{"id":1577,"date":"2024-12-27T20:51:33","date_gmt":"2024-12-27T12:51:33","guid":{"rendered":"https:\/\/led.amasly.com\/?p=1577"},"modified":"2024-12-28T14:52:43","modified_gmt":"2024-12-28T06:52:43","slug":"requirements-for-the-non-metallic-enclosures-and-non-metallic-parts-of-enclosures-in-explosion-proof-lamps-and-explosion-proof-equipment-for-the-attached-external-conductive-parts","status":"publish","type":"post","link":"https:\/\/led.amasly.com\/de\/explosion-proof-equipment\/requirements-for-the-non-metallic-enclosures-and-non-metallic-parts-of-enclosures-in-explosion-proof-lamps-and-explosion-proof-equipment-for-the-attached-external-conductive-parts\/","title":{"rendered":"Anforderungen an nicht-metallische Geh\u00e4use und nicht-metallische Teile von Geh\u00e4usen in explosionsgesch\u00fctzten Lampen und explosionsgesch\u00fctzten Ger\u00e4ten f\u00fcr die angebrachten \u00e4u\u00dferen leitenden Teile"},"content":{"rendered":"<p class=\"has-medium-font-size\">I. Bestimmungs- und Pr\u00fcfverfahren f\u00fcr am Ger\u00e4t angebrachte externe leitf\u00e4hige Teile <\/p>\n\n\n\n<p class=\"has-medium-font-size\">\u00c4u\u00dfere leitende Teile, die an einem nichtmetallischen Geh\u00e4use befestigt oder Teil eines solchen sind und einen Erdungswiderstand von mehr als 1 G\u03a9 haben, gemessen bei (500 \u00b1 25) V Gleichstrom, sowie Teile, die f\u00fcr statische Aufladungen anf\u00e4llig sind, die zu Z\u00fcndquellen werden k\u00f6nnen, wie z. B. Typenschilder usw. <\/p>\n\n\n\n<p class=\"has-medium-font-size\">Die Kapazit\u00e4t solcher Bauteile ist nach den in den einschl\u00e4gigen Abschnitten angegebenen Pr\u00fcfverfahren zu bestimmen. <\/p>\n\n\n\n<div class=\"wp-block-uagb-image uagb-block-a4683018 wp-block-uagb-image--layout-default wp-block-uagb-image--effect-static wp-block-uagb-image--align-none\"><figure class=\"wp-block-uagb-image__figure\"><a class=\"\" href=\"https:\/\/led.amasly.com\/de\/news\/\" target=\"\" rel=\"noopener\"><img decoding=\"async\" srcset=\"https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/12\/3b6fca440f00cb85059daed3e317bf9a_1n.jpg ,https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/12\/3b6fca440f00cb85059daed3e317bf9a_1n.jpg 780w, https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/12\/3b6fca440f00cb85059daed3e317bf9a_1n.jpg 360w\" sizes=\"auto, (max-width: 480px) 150px\" src=\"https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/12\/3b6fca440f00cb85059daed3e317bf9a_1n.jpg\" alt=\"\" class=\"uag-image-1578\" width=\"873\" height=\"382\" title=\"3b6fca440f00cb85059daed3e317bf9a_1n\" loading=\"lazy\" role=\"img\"><\/a><\/figure><\/div>\n\n\n\n<p class=\"has-medium-font-size\">II. Anforderungen f\u00fcr andere Produkte als tragbare oder individuelle Produkte <\/p>\n\n\n\n<p class=\"has-medium-font-size\">\u00dcberschreitet die gemessene Kapazit\u00e4t eines leitf\u00e4higen Teils die in Tabelle 11 angegebenen Werte, so ist das Ger\u00e4t mit dem entsprechenden Symbol \u201cX\u201d zu kennzeichnen, und in den besonderen Verwendungsbedingungen ist der gemessene Kapazit\u00e4tswert anzugeben, damit der Benutzer die Anwendbarkeit in bestimmten Anwendungen bestimmen kann. \u00c4u\u00dfere leitf\u00e4hige Teile, die sich in einer Position befinden, in der eine Entladung auf sich n\u00e4hernde geerdete Objekte nicht zu erwarten ist, m\u00fcssen nicht gepr\u00fcft werden. <\/p>\n\n\n\n<p class=\"has-medium-font-size\">Hinweis: \u2460 Es wird allgemein angenommen, dass die Kapazit\u00e4t von ungeerdeten Metallbefestigungselementen, wie z. B. Deckelschrauben, 3 pF nicht \u00fcberschreitet. \u2461 F\u00fcr Ger\u00e4te der Klasse III, die f\u00fcr den Einsatz in Rohren bestimmt sind, in denen schnell bewegter Staub auftreten kann, wird eine niedrigere Kapazit\u00e4tsgrenze in Betracht gezogen.<\/p>","protected":false},"excerpt":{"rendered":"<p>I. Determination and Testing Methods for External Conductive Parts Attached to the Appliance External conductive parts that are attached to or form part of a non-metallic enclosure and have a ground resistance exceeding 1 G\u03a9 when measured at (500 \u00b1 25) V d.c., and parts that are susceptible to static charges that may become ignition [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":1122,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_uag_custom_page_level_css":"","site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"disabled","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[8],"tags":[],"class_list":["post-1577","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-explosion-proof-equipment"],"uagb_featured_image_src":{"full":["https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/07\/Explosion-proof-linear-fluorescence-lights.png",300,300,false],"thumbnail":["https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/07\/Explosion-proof-linear-fluorescence-lights-150x150.png",150,150,true],"medium":["https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/07\/Explosion-proof-linear-fluorescence-lights.png",300,300,false],"medium_large":["https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/07\/Explosion-proof-linear-fluorescence-lights.png",300,300,false],"large":["https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/07\/Explosion-proof-linear-fluorescence-lights.png",300,300,false],"1536x1536":["https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/07\/Explosion-proof-linear-fluorescence-lights.png",300,300,false],"2048x2048":["https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/07\/Explosion-proof-linear-fluorescence-lights.png",300,300,false],"trp-custom-language-flag":["https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/07\/Explosion-proof-linear-fluorescence-lights.png",12,12,false]},"uagb_author_info":{"display_name":"Joe","author_link":"https:\/\/led.amasly.com\/de\/author\/jacklin\/"},"uagb_comment_info":0,"uagb_excerpt":"I. Determination and Testing Methods for External Conductive Parts Attached to the Appliance External conductive parts that are attached to or form part of a non-metallic enclosure and have a ground resistance exceeding 1 G\u03a9 when measured at (500 \u00b1 25) V d.c., and parts that are susceptible to static charges that may become ignition&hellip;","_links":{"self":[{"href":"https:\/\/led.amasly.com\/de\/wp-json\/wp\/v2\/posts\/1577","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/led.amasly.com\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/led.amasly.com\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/led.amasly.com\/de\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/led.amasly.com\/de\/wp-json\/wp\/v2\/comments?post=1577"}],"version-history":[{"count":1,"href":"https:\/\/led.amasly.com\/de\/wp-json\/wp\/v2\/posts\/1577\/revisions"}],"predecessor-version":[{"id":1579,"href":"https:\/\/led.amasly.com\/de\/wp-json\/wp\/v2\/posts\/1577\/revisions\/1579"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/led.amasly.com\/de\/wp-json\/wp\/v2\/media\/1122"}],"wp:attachment":[{"href":"https:\/\/led.amasly.com\/de\/wp-json\/wp\/v2\/media?parent=1577"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/led.amasly.com\/de\/wp-json\/wp\/v2\/categories?post=1577"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/led.amasly.com\/de\/wp-json\/wp\/v2\/tags?post=1577"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}