{"id":3206,"date":"2025-05-04T22:55:16","date_gmt":"2025-05-04T14:55:16","guid":{"rendered":"https:\/\/led.amasly.com\/?page_id=3206"},"modified":"2025-05-04T22:55:22","modified_gmt":"2025-05-04T14:55:22","slug":"requisitos-de-los-equipos-antideflagrantes-para-almacenes-de-productos-quimicos-peligrosos","status":"publish","type":"page","link":"https:\/\/led.amasly.com\/es\/conocimiento\/conocimientos-sobre-productos-antideflagrantes\/requisitos-de-los-equipos-antideflagrantes-para-almacenes-de-productos-quimicos-peligrosos\/","title":{"rendered":"Requisitos de los equipos a prueba de explosiones para almacenes de productos qu\u00edmicos peligrosos"},"content":{"rendered":"<div class=\"wp-block-uagb-container uagb-block-27bae773 alignfull uagb-is-root-container\"><div class=\"uagb-container-inner-blocks-wrap\"><\/div><\/div>\n\n\n\n<h1 class=\"wp-block-heading has-text-align-center\"><strong>Requisitos de los equipos a prueba de explosiones para almacenes de productos qu\u00edmicos peligrosos<\/strong><\/h1>\n\n\n\n<div class=\"wp-block-uagb-image uagb-block-6bbbfc1c wp-block-uagb-image--layout-default wp-block-uagb-image--effect-static wp-block-uagb-image--align-none\"><figure class=\"wp-block-uagb-image__figure\"><img decoding=\"async\" srcset=\"https:\/\/led.amasly.com\/wp-content\/uploads\/2025\/05\/Explosion-proof-equipment-installation-diagram-1024x698.png ,https:\/\/led.amasly.com\/wp-content\/uploads\/2025\/05\/Explosion-proof-equipment-installation-diagram.png 780w, https:\/\/led.amasly.com\/wp-content\/uploads\/2025\/05\/Explosion-proof-equipment-installation-diagram.png 360w\" sizes=\"auto, (max-width: 480px) 150px\" src=\"https:\/\/led.amasly.com\/wp-content\/uploads\/2025\/05\/Explosion-proof-equipment-installation-diagram-1024x698.png\" alt=\"\" class=\"uag-image-3209\" width=\"1079\" height=\"736\" title=\"Esquema de instalaci\u00f3n del equipo antideflagrante\" loading=\"lazy\" role=\"img\"><\/figure><\/div>\n\n\n\n<p>Los productos qu\u00edmicos peligrosos son sustancias altamente t\u00f3xicas con propiedades corrosivas, explosivas, combustibles u oxidantes que plantean riesgos significativos para la salud humana, las instalaciones y el medio ambiente. Debido a sus caracter\u00edsticas f\u00edsicas y qu\u00edmicas \u00fanicas, una manipulaci\u00f3n inadecuada, fugas o explosiones pueden liberar humos o gases t\u00f3xicos. Estas sustancias tambi\u00e9n pueden contaminar el aire, el agua y el suelo, causando da\u00f1os ecol\u00f3gicos a largo plazo. Adem\u00e1s, los contaminantes pueden entrar en el cuerpo humano a trav\u00e9s de la cadena alimentaria, lo que subraya la importancia cr\u00edtica de una gesti\u00f3n adecuada.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>\u00bfC\u00f3mo pueden las empresas garantizar una gesti\u00f3n segura de los almacenes de sustancias qu\u00edmicas peligrosas?<\/strong><\/h2>\n\n\n\n<p>Los almacenes de productos qu\u00edmicos peligrosos deben ser a prueba de explosiones y resistentes al fuego. A continuaci\u00f3n se detallan los requisitos espec\u00edficos para la gesti\u00f3n de la seguridad, las normas y las especificaciones de los equipos a prueba de explosiones para este tipo de instalaciones.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Normas de seguridad para almacenes de productos qu\u00edmicos peligrosos<\/strong><\/h2>\n\n\n\n<ol start=\"1\" class=\"wp-block-list\">\n<li><strong>Instalaciones a prueba de explosiones<\/strong>\n<ul class=\"wp-block-list\">\n<li>Los equipos el\u00e9ctricos, las l\u00edneas de distribuci\u00f3n de energ\u00eda y la maquinaria de manipulaci\u00f3n de los almacenes de productos qu\u00edmicos inflamables o explosivos deben ser a prueba de explosiones.<\/li>\n\n\n\n<li>Los conductos met\u00e1licos para el cableado el\u00e9ctrico deben fijarse firmemente con conexiones roscadas. Los conductos flexibles antideflagrantes pueden utilizarse en zonas que requieran curvas complejas.<\/li>\n<\/ul>\n<\/li>\n\n\n\n<li><strong>Protecci\u00f3n contra rayos y electricidad est\u00e1tica<\/strong>\n<ul class=\"wp-block-list\">\n<li>Deben instalarse dispositivos de descarga est\u00e1tica con toma de tierra en las entradas de los almacenes.<\/li>\n\n\n\n<li>Los ventiladores, las estanter\u00edas met\u00e1licas y otros equipos conductores deben tener una toma de tierra que disipe la electricidad est\u00e1tica.<\/li>\n\n\n\n<li>Los sistemas de protecci\u00f3n contra rayos (por ejemplo, pararrayos, bandas, redes) deben inspeccionarse anualmente.<\/li>\n<\/ul>\n<\/li>\n\n\n\n<li><strong>Sistemas de ventilaci\u00f3n<\/strong>\n<ul class=\"wp-block-list\">\n<li>Los almacenes de l\u00edquidos y gases inflamables deben disponer de sistemas de ventilaci\u00f3n de emergencia a prueba de explosiones.<\/li>\n\n\n\n<li>Los conductos de escape deben ser met\u00e1licos y dirigir las emisiones a lugares exteriores seguros.<\/li>\n<\/ul>\n<\/li>\n\n\n\n<li><strong>Medidas de contenci\u00f3n de vertidos<\/strong>\n<ul class=\"wp-block-list\">\n<li>Los l\u00edquidos (Clase A, B, C) requieren barreras de contenci\u00f3n, piscinas antifugas y suelos impermeables.<\/li>\n\n\n\n<li>Los materiales reactivos al agua deben almacenarse en entornos sellados y secos con controles de humedad.<\/li>\n<\/ul>\n<\/li>\n\n\n\n<li><strong>Sistemas de vigilancia y alarma<\/strong>\n<ul class=\"wp-block-list\">\n<li>Instale detectores de gases combustibles\/t\u00f3xicos a alturas acordes con la densidad del gas.<\/li>\n\n\n\n<li>Pruebe peri\u00f3dicamente las alarmas a trav\u00e9s de agencias certificadas y garantice la cobertura total de las zonas peligrosas.<\/li>\n<\/ul>\n<\/li>\n\n\n\n<li><strong>Equipos de extinci\u00f3n de incendios<\/strong>\n<ul class=\"wp-block-list\">\n<li>Es obligatorio disponer de extintores, bocas de incendios sin obst\u00e1culos, aspersores y salidas de humo.<\/li>\n\n\n\n<li>Los agentes de extinci\u00f3n de incendios deben coincidir con los productos qu\u00edmicos almacenados:\n<ul class=\"wp-block-list\">\n<li><strong>Gases inflamables\/oxidantes<\/strong>: Polvo seco, arena.<\/li>\n\n\n\n<li><strong>L\u00edquidos inflamables<\/strong>: Espuma, polvo seco, CO\u2082 (los l\u00edquidos solubles en agua requieren espuma resistente al alcohol).<\/li>\n\n\n\n<li><strong>S\u00f3lidos inflamables<\/strong>: Espuma, polvo seco, arena, CO\u2082 o agua nebulizada.<\/li>\n\n\n\n<li><strong>Sustancias autoinflamables<\/strong>: Agua, polvo seco, arena, CO\u2082.<\/li>\n\n\n\n<li><strong>Materiales reactivos al agua<\/strong>: Polvo seco, arena.<\/li>\n\n\n\n<li><strong>Oxidantes<\/strong>: Polvo seco, agua, CO\u2082.<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<\/li>\n<\/ol>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Especificaciones de los equipos a prueba de explosiones<\/strong><\/h2>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>1. Interruptores a prueba de explosiones<\/strong><\/h3>\n\n\n\n<div class=\"wp-block-uagb-image uagb-block-860e52aa wp-block-uagb-image--layout-default wp-block-uagb-image--effect-static wp-block-uagb-image--align-none\"><figure class=\"wp-block-uagb-image__figure\"><img decoding=\"async\" srcset=\"https:\/\/led.amasly.com\/wp-content\/uploads\/2025\/05\/Installation-of-explosion-proof-switches-825x1024.png ,https:\/\/led.amasly.com\/wp-content\/uploads\/2025\/05\/Installation-of-explosion-proof-switches.png 780w, https:\/\/led.amasly.com\/wp-content\/uploads\/2025\/05\/Installation-of-explosion-proof-switches.png 360w\" sizes=\"auto, (max-width: 480px) 150px\" src=\"https:\/\/led.amasly.com\/wp-content\/uploads\/2025\/05\/Installation-of-explosion-proof-switches-825x1024.png\" alt=\"\" class=\"uag-image-3207\" width=\"1080\" height=\"1340\" title=\"Instalaci\u00f3n de interruptores antideflagrantes\" loading=\"lazy\" role=\"img\"><\/figure><\/div>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Se proh\u00edben los interruptores o cajas de distribuci\u00f3n dom\u00e9sticos est\u00e1ndar.<\/li>\n\n\n\n<li><strong>Normas de seguridad<\/strong>:\n<ul class=\"wp-block-list\">\n<li>6.1.2.1.1: El tipo de equipo, la clase, el grupo, las condiciones ambientales y las marcas deben cumplir las especificaciones de dise\u00f1o.<\/li>\n\n\n\n<li><strong>Referencia est\u00e1ndar<\/strong>:\u00a0<em>C\u00f3digo de seguridad para la protecci\u00f3n el\u00e9ctrica contra explosiones en atm\u00f3sferas potencialmente explosivas<\/em>.<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>2. Cableado a prueba de explosiones<\/strong><\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Utilice conductos de acero galvanizado con conexiones roscadas (m\u00ednimo 5 roscas engranadas).<\/li>\n\n\n\n<li>Los conductos de PVC o remachados est\u00e1n prohibidos debido a su mala estanqueidad y escasa resistencia.<\/li>\n\n\n\n<li><strong>Tubos flexibles antideflagrantes<\/strong>:\n<ul class=\"wp-block-list\">\n<li>Conecte equipos antideflagrantes o curvas complejas.<\/li>\n\n\n\n<li>Caracter\u00edsticas: Extremos roscados de metal, capa exterior de caucho y malla de acero para la disipaci\u00f3n est\u00e1tica.<\/li>\n\n\n\n<li>Alternativas prohibidas: Tubos de pl\u00e1stico o recubiertos de cera.<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n\n\n\n<div class=\"wp-block-uagb-image uagb-block-9fdef51a wp-block-uagb-image--layout-default wp-block-uagb-image--effect-static wp-block-uagb-image--align-none\"><figure class=\"wp-block-uagb-image__figure\"><a class=\"\" href=\"https:\/\/led.amasly.com\/es\/productos\/\" target=\"\" rel=\"noopener\"><img decoding=\"async\" srcset=\"https:\/\/led.amasly.com\/wp-content\/uploads\/2025\/05\/Installation-of-Explosion-Proof-Flexible-Connecting-Pipe-1024x771.png ,https:\/\/led.amasly.com\/wp-content\/uploads\/2025\/05\/Installation-of-Explosion-Proof-Flexible-Connecting-Pipe.png 780w, https:\/\/led.amasly.com\/wp-content\/uploads\/2025\/05\/Installation-of-Explosion-Proof-Flexible-Connecting-Pipe.png 360w\" sizes=\"auto, (max-width: 480px) 150px\" src=\"https:\/\/led.amasly.com\/wp-content\/uploads\/2025\/05\/Installation-of-Explosion-Proof-Flexible-Connecting-Pipe-1024x771.png\" alt=\"\" class=\"uag-image-3208\" width=\"1080\" height=\"813\" title=\"Instalaci\u00f3n de tuber\u00edas de conexi\u00f3n flexibles a prueba de explosiones\" loading=\"lazy\" role=\"img\"><\/a><\/figure><\/div>\n\n\n\n<p><strong>Normas de seguridad<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Norma 1<\/strong>:\n<ul class=\"wp-block-list\">\n<li>5.4.3: Los conductos deben utilizar tubos de acero galvanizado con roscas recubiertas de plomo o fosfato.<\/li>\n\n\n\n<li><strong>Referencia est\u00e1ndar<\/strong>:\u00a0<em>C\u00f3digo para el dise\u00f1o de instalaciones el\u00e9ctricas en atm\u00f3sferas explosivas<\/em>.<\/li>\n<\/ul>\n<\/li>\n\n\n\n<li><strong>Norma 2<\/strong>:\n<ul class=\"wp-block-list\">\n<li>5.3.2: S\u00f3lo conexiones roscadas; prohibida la soldadura.<\/li>\n\n\n\n<li>5.3.6: Instale conductos flexibles en entradas de motores, uniones de equipos y juntas de dilataci\u00f3n del edificio.<\/li>\n\n\n\n<li><strong>Referencia est\u00e1ndar<\/strong>:\u00a0<em>C\u00f3digo de construcci\u00f3n y aceptaci\u00f3n para instalaciones el\u00e9ctricas en entornos con riesgo de explosi\u00f3n e incendio<\/em>.<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n\n\n\n<div class=\"wp-block-uagb-image uagb-block-41192b6b wp-block-uagb-image--layout-default wp-block-uagb-image--effect-static wp-block-uagb-image--align-none\"><figure class=\"wp-block-uagb-image__figure\"><img decoding=\"async\" srcset=\"https:\/\/led.amasly.com\/wp-content\/uploads\/2025\/05\/Explosion-proof-connecting-tube.png ,https:\/\/led.amasly.com\/wp-content\/uploads\/2025\/05\/Explosion-proof-connecting-tube.png 780w, https:\/\/led.amasly.com\/wp-content\/uploads\/2025\/05\/Explosion-proof-connecting-tube.png 360w\" sizes=\"auto, (max-width: 480px) 150px\" src=\"https:\/\/led.amasly.com\/wp-content\/uploads\/2025\/05\/Explosion-proof-connecting-tube.png\" alt=\"\" class=\"uag-image-3210\" width=\"843\" height=\"850\" title=\"Tubo de conexi\u00f3n antideflagrante\" loading=\"lazy\" role=\"img\"><\/figure><\/div>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>3. Cajas de conexiones a prueba de explosiones<\/strong><\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Se utiliza para conectar conductos a equipos. Debe llevar la certificaci\u00f3n \u201cEX\u201d.<\/li>\n\n\n\n<li>Los puertos no utilizados deben precintarse. Seleccione las cajas en funci\u00f3n de las necesidades del terminal (2 v\u00edas, 3 v\u00edas, etc.).<\/li>\n<\/ul>\n\n\n\n<p><strong>Normas de seguridad<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>5.2.1\/5.2.3.5: Los cables en zonas potencialmente explosivas deben conectarse a trav\u00e9s de cajas de conexiones antideflagrantes.<\/li>\n\n\n\n<li>5.3.8: Selle los puertos no utilizados con tapones roscados o tapas selladas a presi\u00f3n.<\/li>\n\n\n\n<li><a href=\"http:\/\/www.iecex-certs.com\/\" rel=\"nofollow noopener\" target=\"_blank\"><strong>Referencia est\u00e1ndar<\/strong>:\u00a0<em>C\u00f3digo de construcci\u00f3n y aceptaci\u00f3n para instalaciones el\u00e9ctricas en entornos con riesgo de explosi\u00f3n e incendio<\/em>.<\/a><\/li>\n<\/ul>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<p class=\"has-text-align-center\">Al adherirse a estas normas, las empresas pueden mitigar los riesgos, garantizar el cumplimiento de la normativa y proteger al personal, las infraestructuras y el medio ambiente de incidentes catastr\u00f3ficos.<\/p>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-c7d898dd alignfull uagb-is-root-container\"><div class=\"uagb-container-inner-blocks-wrap\"><\/div><\/div>\n\n\n\n<h2 class=\"wp-block-heading\">Productos relacionados<\/h2>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-66e4defc alignfull uagb-is-root-container\"><div class=\"uagb-container-inner-blocks-wrap\">\n<div class=\"wp-block-uagb-container uagb-block-a42945f9\">\n<div class=\"wp-block-uagb-image uagb-block-7296296b wp-block-uagb-image--layout-default wp-block-uagb-image--effect-static wp-block-uagb-image--align-none\"><figure class=\"wp-block-uagb-image__figure\"><a class=\"\" href=\"https:\/\/led.amasly.com\/es\/productos\/\" target=\"\" rel=\"noopener\"><img decoding=\"async\" srcset=\"https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/09\/Explosion-proof-high-bay-lights.png ,https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/09\/Explosion-proof-high-bay-lights.png 780w, https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/09\/Explosion-proof-high-bay-lights.png 360w\" sizes=\"auto, (max-width: 480px) 150px\" src=\"https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/09\/Explosion-proof-high-bay-lights.png\" alt=\"\" class=\"uag-image-1495\" width=\"300\" height=\"300\" title=\"Luces de gran altura a prueba de explosiones\" loading=\"lazy\" role=\"img\"><\/a><\/figure><\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-4d3efde5\">\n<div class=\"wp-block-uagb-image uagb-block-c9e90797 wp-block-uagb-image--layout-default wp-block-uagb-image--effect-static wp-block-uagb-image--align-none\"><figure class=\"wp-block-uagb-image__figure\"><a class=\"\" href=\"https:\/\/led.amasly.com\/es\/productos\/\" target=\"\" rel=\"noopener\"><img decoding=\"async\" srcset=\"https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/07\/LED-tri-proof-lights2.png ,https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/07\/LED-tri-proof-lights2.png 780w, https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/07\/LED-tri-proof-lights2.png 360w\" sizes=\"auto, (max-width: 480px) 150px\" src=\"https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/07\/LED-tri-proof-lights2.png\" alt=\"\" class=\"uag-image-1132\" width=\"300\" height=\"300\" title=\"Luces LED-tri-proof2\" loading=\"lazy\" role=\"img\"><\/a><\/figure><\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-11c2578b\">\n<div class=\"wp-block-uagb-image uagb-block-6e8883aa wp-block-uagb-image--layout-default wp-block-uagb-image--effect-static wp-block-uagb-image--align-none\"><figure class=\"wp-block-uagb-image__figure\"><a class=\"\" href=\"https:\/\/led.amasly.com\/es\/productos\/\" target=\"\" rel=\"noopener\"><img decoding=\"async\" srcset=\"https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/09\/LED-Explosion-Proof-Gas-Station-Light.png ,https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/09\/LED-Explosion-Proof-Gas-Station-Light.png 780w, https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/09\/LED-Explosion-Proof-Gas-Station-Light.png 360w\" sizes=\"auto, (max-width: 480px) 150px\" src=\"https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/09\/LED-Explosion-Proof-Gas-Station-Light.png\" alt=\"\" class=\"uag-image-1501\" width=\"300\" height=\"300\" title=\"L\u00e1mpara LED antideflagrante para gasolineras\" loading=\"lazy\" role=\"img\"><\/a><\/figure><\/div>\n<\/div>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-548945b5 alignfull uagb-is-root-container\"><div class=\"uagb-container-inner-blocks-wrap\">\n<div class=\"wp-block-uagb-container uagb-block-967755d5\">\n<h4 class=\"wp-block-heading has-text-align-center\"><a href=\"https:\/\/led.amasly.com\/es\/productos\/\">Luces LED antideflagrantes<\/a><\/h4>\n<\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-9bc52fc2\">\n<h4 class=\"wp-block-heading has-text-align-center\"><a href=\"https:\/\/led.amasly.com\/es\/productos\/\">Luces LED Tri-Proof<\/a><\/h4>\n<\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-8ffa0a23\">\n<h4 class=\"wp-block-heading has-text-align-center\"><a href=\"https:\/\/led.amasly.com\/es\/productos\/\">Luces de gasolinera a prueba de explosiones<\/a><\/h4>\n<\/div>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-29499fe0 alignfull uagb-is-root-container\"><div class=\"uagb-container-inner-blocks-wrap\">\n<div class=\"wp-block-uagb-container uagb-block-777ee1c7\">\n<div class=\"wp-block-uagb-image uagb-block-2e9a1851 wp-block-uagb-image--layout-default wp-block-uagb-image--effect-static wp-block-uagb-image--align-none\"><figure class=\"wp-block-uagb-image__figure\"><a class=\"\" href=\"https:\/\/led.amasly.com\/es\/productos\/\" target=\"\" rel=\"noopener\"><img decoding=\"async\" srcset=\"https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/10\/50W-100W-150W-200W-300W-LED-Flood-Light.jpg ,https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/10\/50W-100W-150W-200W-300W-LED-Flood-Light.jpg 780w, https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/10\/50W-100W-150W-200W-300W-LED-Flood-Light.jpg 360w\" sizes=\"auto, (max-width: 480px) 150px\" src=\"https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/10\/50W-100W-150W-200W-300W-LED-Flood-Light.jpg\" alt=\"\" class=\"uag-image-1526\" width=\"300\" height=\"300\" title=\"L\u00e1mpara de inundaci\u00f3n LED 50W 100W 150W 200W 300W\" loading=\"lazy\" role=\"img\"><\/a><\/figure><\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-af8c8683\">\n<div class=\"wp-block-uagb-image uagb-block-67947854 wp-block-uagb-image--layout-default wp-block-uagb-image--effect-static wp-block-uagb-image--align-none\"><figure class=\"wp-block-uagb-image__figure\"><a class=\"\" href=\"https:\/\/led.amasly.com\/es\/productos\/\" target=\"\" rel=\"noopener\"><img decoding=\"async\" srcset=\"https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/07\/led-tri-proof-light.png ,https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/07\/led-tri-proof-light.png 780w, https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/07\/led-tri-proof-light.png 360w\" sizes=\"auto, (max-width: 480px) 150px\" src=\"https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/07\/led-tri-proof-light.png\" alt=\"\" class=\"uag-image-1130\" width=\"300\" height=\"300\" title=\"luz led-tri-proof\" loading=\"lazy\" role=\"img\"><\/a><\/figure><\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-0fdfdd58\">\n<div class=\"wp-block-uagb-image uagb-block-1187d32d wp-block-uagb-image--layout-default wp-block-uagb-image--effect-static wp-block-uagb-image--align-none\"><figure class=\"wp-block-uagb-image__figure\"><a class=\"\" href=\"https:\/\/led.amasly.com\/es\/productos\/\" target=\"\" rel=\"noopener\"><img decoding=\"async\" srcset=\"https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/07\/LED-street-light.jpg ,https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/07\/LED-street-light.jpg 780w, https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/07\/LED-street-light.jpg 360w\" sizes=\"auto, (max-width: 480px) 150px\" src=\"https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/07\/LED-street-light.jpg\" alt=\"\" class=\"uag-image-1145\" width=\"300\" height=\"300\" title=\"Alumbrado p\u00fablico LED\" loading=\"lazy\" role=\"img\"><\/a><\/figure><\/div>\n<\/div>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-6a60882c alignfull uagb-is-root-container\"><div class=\"uagb-container-inner-blocks-wrap\">\n<div class=\"wp-block-uagb-container uagb-block-f1e91a35\">\n<h4 class=\"wp-block-heading has-text-align-center\"><a href=\"https:\/\/led.amasly.com\/es\/productos\/\">Proyectores LED<\/a><\/h4>\n<\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-165bfa58\">\n<h4 class=\"wp-block-heading has-text-align-center\"><a href=\"https:\/\/led.amasly.com\/es\/productos\/\">Tubos de luz LED trif\u00e1sicos<\/a><\/h4>\n<\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-f6096e3b\">\n<h4 class=\"wp-block-heading has-text-align-center\"><a href=\"https:\/\/led.amasly.com\/es\/productos\/\">Alumbrado p\u00fablico LED<\/a><\/h4>\n<\/div>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-99c0e0a5 alignfull uagb-is-root-container\"><div class=\"uagb-container-inner-blocks-wrap\"><\/div><\/div>\n\n\n\n<p><\/p>","protected":false},"excerpt":{"rendered":"<p>Explosion-Proof Equipment Requirements for Hazardous Chemical Warehouses Hazardous chemicals refer to highly toxic substances with corrosive, explosive, combustible, or oxidizing properties that pose significant risks to human health, facilities, and the environment. Due to their unique physical and chemical characteristics, improper handling, leaks, or explosions can release toxic fumes or gases. These substances may also [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":2374,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_uag_custom_page_level_css":"","site-sidebar-layout":"no-sidebar","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"disabled","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"enabled","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"class_list":["post-3206","page","type-page","status-publish","hentry"],"uagb_featured_image_src":{"full":false,"thumbnail":false,"medium":false,"medium_large":false,"large":false,"1536x1536":false,"2048x2048":false,"trp-custom-language-flag":false},"uagb_author_info":{"display_name":"Joe","author_link":"https:\/\/led.amasly.com\/es\/author\/jacklin\/"},"uagb_comment_info":0,"uagb_excerpt":"Explosion-Proof Equipment Requirements for Hazardous Chemical Warehouses Hazardous chemicals refer to highly toxic substances with corrosive, explosive, combustible, or oxidizing properties that pose significant risks to human health, facilities, and the environment. Due to their unique physical and chemical characteristics, improper handling, leaks, or explosions can release toxic fumes or gases. These substances may also&hellip;","_links":{"self":[{"href":"https:\/\/led.amasly.com\/es\/wp-json\/wp\/v2\/pages\/3206","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/led.amasly.com\/es\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/led.amasly.com\/es\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/led.amasly.com\/es\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/led.amasly.com\/es\/wp-json\/wp\/v2\/comments?post=3206"}],"version-history":[{"count":1,"href":"https:\/\/led.amasly.com\/es\/wp-json\/wp\/v2\/pages\/3206\/revisions"}],"predecessor-version":[{"id":3211,"href":"https:\/\/led.amasly.com\/es\/wp-json\/wp\/v2\/pages\/3206\/revisions\/3211"}],"up":[{"embeddable":true,"href":"https:\/\/led.amasly.com\/es\/wp-json\/wp\/v2\/pages\/2374"}],"wp:attachment":[{"href":"https:\/\/led.amasly.com\/es\/wp-json\/wp\/v2\/media?parent=3206"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}