{"id":2108,"date":"2025-03-01T10:19:05","date_gmt":"2025-03-01T02:19:05","guid":{"rendered":"https:\/\/led.amasly.com\/?p=2108"},"modified":"2025-03-07T21:28:56","modified_gmt":"2025-03-07T13:28:56","slug":"especificaciones-de-instalacion-de-lamparas-y-linternas-antideflagrantes","status":"publish","type":"post","link":"https:\/\/led.amasly.com\/es\/luz\/especificaciones-de-instalacion-de-lamparas-y-linternas-antideflagrantes\/","title":{"rendered":"Especificaciones de instalaci\u00f3n de l\u00e1mparas y linternas antideflagrantes"},"content":{"rendered":"<h1 class=\"wp-block-heading has-text-align-center\"><strong>Especificaciones de instalaci\u00f3n de l\u00e1mparas y linternas antideflagrantes<\/strong><strong><\/strong><\/h1>\n\n\n\n<p class=\"wp-block-paragraph\">1. Los s\u00edmbolos a prueba de explosiones, el nivel de protecci\u00f3n del armaz\u00f3n y la adaptabilidad del grupo de temperatura: los s\u00edmbolos a prueba de explosiones, el nivel de protecci\u00f3n del armaz\u00f3n y el grupo de temperatura de las l\u00e1mparas y linternas deben adaptarse al entorno con riesgo de explosi\u00f3n. Cuando el dise\u00f1o no lo requiera, el tipo de l\u00e1mparas y linternas y la estructura a prueba de explosiones de la selecci\u00f3n deben estar en consonancia con las disposiciones.<\/p>\n\n\n\n<div class=\"wp-block-uagb-image uagb-block-5670ae3f wp-block-uagb-image--layout-default wp-block-uagb-image--effect-static wp-block-uagb-image--align-none\"><figure class=\"wp-block-uagb-image__figure\"><a class=\"\" href=\"https:\/\/led.amasly.com\/es\/productos\/\" target=\"\" rel=\"noopener\"><img decoding=\"async\" srcset=\"https:\/\/led.amasly.com\/wp-content\/uploads\/2025\/01\/LED-explosion-proof-linear-lights.png ,https:\/\/led.amasly.com\/wp-content\/uploads\/2025\/01\/LED-explosion-proof-linear-lights.png 780w, https:\/\/led.amasly.com\/wp-content\/uploads\/2025\/01\/LED-explosion-proof-linear-lights.png 360w\" sizes=\"auto, (max-width: 480px) 150px\" src=\"https:\/\/led.amasly.com\/wp-content\/uploads\/2025\/01\/LED-explosion-proof-linear-lights.png\" alt=\"\" class=\"uag-image-1676\" width=\"1004\" height=\"294\" title=\"Luces lineales LED antideflagrantes\" loading=\"lazy\" role=\"img\"><\/a><\/figure><\/div>\n\n\n\n<p class=\"wp-block-paragraph\">2. 2. El uso de accesorios de l\u00e1mparas y linternas: los accesorios de l\u00e1mparas y linternas deben ser completos, no se utilizar\u00e1n piezas no a prueba de explosiones en lugar de accesorios a prueba de explosiones, tales como rejilla met\u00e1lica, pantalla de l\u00e1mpara, caja de conexiones y as\u00ed sucesivamente.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">3. Selecci\u00f3n del lugar de instalaci\u00f3n: el lugar de instalaci\u00f3n de las l\u00e1mparas y linternas debe estar alejado de la fuente de liberaci\u00f3n, y no instale l\u00e1mparas y linternas sobre y debajo de los puertos de alivio de presi\u00f3n y puertos de descarga de varias tuber\u00edas. &nbsp; &nbsp;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">4. Requisitos de instalaci\u00f3n fija: l\u00e1mparas e interruptores instalados con firmeza y fiabilidad, l\u00e1mparas e interruptores y roscas de la caja de conexiones enganchar el n\u00famero de botones no menos de 5 hebillas, hilos lisos, intactos, sin corrosi\u00f3n, y en los hilos est\u00e1n recubiertos con grasa compuesta de energ\u00eda el\u00e9ctrica o la posici\u00f3n de montaje del interruptor de grasa conductora resistente a la oxidaci\u00f3n debe ser f\u00e1cil de operar, la altura desde el suelo no es inferior a 1,3 metros.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">5. Integridad del armaz\u00f3n: el armaz\u00f3n de las l\u00e1mparas y los interruptores est\u00e1 completo, sin da\u00f1os ni depresiones, ranuras, sin grietas en la pantalla, sin torsiones ni deformaciones de la rejilla met\u00e1lica, y la marca de protecci\u00f3n contra explosiones es clara.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">6. Estado de los pernos de fijaci\u00f3n y las arandelas de sellado: los pernos de fijaci\u00f3n de las l\u00e1mparas y los interruptores no est\u00e1n flojos ni corro\u00eddos, y las arandelas de sellado est\u00e1n intactas.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">7. conducto y l\u00e1mparas, conexi\u00f3n de la caja de conexiones: conducto y l\u00e1mparas a prueba de explosiones, conexi\u00f3n de la caja de conexiones debe ser apretado, sellado intacto; roscas deben participar en el n\u00famero de botones no menos de 5 hebillas, y deben ser recubiertos con \u00e9ster compuesto de energ\u00eda el\u00e9ctrica o \u00e9ster antioxidante conductor en las roscas.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">8. Ajuste de la instalaci\u00f3n inclinada: Cuando las l\u00e1mparas se instalan inclinadas, las posiciones relativas de las juntas y los tubos de acero deben ajustarse para garantizar que la placa de sombreado est\u00e9 directamente encima de la bombilla.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">9. Instalaci\u00f3n y mantenimiento de las medidas de seguridad: instalaci\u00f3n y mantenimiento de l\u00e1mparas y linternas, primero debe cortar la fuente de alimentaci\u00f3n; uso, la superficie de las l\u00e1mparas y linternas tienen un cierto grado de aumento de la temperatura es un fen\u00f3meno normal, el centro de las partes transparentes de la temperatura es m\u00e1s alta, no toque.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">10. Requisitos para la sustituci\u00f3n de las bombillas: al sustituir las bombillas, debe utilizarse el mismo tipo y potencia de bombillas; si se cambia el tipo o la potencia de las bombillas, debe sustituirse el balasto correspondiente.<\/p>","protected":false},"excerpt":{"rendered":"<p>Explosion-proof lamps and lanterns installation specification 1. Explosion-proof symbols, shell protection level and temperature group adaptability: explosion-proof symbols, shell protection level and temperature group of lamps and lanterns should be adapted to the explosion-hazardous environment. When the design does not require, the type of lamps and lanterns and explosion-proof structure of the selection should be [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_uag_custom_page_level_css":"","site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[7],"tags":[],"class_list":["post-2108","post","type-post","status-publish","format-standard","hentry","category-light"],"uagb_featured_image_src":{"full":false,"thumbnail":false,"medium":false,"medium_large":false,"large":false,"1536x1536":false,"2048x2048":false,"trp-custom-language-flag":false},"uagb_author_info":{"display_name":"Joe","author_link":"https:\/\/led.amasly.com\/es\/author\/jacklin\/"},"uagb_comment_info":0,"uagb_excerpt":"Explosion-proof lamps and lanterns installation specification 1. Explosion-proof symbols, shell protection level and temperature group adaptability: explosion-proof symbols, shell protection level and temperature group of lamps and lanterns should be adapted to the explosion-hazardous environment. When the design does not require, the type of lamps and lanterns and explosion-proof structure of the selection should be&hellip;","_links":{"self":[{"href":"https:\/\/led.amasly.com\/es\/wp-json\/wp\/v2\/posts\/2108","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/led.amasly.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/led.amasly.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/led.amasly.com\/es\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/led.amasly.com\/es\/wp-json\/wp\/v2\/comments?post=2108"}],"version-history":[{"count":2,"href":"https:\/\/led.amasly.com\/es\/wp-json\/wp\/v2\/posts\/2108\/revisions"}],"predecessor-version":[{"id":2337,"href":"https:\/\/led.amasly.com\/es\/wp-json\/wp\/v2\/posts\/2108\/revisions\/2337"}],"wp:attachment":[{"href":"https:\/\/led.amasly.com\/es\/wp-json\/wp\/v2\/media?parent=2108"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/led.amasly.com\/es\/wp-json\/wp\/v2\/categories?post=2108"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/led.amasly.com\/es\/wp-json\/wp\/v2\/tags?post=2108"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}