{"id":1567,"date":"2024-12-26T22:55:25","date_gmt":"2024-12-26T14:55:25","guid":{"rendered":"https:\/\/led.amasly.com\/?p=1567"},"modified":"2024-12-28T14:53:07","modified_gmt":"2024-12-28T06:53:07","slug":"the-treatment-approaches-for-the-failure-of-explosion-proof-performance-of-explosion-proof-electrical-equipment","status":"publish","type":"post","link":"https:\/\/led.amasly.com\/de\/explosion-proof-equipment\/the-treatment-approaches-for-the-failure-of-explosion-proof-performance-of-explosion-proof-electrical-equipment\/","title":{"rendered":"Die Behandlungsans\u00e4tze f\u00fcr das Versagen der explosionssicheren Leistung von explosionsgesch\u00fctzten elektrischen Betriebsmitteln"},"content":{"rendered":"<p class=\"has-medium-font-size\">Die Einsatzumgebung explosionsgesch\u00fctzter elektrischer Betriebsmittel ist in der Regel stark korrosiv und rau. Die regelm\u00e4\u00dfige Wartung explosionsgesch\u00fctzter elektrischer Betriebsmittel ist eine entscheidende Aufgabe, um ihre dauerhafte und effektive explosionsgesch\u00fctzte Leistung zu gew\u00e4hrleisten. <\/p>\n\n\n\n<div class=\"wp-block-uagb-image uagb-block-d748ffbc wp-block-uagb-image--layout-default wp-block-uagb-image--effect-static wp-block-uagb-image--align-none\"><figure class=\"wp-block-uagb-image__figure\"><a class=\"\" href=\"https:\/\/led.amasly.com\/de\/\" target=\"\" rel=\"noopener\"><img decoding=\"async\" srcset=\"https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/12\/Amasly-Explosion-proof-light-1024x576.png ,https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/12\/Amasly-Explosion-proof-light.png 780w, https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/12\/Amasly-Explosion-proof-light.png 360w\" sizes=\"auto, (max-width: 480px) 150px\" src=\"https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/12\/Amasly-Explosion-proof-light-1024x576.png\" alt=\"\" class=\"uag-image-1568\" width=\"1080\" height=\"607\" title=\"Amasly Explosionsgesch\u00fctzte Leuchte\" loading=\"lazy\" role=\"img\"><\/a><\/figure><\/div>\n\n\n\n<p class=\"has-medium-font-size\">I. Wartung explosionsgesch\u00fctzter elektrischer Betriebsmittel Wenn bei der Wartung festgestellt wird, dass die explosionsgesch\u00fctzte Leistung explosionsgesch\u00fctzter elektrischer Betriebsmittel aufgrund von Sch\u00e4den durch \u00e4u\u00dfere Einwirkung, atmosph\u00e4rische Korrosion, chemische Korrosion, mechanische Abnutzung, nat\u00fcrliche Alterung und andere Gr\u00fcnde nachgelassen hat oder ausgefallen ist, ist eine Wartung erforderlich. Die Wartung explosionsgesch\u00fctzter elektrischer Betriebsmittel sollte in \u00dcbereinstimmung mit den entsprechenden Vorschriften durchgef\u00fchrt werden. Wenn der urspr\u00fcngliche explosionssichere Leistungsgrad nach der Wartung nicht wiederhergestellt werden kann, kann er auf der Grundlage der tats\u00e4chlichen technischen Leistung gem\u00e4\u00df den nachstehenden Grunds\u00e4tzen behandelt werden: <\/p>\n\n\n\n<p class=\"has-medium-font-size\">1. Verwenden Sie einen niedrigeren Explosionsschutzgrad. <\/p>\n\n\n\n<p class=\"has-medium-font-size\">2. Umstellung auf nicht-explosionsgesch\u00fctzte elektrische Betriebsmittel zur Verwendung. <\/p>\n\n\n\n<p class=\"has-medium-font-size\">II. Versagen der explosionsgesch\u00fctzten Leistung explosionsgesch\u00fctzter elektrischer Betriebsmittel Wenn bei der Wartung festgestellt wird, dass sich die Struktur und die Parameter explosionsgesch\u00fctzter elektrischer Betriebsmittel ge\u00e4ndert haben und sie nicht mehr der urspr\u00fcnglichen explosionsgesch\u00fctzten Bauart und Konstruktion entsprechen und nicht repariert werden k\u00f6nnen, wird dies als Versagen gewertet und sollte unverz\u00fcglich au\u00dfer Betrieb genommen und ersetzt werden. Zum Beispiel: <\/p>\n\n\n\n<p class=\"has-medium-font-size\">1. Das Geh\u00e4use eines explosionsgesch\u00fctzten elektrischen Betriebsmittels ist stark verformt und kann nicht repariert werden. <\/p>\n\n\n\n<p class=\"has-medium-font-size\">2. Die druckfeste Oberfl\u00e4che ist stark besch\u00e4digt und kann nicht repariert werden. <\/p>\n\n\n\n<p class=\"has-medium-font-size\">3. Der druckfeste Spalt \u00fcberschreitet die Norm und kann nicht repariert werden. <\/p>\n\n\n\n<p class=\"has-medium-font-size\">4. Das Geh\u00e4use explosionsgesch\u00fctzter elektrischer Betriebsmittel hat einen Riss und entspricht nicht mehr den Anforderungen des urspr\u00fcnglichen explosionsgesch\u00fctzten Typs.<\/p>\n\n\n\n<p><\/p>","protected":false},"excerpt":{"rendered":"<p>The usage environment of explosion-proof electrical equipment is typically highly corrosive and harsh. Regular maintenance of explosion-proof electrical equipment is a crucial task to guarantee its sustained and effective explosion-proof performance. I. Maintenance of Explosion-proof Electrical Equipment When it is discovered during maintenance that the explosion-proof performance of explosion-proof electrical equipment has deteriorated or failed [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":1568,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_uag_custom_page_level_css":"","site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"disabled","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[8],"tags":[],"class_list":["post-1567","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-explosion-proof-equipment"],"uagb_featured_image_src":{"full":["https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/12\/Amasly-Explosion-proof-light.png",1080,607,false],"thumbnail":["https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/12\/Amasly-Explosion-proof-light-150x150.png",150,150,true],"medium":["https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/12\/Amasly-Explosion-proof-light-300x169.png",300,169,true],"medium_large":["https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/12\/Amasly-Explosion-proof-light-768x432.png",768,432,true],"large":["https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/12\/Amasly-Explosion-proof-light-1024x576.png",1024,576,true],"1536x1536":["https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/12\/Amasly-Explosion-proof-light.png",1080,607,false],"2048x2048":["https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/12\/Amasly-Explosion-proof-light.png",1080,607,false],"trp-custom-language-flag":["https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/12\/Amasly-Explosion-proof-light.png",18,10,false]},"uagb_author_info":{"display_name":"Joe","author_link":"https:\/\/led.amasly.com\/de\/author\/jacklin\/"},"uagb_comment_info":0,"uagb_excerpt":"The usage environment of explosion-proof electrical equipment is typically highly corrosive and harsh. Regular maintenance of explosion-proof electrical equipment is a crucial task to guarantee its sustained and effective explosion-proof performance. I. Maintenance of Explosion-proof Electrical Equipment When it is discovered during maintenance that the explosion-proof performance of explosion-proof electrical equipment has deteriorated or failed&hellip;","_links":{"self":[{"href":"https:\/\/led.amasly.com\/de\/wp-json\/wp\/v2\/posts\/1567","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/led.amasly.com\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/led.amasly.com\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/led.amasly.com\/de\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/led.amasly.com\/de\/wp-json\/wp\/v2\/comments?post=1567"}],"version-history":[{"count":1,"href":"https:\/\/led.amasly.com\/de\/wp-json\/wp\/v2\/posts\/1567\/revisions"}],"predecessor-version":[{"id":1569,"href":"https:\/\/led.amasly.com\/de\/wp-json\/wp\/v2\/posts\/1567\/revisions\/1569"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/led.amasly.com\/de\/wp-json\/wp\/v2\/media\/1568"}],"wp:attachment":[{"href":"https:\/\/led.amasly.com\/de\/wp-json\/wp\/v2\/media?parent=1567"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/led.amasly.com\/de\/wp-json\/wp\/v2\/categories?post=1567"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/led.amasly.com\/de\/wp-json\/wp\/v2\/tags?post=1567"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}