Anti explosion gas station light: constructing the core defense line of gas station safety φως

First, why Anti explosion gas station light into the gas station just need to configure

In the highest risk level of flammable and explosive commercial premises, gas stations are always on the list of key regulatory.

The U.S. Fire Protection Association statistics show that the world’s annual gas station accidents caused by electrical equipment, 32% directly related to the light system.

Explosion-proof gas station lights as special light equipment, its core value is reflected in:

Intrinsically safe explosion-proof design: approved explosion-proof shell structure [Ex d] and increased safety circuit care [Ex e].

Double protection, the internal probably produce sparks and external oil and gas environment completely isolated all-weather protection system: IP66/67 protection level to ensure that the storm wash or high-pressure water gun cleaning to maintain stable operation, -40 ° C to 55 ° C wide temperature range of adaptability to cover the global climate zones

Intelligent light control system: equipped with microwave sensor module Anti explosion gas station light can be implemented 30% -100% stepless dimming, automatically reduce the brightness at night when the traffic flow is reduced, the overall energy saving rate of 45%.

Δεύτερον, Anti explosion gas station light in the gas station areas of technical adaptation program

2.1 The main points of the φως configuration of the refueling operation area

The use of 120 ° wide-angle light distribution explosion-proof floodlights, to ensure that the 6-meter high pole to implement 25lux uniform illumination recommended 150W LED Anti explosion gas station light to replace the traditional 250W metal halide lamps, luminous efficacy up to 140lm / W lamp surface electrostatic spray treatment, effective resistance to gasoline, diesel and other chemical corrosion

2.2 Explosion-proof φως specification for oil storage tank areas

According to NFPA 30 specification requirements, 15-meter radius of the hazardous area must be used Class I, Division 1 certified lamps and lanterns configured with explosion-proof emergency light system, continuous power supply after a power failure ≥ 90 minutes Stainless steel explosion-proof maintenance lamps need to be equipped with mechanical interlocking devices to ensure that the cover is opened to ensure that the automatic power failure.

2.3 Convenience stores and ancillary areas φως strategy

3000K warm white explosion-proof downlight to create a comfortable shopping environment, color rendering index Ra>85 corridor area to install explosion-proof LED flat panel lights, thickness <30mm to implement the visual expansion of space integration of fire emergency function explosion-proof sign lamps, evacuation channel illumination to maintain more than 1 lux

Third, intelligent anti explosion gas station φως technology evolution direction

3.1 Digital control system upgrade

DALI2.0 protocol to implement single-lamp level control, with the oil station SCADA system to implement the light linkage fault self-diagnosis function can be real-time monitoring of the LED light source, drive power supply and other module status 4G / WiFi dual-mode communication to help remote firmware upgrades, reduce the cost of late maintenance

3.2 New energy integration program

Photovoltaic integrated explosion-proof lights in the average daily sunshine 4 hours of the region can implement energy self-sufficiency supercapacitor energy storage technology to break through the temperature limitations of lithium batteries, applicable to the Middle East and other high-temperature environments wind-solar complementary system for remote gas stations to supply independent power supply to handle the program

3.3 Preventive maintenance system

According to the MTBF 100,000 hours design life laid spare parts inventory model vibration sensors to monitor the structural stability of the lamp body, early warning of mechanical failure such as loose bolts three years of maintenance-free design to significantly reduce the cost of the whole life cycle

Fourth, the choice of Anti explosion gas station light suppliers 7 evaluation dimensions

1. Certification system integrity: need to have ATEX, IECEx, UL844 and other international certification light

2. Learning design skills: supply IES documents to verify the rationality of the light distribution curve

3. Thermal management program: finned heat dissipation structure to ensure that the junction temperature <85 ° C.

4. Warranty terms: more than five years of warranty period to reflect the confidence of product quality.

5. Customized service: support for non-standard voltage [such as DC12V, 24V, 100V/347V].

6. Customized localization services: 2-hour emergency response mechanism to lay the situation

7. Engineering cases: in BP, Shell and other international oil companies supply records

Fifth. Industry Data Insight [2023-2028 Forecast].

Indicator20232028 ForecastCAGR
Global Explosion-Proof Luminaires Market Size$3.2B$5.1B9.8%
LED Penetration68%92%6.2
Intelligent control system share22%57%21
Asia-Pacific Market Share39%47%11.5%

(Source: MarketsandMarkets Industry Research Report)

Immediate action:

Visit Amasly light to get “Gas Station Explosion-proof light Design White Paper”, our engineer team can supply:

✓ Free on-site illuminance simulations

✓ Station-wide explosion-proof rating assessment

✓ 5-year TCO cost analysis

Σχετικά προϊόντα

Αποκτήστε 30% από την πρώτη σας αγορά

X
elEL