" loading=\"lazy\" role=\"img\"><\/figure><\/div>\n\n\n\n<p><strong>Mesures<\/strong>La section transversale du fil de terre de protection ne doit pas \u00eatre inf\u00e9rieure \u00e0 la section transversale entre l'alimentation \u00e9lectrique et le plus grand fil des appareils \u00e9lectriques, mais elle doit \u00e9galement \u00eatre s\u00e9lectionn\u00e9e conform\u00e9ment aux dispositions pertinentes ; la bo\u00eete de distribution antid\u00e9flagrante doit \u00eatre solidement et correctement mise \u00e0 la terre, <strong>il doit y avoir un dispositif de verrouillage<\/strong>; Les panneaux mobiles doivent \u00eatre reli\u00e9s \u00e0 la bonne structure m\u00e9tallique mise \u00e0 la terre avec un fil flexible en cuivre nu ; la section du fil de cuivre nu doit \u00e9galement \u00eatre choisie conform\u00e9ment aux dispositions ; une \u00e9paisseur de paroi inf\u00e9rieure \u00e0 2,5 mm ne doit pas \u00eatre utilis\u00e9e comme ligne de mise \u00e0 la terre transversale de la canalisation et les appareils \u00e9lectriques doivent prot\u00e9ger la ligne de mise \u00e0 la terre du point de contact de la pression.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>VIII. Le nom du circuit n'est pas indiqu\u00e9 sur le frein<\/strong><strong><\/strong><\/h3>\n\n\n\n<p><strong>Cons\u00e9quence<\/strong>: Le frein de la bo\u00eete de distribution antid\u00e9flagrante de l'\u00e9clairage n'est pas \u00e9tiquet\u00e9 avec le nom du circuit, ce qui entra\u00eene des inconv\u00e9nients pour l'utilisation et la maintenance.<\/p>\n\n\n\n<p><strong>Mesures<\/strong>: En g\u00e9n\u00e9ral, conform\u00e9ment aux exigences des codes et des normes, la porte du coffret de distribution antid\u00e9flagrant pour l'\u00e9clairage (tableau) <strong>doit \u00eatre accompagn\u00e9 d'un sch\u00e9ma du syst\u00e8me de circuit<\/strong>, Le nom du circuit doit \u00eatre indiqu\u00e9 sur le frein, en particulier lorsque le bo\u00eetier de distribution antid\u00e9flagrant de l'\u00e9clairage est aliment\u00e9 en courant alternatif, en courant continu ou \u00e0 diff\u00e9rents niveaux, il doit \u00eatre clairement \u00e9tiquet\u00e9.<\/p>","protected":false},"excerpt":{"rendered":"<p>Preamble With the continuous development of industry, the chance of using explosion-proof distribution boxes is also rising. Explosion-proof distribution boxes are mainly used in coal mines, fire stations, petroleum, petrochemical installations and textile and other flammable and explosive places. These places are more prone to protection accidents. So in the choice of power distribution box [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_uag_custom_page_level_css":"","site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[8],"tags":[],"class_list":["post-2075","post","type-post","status-publish","format-standard","hentry","category-explosion-proof-equipment"],"uagb_featured_image_src":{"full":false,"thumbnail":false,"medium":false,"medium_large":false,"large":false,"1536x1536":false,"2048x2048":false,"trp-custom-language-flag":false},"uagb_author_info":{"display_name":"Joe","author_link":"https:\/\/led.amasly.com\/fr\/author\/jacklin\/"},"uagb_comment_info":0,"uagb_excerpt":"Preamble With the continuous development of industry, the chance of using explosion-proof distribution boxes is also rising. Explosion-proof distribution boxes are mainly used in coal mines, fire stations, petroleum, petrochemical installations and textile and other flammable and explosive places. These places are more prone to protection accidents. So in the choice of power distribution box\u2026","_links":{"self":[{"href":"https:\/\/led.amasly.com\/fr\/wp-json\/wp\/v2\/posts\/2075","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/led.amasly.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/led.amasly.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/led.amasly.com\/fr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/led.amasly.com\/fr\/wp-json\/wp\/v2\/comments?post=2075"}],"version-history":[{"count":2,"href":"https:\/\/led.amasly.com\/fr\/wp-json\/wp\/v2\/posts\/2075\/revisions"}],"predecessor-version":[{"id":2346,"href":"https:\/\/led.amasly.com\/fr\/wp-json\/wp\/v2\/posts\/2075\/revisions\/2346"}],"wp:attachment":[{"href":"https:\/\/led.amasly.com\/fr\/wp-json\/wp\/v2\/media?parent=2075"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/led.amasly.com\/fr\/wp-json\/wp\/v2\/categories?post=2075"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/led.amasly.com\/fr\/wp-json\/wp\/v2\/tags?post=2075"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}