{"id":2075,"date":"2025-02-28T21:49:24","date_gmt":"2025-02-28T13:49:24","guid":{"rendered":"https:\/\/led.amasly.com\/?p=2075"},"modified":"2025-03-07T22:17:24","modified_gmt":"2025-03-07T14:17:24","slug":"explosion-proof-distribution-box-standards-and-installation-issues","status":"publish","type":"post","link":"https:\/\/led.amasly.com\/da\/explosion-proof-equipment\/explosion-proof-distribution-box-standards-and-installation-issues\/","title":{"rendered":"Standarder for eksplosionssikre fordelingsbokse og installationsproblemer"},"content":{"rendered":"<h2 class=\"wp-block-heading\"><strong>P<\/strong><strong>reamble<\/strong><strong><\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Med den fortsatte udvikling af industrien stiger chancen for at bruge eksplosionssikre fordelingsbokse ogs\u00e5.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Eksplosionssikre fordelingsbokse bruges hovedsageligt i kulminer, brandstationer, olie, petrokemiske installationer og tekstil og andre... <strong>Brandfarlige og eksplosive steder<\/strong>. Disse steder er mere udsatte for beskyttelsesulykker. S\u00e5 i valget af str\u00f8mfordelingsboks skal du v\u00e6re mere opm\u00e6rksom p\u00e5 beskyttelsen af udstyret.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Specifikke standarder for eksplosionssikre fordelingsbokse<\/strong><strong><\/strong><\/h2>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>I. Generelle standarder for eksplosionssikre fordelingsbokse<\/strong><strong><\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Indikatorer for produktionsteknologi til distributionskasser for at opfylde specifikationerne og designkravene og i overensstemmelse med bestemmelserne i de produktimplementeringsstandarder, der skal produceres.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Alle komponenter og tekniske parametre skal overholde den nationale standard GB7251 designkrav, pr\u00f8veproduktion skal meddeles til konstruktionsenheden, tilsynet, konstruktionsenheden for det relevante personale accept f\u00f8r fuld produktion.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>II.<\/strong><strong>&nbsp;eksplosionssikker fordelingsboks boksens kropsdel<\/strong><strong><\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Distributionskasse vedtager kasse i rustfrit st\u00e5l (rustfrit st\u00e5lmateriale er Baosteel 304 eller derover), farven er rustfri st\u00e5lfarve, kassens tykkelse er ikke mindre end 4,0 mm.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>III.<\/strong><strong>&nbsp;eksplosionssikre bokskomponenter<\/strong><strong><\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Elektriske komponenter i fordelingsboksen\/skabet skal overholde de relevante bestemmelser og skal opretholde deres elektriske frigang og krybeafstand under normale brugsforhold; de udsatte str\u00f8mf\u00f8rende ledere og terminaler i boksen, deres elektriske frigang og krybeafstand eller slagfast sp\u00e6nding skal mindst v\u00e6re i overensstemmelse med de relevante bestemmelser for de elektriske komponenter, der er direkte forbundet med dem.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>VI.<\/strong><strong>&nbsp;Eksplosionssikker samleb\u00e5ndsgruppe til fordelingsbokse<\/strong><strong><\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Ledningsf\u00f8ring alle fastg\u00f8relseselementer bruges galvaniserede dele, den sekund\u00e6re ledningsf\u00f8ring skal bruge sort ledning og tilf\u00f8je husets r\u00e6kkef\u00f8lge; kasse med m\u00e5leinstrumenter i lederen skal v\u00e6re godt emaljeret tin; lagdelte distributionsboksledninger b\u00f8r overvejes trunking ind og ud.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Afbryderterminaler skal passe til ledningstv\u00e6rsnittet; ledninger efter komponentinstallation skal arrangeres p\u00e6nt og bindes i et bundt med nylontape, der skal fastg\u00f8res bag tavlen.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Eksplosionssikre fordelingsbokse bruger almindelige tabuer i processen<\/strong><strong><\/strong><\/h2>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>I. Brug af tr\u00e6materialer uden brandh\u00e6mmende behandling<\/strong><strong><\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Konsekvenser<\/strong>: belysning eksplosionssikker distributionskasse (bord), hvis den er lavet af tr\u00e6 p\u00e5 et fugtigt og st\u00f8vet sted, let at forme, l\u00e6kage; derudover g\u00e5r tr\u00e6kassen (bordet) ikke gennem den brandh\u00e6mmende behandling, let at for\u00e5rsage brand, er en sikkerhedsrisiko.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Foranstaltninger<\/strong>: For at sikre sikker brug, <strong>eksplosionssikre fordelingsbokse (tavler) til belysning er <\/strong>p\u00e5kr\u00e6vet <strong>m\u00e5 ikke v\u00e6re lavet af br\u00e6ndbare materialer.<\/strong>&nbsp;Selv p\u00e5 t\u00f8rre, st\u00f8vfrie steder skal eksplosionssikre fordelingsbokse (tavler) af tr\u00e6 flammeh\u00e6mmes f\u00f8r brug.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>II.<\/strong><strong>&nbsp;str\u00f8mfordelingsboksen i marken foretog ikke inspektionen<\/strong><strong><\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Konsekvenser<\/strong>: belysning eksplosionssikker fordelingsboks (bord) uden inspektion, efter installation, ofte fundet p\u00e5 sin anden sal uden specielle jordingsbolte, lille tv\u00e6rsnit af den beskyttende jordforbindelse, der er elektriske apparater, der kan \u00e5bnes d\u00f8r og bar kobber fleksibel ledning af metalrammen er ikke en p\u00e5lidelig forbindelse, ledninger og elektriske apparater er ikke forbundet med en solid, der er f\u00e6nomenet anti-loop. Skruer og m\u00f8trikker kr\u00e6ver ikke galvaniserede dele, og ledningsdiameteren opfylder ikke kravene. Der er ingen farvekodet m\u00e6rkning og ingen kortskabe eller elektriske kredsl\u00f8bsdiagrammer. Layoutet og afstanden mellem de elektriske apparater er ikke rimelig, og \u00e6ndringer i den forsinkede tidsplan vil ogs\u00e5 p\u00e5virke kvaliteten.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Foranstaltninger<\/strong>: f\u00f8rst og fremmest i behandling af ordrer, til producenterne af tekniske krav i overensstemmelse med design og normer og standarder, producenter til at producere pr\u00f8ver, inspektion og reproduktion efter best\u00e5et; produkter i marken, b\u00f8r v\u00e6re i n\u00f8je overensstemmelse med design, normer og standarder for kravene til inspektion og accept, for at bekr\u00e6fte, at installationen efter best\u00e5et.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>III.<\/strong><strong>&nbsp;installationen er ikke solidt forh\u00f8jet opfylder ikke kravene<\/strong><strong><\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Konsekvenser<\/strong>: Installationsh\u00f8jden p\u00e5 den eksplosionssikre belysningsdistributionsboks (panel) overholder ikke reglerne, installationen er ikke fast, og boksen er ikke lodret. N\u00e5r det er installeret i m\u00f8rke, er kanterne omkring panelet ikke t\u00e6t p\u00e5 v\u00e6ggen, hvilket p\u00e5virker brugen af funktionen, og udsigten er ikke god.<\/p>\n\n\n\n<div class=\"wp-block-uagb-image uagb-block-fddb0dde wp-block-uagb-image--layout-default wp-block-uagb-image--effect-static wp-block-uagb-image--align-none\"><figure class=\"wp-block-uagb-image__figure\"><img decoding=\"async\" srcset=\"https:\/\/led.amasly.com\/wp-content\/uploads\/2025\/02\/\u56fe\u72471.png 310w, https:\/\/led.amasly.com\/wp-content\/uploads\/2025\/02\/\u56fe\u72471-161x300.png 161w\" sizes=\"auto, (max-width: 480px) 150px\" src=\"https:\/\/led.amasly.com\/wp-content\/uploads\/2025\/02\/\u56fe\u72471.png\" alt=\"\" class=\"uag-image-2076\" width=\"310\" height=\"578\" title=\"\u56fe\u72471\" loading=\"lazy\" role=\"img\"><\/figure><\/div>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Foranstaltninger<\/strong>: H\u00f8jden skal opfylde designkravene. N\u00e5r designet ikke er specificeret, skal h\u00f8jden p\u00e5 den nederste kant af den eksplosionssikre belysningsfordelingsboks fra jorden v\u00e6re 1,5 m, og h\u00f8jden p\u00e5 den nederste kant af belysningsfordelingsbr\u00e6ttet fra jorden skal v\u00e6re 1,8 m. Den eksplosionssikre belysningsdistributionsboks (bord) skal installeres sikkert, og den tilladte afvigelse af installationens vinkelrethed b\u00f8r ikke v\u00e6re mere end 3 mm, og der b\u00f8r ikke v\u00e6re nogen huller omkring den eksplosionssikre distributionsboks, n\u00e5r den er installeret i m\u00f8rket, panelkanterne omkring panelet skal v\u00e6re t\u00e6t p\u00e5 v\u00e6ggen, og kontaktdelene af boksekroppen og bygningerne og strukturerne skal v\u00e6re belagt med korrosionsbeskyttende maling. Anti-korrosionsmaling b\u00f8r anvendes.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>IV.<\/strong><strong>&nbsp;Box line cross messy ikke samlet i et bundt<\/strong><strong><\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Konsekvenser<\/strong>: Ledningerne i den eksplosionssikre fordelingsboks (tavle) til belysning er rodede, og den anden tavle i boksen presser mod r\u00f8r\u00e5bningen, hvilket p\u00e5virker ledningernes indf\u00f8ring i boksen. Hvis den tvinges til at klemme sig ind, vil ledningsisoleringen blive beskadiget over tid, hvilket let resulterer i en kortslutning. Og g\u00f8re vedligeholdelsen besv\u00e6rlig og p\u00e5virke udsigten.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Foranstaltninger<\/strong>: belysning eksplosionssikker distributionskasse ved hj\u00e6lp af metalkasser, b\u00f8r g\u00f8res for at forhindre rust og korrosionsbehandling; kasseudl\u00f8bshuller kan ikke \u00e5bnes med svejsning, et r\u00f8r et hul, gevindsk\u00e6ring skal beskyttes f\u00f8r metalkassehullerne; linjer er p\u00e6nt arrangeret, i kassen er r\u00f8rpositionen rimeligt arrangeret. Lad ikke anden sal bord til r\u00f8rtrykket for stramt. Ledningerne i kassen skal l\u00e6gges i en lige linje rundt om kassen og samles p\u00e6nt i bundter.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>V. Ingen N, PE-samleskinne i den elektriske boks<\/strong><strong><\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Konsekvenser<\/strong>: N- og PE-skinner er ikke anbragt i den eksplosionssikre fordelingsboks (tavle) til belysning, hvilket ikke kan sikre en sikker drift af linjen.<\/p>\n\n\n\n<div class=\"wp-block-uagb-image uagb-block-2f51ad4a wp-block-uagb-image--layout-default wp-block-uagb-image--effect-static wp-block-uagb-image--align-none\"><figure class=\"wp-block-uagb-image__figure\"><a class=\"\" href=\"https:\/\/led.amasly.com\/da\/\" target=\"\" rel=\"noopener\"><img decoding=\"async\" srcset=\"https:\/\/led.amasly.com\/wp-content\/uploads\/2025\/02\/\u56fe\u72472.png 486w, https:\/\/led.amasly.com\/wp-content\/uploads\/2025\/02\/\u56fe\u72472-275x300.png 275w\" sizes=\"auto, (max-width: 480px) 150px\" src=\"https:\/\/led.amasly.com\/wp-content\/uploads\/2025\/02\/\u56fe\u72472.png\" alt=\"\" class=\"uag-image-2077\" width=\"486\" height=\"531\" title=\"\u56fe\u72472\" loading=\"lazy\" role=\"img\"><\/a><\/figure><\/div>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Foranstaltninger<\/strong>: Belysningens eksplosionssikre fordelingsboks (tavle) er opsat i nullinjen (N-linjen) og beskyttelsesjordingslinjen (PE-linjen), nullinjen og beskyttelsesjordingslinjen skal forbindes til bussen, ikke splejses og nummereres.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>VI. Forkert tilsluttede skruesikringer installeret<\/strong><strong><\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Konsekvenser<\/strong>: Skruesikringen, der er installeret i den eksplosionssikre fordelingsboks (tavle) til belysning, er ikke tilsluttet korrekt, og netledningen er tilsluttet gevindterminalen, hvilket p\u00e5virker udskiftningen af sikringskernen. Og forkert betjening kan let f\u00f8re til ulykker med elektrisk st\u00f8d.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Foranstaltninger<\/strong>: For at sikre sikkerheden skal str\u00f8mledningen til skruesikringen, der er installeret i den eksplosionssikre fordelingsboks (tavle) til belysning, forbindes til terminalen p\u00e5 centerkontakten, og belastningsledningen skal forbindes til gevindterminalen.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>VII.<\/strong><strong>&nbsp;Beskyttelseslinjen er ikke p\u00e5 plads Linjens diameter opfylder ikke kravene<\/strong><strong><\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Konsekvenser<\/strong>: belysning eksplosionssikker distributionsboks (bord) beskyttelseslinje er ikke arrangeret fra terminalen, men af boksrammen i serie, ledningsdiameteren er ikke indstillet i henhold til kravene, eksplosionssikker distributionsboks d\u00f8rsp\u00e6nding over enhedens sikkerhed har ikke en beskyttende jord, let at forekomme sikkerhedsulykker.<\/p>\n\n\n\n<div class=\"wp-block-uagb-image uagb-block-e20ecc1e wp-block-uagb-image--layout-default wp-block-uagb-image--effect-static wp-block-uagb-image--align-none\"><figure class=\"wp-block-uagb-image__figure\"><img decoding=\"async\" srcset=\"https:\/\/led.amasly.com\/wp-content\/uploads\/2025\/02\/\u56fe\u72473.png ,https:\/\/led.amasly.com\/wp-content\/uploads\/2025\/02\/\u56fe\u72473.png 780w, https:\/\/led.amasly.com\/wp-content\/uploads\/2025\/02\/\u56fe\u72473.png 360w\" sizes=\"auto, (max-width: 480px) 150px\" src=\"https:\/\/led.amasly.com\/wp-content\/uploads\/2025\/02\/\u56fe\u72473.png\" alt=\"\" class=\"uag-image-2078\" width=\"358\" height=\"336\" title=\"\u56fe\u72473\" loading=\"lazy\" role=\"img\"><\/figure><\/div>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Foranstaltninger<\/strong>: i henhold til specifikationskravene skal belysningseksplosionssikker distributionsboks (bord) oprettes inden for den beskyttende jordbus, bus skal tilsluttes den beskyttende jord; tv\u00e6rsnitsarealet af den beskyttende jordledning b\u00f8r ikke v\u00e6re mindre end tv\u00e6rsnitsarealet fra str\u00f8mforsyningen til den st\u00f8rste ledning af de elektriske apparater; men det b\u00f8r ogs\u00e5 v\u00e6lges i overensstemmelse med de relevante bestemmelser; eksplosionssikker distributionsboks (bord) skal v\u00e6re fast og godt jordet, <strong>Der skal v\u00e6re en l\u00e5seanordning<\/strong>; 50V eller mere end \u00e5bningsd\u00f8ren til det elektriske udstyr, skal de bev\u00e6gelige paneler forbindes med den jordede gode metalramme med bar kobber fleksibel ledning p\u00e5lidelig forbindelse; bar kobbertr\u00e5ds tv\u00e6rsnitsareal b\u00f8r ogs\u00e5 v\u00e6lges i overensstemmelse med bestemmelserne; v\u00e6gtykkelse p\u00e5 mindre end 2,5 mm metalkasse og kasse, b\u00f8r ikke bruges som en r\u00f8rledning p\u00e5 tv\u00e6rs af jordforbindelse og elektriske apparater for at beskytte jordforbindelseslinjen i trykkontaktpunktet.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>VIII. Kredsl\u00f8bets navn er ikke m\u00e6rket p\u00e5 bremsen<\/strong><strong><\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Konsekvenser<\/strong>: Bremsen i den eksplosionssikre fordelingsboks (tavle) til belysning er ikke m\u00e6rket med kredsl\u00f8bets navn, hvilket medf\u00f8rer ulemper ved brug og vedligeholdelse.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Foranstaltninger<\/strong>: Generelt, i henhold til kravene i koder og standarder, er d\u00f8ren til den eksplosionssikre belysningsfordelingsboks (bord) <strong>skal v\u00e6re forsynet med et kredsl\u00f8bssystemdiagram<\/strong>, og navnet p\u00e5 kredsl\u00f8bet skal m\u00e6rkes p\u00e5 bremsen, is\u00e6r n\u00e5r der er vekselstr\u00f8m, j\u00e6vnstr\u00f8m eller forskellige niveauer af str\u00f8mforsyning i belysningens eksplosionssikre fordelingsboks (tavle), skal den m\u00e6rkes tydeligt.<\/p>","protected":false},"excerpt":{"rendered":"<p>Preamble With the continuous development of industry, the chance of using explosion-proof distribution boxes is also rising. Explosion-proof distribution boxes are mainly used in coal mines, fire stations, petroleum, petrochemical installations and textile and other flammable and explosive places. These places are more prone to protection accidents. So in the choice of power distribution box [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_uag_custom_page_level_css":"","_sitemap_exclude":false,"_sitemap_priority":"","_sitemap_frequency":"","site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[8],"tags":[],"class_list":["post-2075","post","type-post","status-publish","format-standard","hentry","category-explosion-proof-equipment"],"uagb_featured_image_src":{"full":false,"thumbnail":false,"medium":false,"medium_large":false,"large":false,"1536x1536":false,"2048x2048":false,"trp-custom-language-flag":false},"uagb_author_info":{"display_name":"Joe","author_link":"https:\/\/led.amasly.com\/da\/author\/jacklin\/"},"uagb_comment_info":0,"uagb_excerpt":"Preamble With the continuous development of industry, the chance of using explosion-proof distribution boxes is also rising. Explosion-proof distribution boxes are mainly used in coal mines, fire stations, petroleum, petrochemical installations and textile and other flammable and explosive places. These places are more prone to protection accidents. So in the choice of power distribution box&hellip;","_links":{"self":[{"href":"https:\/\/led.amasly.com\/da\/wp-json\/wp\/v2\/posts\/2075","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/led.amasly.com\/da\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/led.amasly.com\/da\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/led.amasly.com\/da\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/led.amasly.com\/da\/wp-json\/wp\/v2\/comments?post=2075"}],"version-history":[{"count":2,"href":"https:\/\/led.amasly.com\/da\/wp-json\/wp\/v2\/posts\/2075\/revisions"}],"predecessor-version":[{"id":2346,"href":"https:\/\/led.amasly.com\/da\/wp-json\/wp\/v2\/posts\/2075\/revisions\/2346"}],"wp:attachment":[{"href":"https:\/\/led.amasly.com\/da\/wp-json\/wp\/v2\/media?parent=2075"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/led.amasly.com\/da\/wp-json\/wp\/v2\/categories?post=2075"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/led.amasly.com\/da\/wp-json\/wp\/v2\/tags?post=2075"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}