{"id":2757,"date":"2025-03-28T22:24:06","date_gmt":"2025-03-28T14:24:06","guid":{"rendered":"https:\/\/led.amasly.com\/?page_id=2757"},"modified":"2026-01-25T22:32:11","modified_gmt":"2026-01-25T14:32:11","slug":"explosion-proof-emergency-exit-lights-in-automotive-plant-lighting-fundamental-role-and-safety-application-guide","status":"publish","type":"page","link":"https:\/\/led.amasly.com\/da\/knowledge\/explosion-proof-products-knowledge\/explosion-proof-emergency-exit-lights-in-automotive-plant-lighting-fundamental-role-and-safety-application-guide\/","title":{"rendered":"Eksplosionssikre n\u00f8dudgangslamper i bilindustrien Belysningens grundl\u00e6ggende rolle og vejledning i sikkerhedsanvendelse"},"content":{"rendered":"\n<div class=\"wp-block-uagb-container uagb-block-27bae773 alignfull uagb-is-root-container\"><div class=\"uagb-container-inner-blocks-wrap\"><\/div><\/div>\n\n\n\n<h1 class=\"wp-block-heading has-text-align-center\"><strong>Explosion proof emergency exit lights<\/strong><strong>&nbsp;in automotive plant lighting fundamental role and safety application guide<\/strong><strong><\/strong><\/h1>\n\n\n\n<div class=\"wp-block-uagb-image uagb-block-a669cb71 wp-block-uagb-image--layout-default wp-block-uagb-image--effect-static wp-block-uagb-image--align-none\"><figure class=\"wp-block-uagb-image__figure\"><img decoding=\"async\" srcset=\"https:\/\/led.amasly.com\/wp-content\/uploads\/2025\/03\/explosion-proof-emergency-lights-explosion-proof-exit-lights.png ,https:\/\/led.amasly.com\/wp-content\/uploads\/2025\/03\/explosion-proof-emergency-lights-explosion-proof-exit-lights.png 780w, https:\/\/led.amasly.com\/wp-content\/uploads\/2025\/03\/explosion-proof-emergency-lights-explosion-proof-exit-lights.png 360w\" sizes=\"auto, (max-width: 480px) 150px\" src=\"https:\/\/led.amasly.com\/wp-content\/uploads\/2025\/03\/explosion-proof-emergency-lights-explosion-proof-exit-lights.png\" alt=\"Emergency exit light explosion proof\uff0c Emergency lamp explosion proof, Ex proof emergency light, Ex proof exit light, Explosion proof battery light, Explosion proof emergency exit lights\" class=\"uag-image-2763\" width=\"691\" height=\"299\" title=\"explosion proof emergency lights explosion proof exit lights\" loading=\"lazy\" role=\"img\"\/><\/figure><\/div>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Introduction: automotive plant safety challenges and explosion<\/strong><strong>&nbsp;<\/strong><strong>proof emergency<\/strong><strong>&nbsp;exit<\/strong><strong>&nbsp;lights inevitable choice<\/strong><strong><\/strong><\/h2>\n\n\n\n<p>Automobile manufacturing plant as a highly complex industrial scenario, involving welding, painting, battery assembly and other high-risk processes, the presence of hydrogen, volatile organic compounds [VOCs], metal dust and other flammable and explosive substances.<\/p>\n\n\n\n<p>Ordinary lighting equipment in the high temperature, corrosive or flammable gas environment may cause serious accidents due to sparks or overheating.<\/p>\n\n\n\n<p>With its explosion-proof certification design, emergency power supply function and intelligent monitoring capability, the explosion-proof emergency indicator has become an indispensable safety and security equipment in the lighting system of automobile factories.<\/p>\n\n\n\n<p>This article will be from the risk prevention and control, application scenarios, selection guidelines and other dimensions, analysis of explosion-proof emergency lights for the automotive plant to build a full-process safety line of defense.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>First, the risk of explosion in automobile factories and explosion<\/strong><strong>&nbsp;<\/strong><strong>proof emergency<\/strong><strong>&nbsp;exit<\/strong><strong>&nbsp;lights core value<\/strong><strong><\/strong><\/h2>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>1. The primary safety hazards in automobile factories<\/strong><strong><\/strong><\/h3>\n\n\n\n<p>Combustible gases and dust: paint shop release VOCs [such as xylene, acetone] and air mixed with the lower limit of explosion as low as 1.1%.<\/p>\n\n\n\n<p>Battery assembly area hydrogen leakage [explosion limit 4%-75%] and welding workshop metal dust [such as aluminum powder explosion lower limit of 40g\/m\u00b3].<\/p>\n\n\n\n<p>High temperature and mechanical sparks: laser welding, stamping equipment operating at high temperatures or spattering sparks, probably igniting the surrounding combustible materials.<\/p>\n\n\n\n<p>Corrosive environment: electrophoretic coating line with high humidity and acidic and alkaline vapors accelerate the aging of ordinary lamps and lanterns.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>2. Explosion<\/strong><strong>&nbsp;<\/strong><strong>proof emergency<\/strong><strong>&nbsp;exit<\/strong><strong>&nbsp;lights safety protection mechanism<\/strong><strong><\/strong><\/h3>\n\n\n\n<p>Explosion proof emergency exit lights&nbsp;approved the following technology to implement intrinsic safety:<\/p>\n\n\n\n<p>Explosion-proof structure [Ex d] and safety-enhancing circuit [Ex e]: die-cast aluminum housing and multi-layer sealing to ensure that the internal arc or high temperature does not escape; circuit limit design in accordance with<a href=\"http:\/\/www.iecex-certs.com\/\" rel=\"nofollow noopener\" target=\"_blank\"> IEC 60079 <\/a>guidelines.<\/p>\n\n\n\n<p>Corrosion and impact resistance: IP66\/IP68 protection level housing with fluorocarbon spraying, resistant to acid and alkali corrosion and high-pressure water jet cleaning; impact resistance level IK10, resistant to mechanical collision.<\/p>\n\n\n\n<p>Dual power emergency switching: switch to lithium iron phosphate battery within 0.3 seconds after the interruption of the main power supply, supplying \u2265 180 minutes of continuous lighting [in line with EN 1838 guidelines].<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Second. <\/strong><strong>Explosion<\/strong><strong>&nbsp;<\/strong><strong>proof <\/strong><strong>emergency exit lights<\/strong><strong>&nbsp;in the automobile factory core application scenarios<\/strong><strong><\/strong><\/h2>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>1. Paint shop and paint line<\/strong><strong><\/strong><\/h3>\n\n\n\n<p>Equipment status monitoring: install explosion proof emergency exit lights next to the paint spraying robots and drying ovens, approving red\/green dual-color lights to provide real-time feedback on equipment failures [e.g. red light alarm for exceeding VOCs concentration].<\/p>\n\n\n\n<p>Emergency exhaust linkage: integrated gas detection module indicator, in the VOCs concentration \u2265 25% LEL triggered sound and light alarm and linkage exhaust system, synchronized start emergency lighting.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>2. Battery assembly and testing area<\/strong><strong><\/strong><\/h3>\n\n\n\n<p>Hydrogen leakage warning: deploy explosion-proof emergency lights around the fuel cell stack and hydrogen pipeline, activate high-frequency flashing and voice prompts when the hydrogen concentration is \u226510% LEL.<\/p>\n\n\n\n<p>Charging and discharging safety guidance: set up direction-indicating Explosion proof emergency exit lights&nbsp;in the area of charging and discharging test bench, with ground illumination \u22655lx in case of sudden power failure, and arrows guiding the safe evacuation paths.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>3. Welding workshop and assembly line<\/strong><strong><\/strong><\/h3>\n\n\n\n<p>Welding spark protection: Adopt explosion-proof grade Ex d IIC T4 indicator lamps with surface temperature \u2264135\u2103 to prevent splash sparks from igniting.<\/p>\n\n\n\n<p>AGV navigation marking: low-glare explosion proof emergency exit lights are installed in the automatic guided vehicle [AGV] channel to ensure that the path is clearly marked 24 hours a day to avoid collision accidents.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Third, the automotive plant explosion proof emergency\u00a0exit\u00a0lights selection and technical guidelines<\/strong><\/h2>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>1. Certification and compliance requirements<\/strong><strong><\/strong><\/h3>\n\n\n\n<p>International explosion-proof certification: must be approved ATEX [II 2G Ex d IIC T4 Gb], IECEx or China CNEx certification to adapt to Zone 1\/Zone 2 hazardous areas.<\/p>\n\n\n\n<p>Industry-specific guidelines: comply with ISO 9001 quality management system and IATF 16949 automotive industry-specific requirements.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>2. Fundamental technical parameters<\/strong><strong><\/strong><\/h3>\n\n\n\n<p>Light source performance: LED light source light efficiency \u2265 140lm \/ W, color temperature 5000K [neutral white], color rendering index Ra&gt; 85, accurate identification of wire harness color and assembly details.<\/p>\n\n\n\n<p>Emergency range capability: according to GB 51309-2018 guidelines, the evacuation channel needs to be equipped with an explosion-proof emergency indicator with a range of \u2265 180 minutes.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>3. Intelligent function upgrade<\/strong><strong><\/strong><\/h3>\n\n\n\n<p>Industrial IoT integration: Approve PROFINET or EtherCAT protocol to access the factory PLC system to implement real-time monitoring of lamp status and battery health.<\/p>\n\n\n\n<p>Adaptive dimming technology: built-in photosensitive sensors, according to the environmental lighting automatically adjust the brightness [such as 70% during the day, 100% at night], energy saving more than 30%.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Fourth, explosion proof emergency\u00a0exit\u00a0lights installation and maintenance specifications<\/strong><\/h2>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>1. Specialized installation requirements<\/strong><strong><\/strong><\/h3>\n\n\n\n<p>Explosion-proof electrical wiring: the use of flame retardant oil-resistant cable [such as CY type], the junction box adopts Ex e increased safety structure, grounding resistance \u2264 4\u03a9.<\/p>\n\n\n\n<p>Layout density improvement: according to the height of the workshop [often 5-8 meters], according to every 10-12 meters spacing installation, to ensure that the work surface level illumination \u2265 200lx.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>2. Full life cycle maintenance strategy<\/strong><strong><\/strong><\/h3>\n\n\n\n<p>Monthly inspection: Use anti-static tools to clean the oil on the surface of the lamp body, test the emergency switching response time [\u22640.5 seconds] and the battery capacity [recharge after discharging to 50%].<\/p>\n\n\n\n<p>Annual professional testing: commission a third-party organization to test the explosion-proof joint gap [\u22640.15mm], insulation resistance [\u22651000M\u03a9] and shell salt spray resistance [\u22651000 hours].<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Fifth<\/strong><strong>. Answers to common questions [FAQ<\/strong><strong><\/strong><\/h2>\n\n\n\n<p>Q1\uff1aWhat is the essential difference between explosion-proof emergency lights and ordinary lights?<\/p>\n\n\n\n<p>A: Explosion-proof emergency lights approved explosion-proof cavity and energy-limiting circuit design to ensure that the internal sparks do not ignite the external explosive environment, and built-in emergency power supply to meet the sudden power outages when the continuous lighting.<\/p>\n\n\n\n<p>Q2\uff1aDo all areas of the automobile factory need explosion-proof emergency lights?<\/p>\n\n\n\n<p>A: Paint shop, battery assembly area Zone 1\/Zone 2 hazardous areas must be used; office area and other non-hazardous areas can be configured with ordinary emergency lights, but need to be physically separated from the hazardous area.<\/p>\n\n\n\n<p>Q3\uff1aHow to cope with the damage of high pressure washing environment on lamps in automobile factory?<\/p>\n\n\n\n<p>A: Choose IP68 protection level, 316 stainless steel shell explosion-proof emergency lights, and regularly check the sealing ring elasticity [compression permanent deformation rate \u2264 20%].<\/p>\n\n\n\n<p>Q4\uff1aExplosion-proof emergency lights battery replacement cycle is how long?<\/p>\n\n\n\n<p>A: lithium iron phosphate battery cycle \u2265 2000 times [about 5-7 years], advocating the implementation of capacity testing every 2 years, below the nominal value of 80% replaced immediately.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Conclusion: explosion<\/strong><strong>&nbsp;<\/strong><strong>proof emergency<\/strong><strong>&nbsp;Exit<\/strong><strong>&nbsp;lights &#8211; automobile factory safety intelligence \u201clight guards\u201d<\/strong><strong><\/strong><\/h2>\n\n\n\n<p>In the automotive manufacturing industry, intelligent and safety guidelines for dual upgrade drive, explosion-proof emergency lights have evolved from a single lighting device to the core node of the factory safety ecosystem.<\/p>\n\n\n\n<p>Choosing Explosion proof emergency exit lights&nbsp;with intelligent monitoring, long life and full-scene adaptability can not only meet international norms such as IEC 60079, but also approve preventive maintenance to reduce the cost of the whole life cycle.<\/p>\n\n\n\n<p class=\"has-text-align-left\">In the future, along with the digital twin and AI predictive maintenance technology in-depth application, explosion-proof emergency lights will further enhance the energy efficiency of automobile factory safety management.<\/p>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-c7d898dd alignfull uagb-is-root-container\"><div class=\"uagb-container-inner-blocks-wrap\"><\/div><\/div>\n\n\n\n<h2 class=\"wp-block-heading\">Related Products<\/h2>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-66e4defc alignfull uagb-is-root-container\"><div class=\"uagb-container-inner-blocks-wrap\">\n<div class=\"wp-block-uagb-container uagb-block-a42945f9\">\n<div class=\"wp-block-uagb-image uagb-block-7296296b wp-block-uagb-image--layout-default wp-block-uagb-image--effect-static wp-block-uagb-image--align-none\"><figure class=\"wp-block-uagb-image__figure\"><a class=\"\" href=\"https:\/\/led.amasly.com\/products\/\" target=\"\" rel=\"noopener\"><img decoding=\"async\" srcset=\"https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/09\/Explosion-proof-high-bay-lights.png ,https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/09\/Explosion-proof-high-bay-lights.png 780w, https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/09\/Explosion-proof-high-bay-lights.png 360w\" sizes=\"auto, (max-width: 480px) 150px\" src=\"https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/09\/Explosion-proof-high-bay-lights.png\" alt=\"\" class=\"uag-image-1495\" width=\"300\" height=\"300\" title=\"Explosion proof high bay lights\" loading=\"lazy\" role=\"img\"><\/a><\/figure><\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-4d3efde5\">\n<div class=\"wp-block-uagb-image uagb-block-c9e90797 wp-block-uagb-image--layout-default wp-block-uagb-image--effect-static wp-block-uagb-image--align-none\"><figure class=\"wp-block-uagb-image__figure\"><a class=\"\" href=\"https:\/\/led.amasly.com\/products\/\" target=\"\" rel=\"noopener\"><img decoding=\"async\" srcset=\"https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/07\/LED-tri-proof-lights2.png ,https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/07\/LED-tri-proof-lights2.png 780w, https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/07\/LED-tri-proof-lights2.png 360w\" sizes=\"auto, (max-width: 480px) 150px\" src=\"https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/07\/LED-tri-proof-lights2.png\" alt=\"\" class=\"uag-image-1132\" width=\"300\" height=\"300\" title=\"LED-tri-proof-lights2\" loading=\"lazy\" role=\"img\"><\/a><\/figure><\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-11c2578b\">\n<div class=\"wp-block-uagb-image uagb-block-6e8883aa wp-block-uagb-image--layout-default wp-block-uagb-image--effect-static wp-block-uagb-image--align-none\"><figure class=\"wp-block-uagb-image__figure\"><a class=\"\" href=\"https:\/\/led.amasly.com\/products\/\" target=\"\" rel=\"noopener\"><img decoding=\"async\" srcset=\"https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/09\/LED-Explosion-Proof-Gas-Station-Light.png ,https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/09\/LED-Explosion-Proof-Gas-Station-Light.png 780w, https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/09\/LED-Explosion-Proof-Gas-Station-Light.png 360w\" sizes=\"auto, (max-width: 480px) 150px\" src=\"https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/09\/LED-Explosion-Proof-Gas-Station-Light.png\" alt=\"\" class=\"uag-image-1501\" width=\"300\" height=\"300\" title=\"LED Explosion Proof Gas Station Light\" loading=\"lazy\" role=\"img\"><\/a><\/figure><\/div>\n<\/div>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-548945b5 alignfull uagb-is-root-container\"><div class=\"uagb-container-inner-blocks-wrap\">\n<div class=\"wp-block-uagb-container uagb-block-967755d5\">\n<h4 class=\"wp-block-heading has-text-align-center\"><a href=\"https:\/\/led.amasly.com\/products\/\">LED Explosion Proof Lights<\/a><\/h4>\n<\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-9bc52fc2\">\n<h4 class=\"wp-block-heading has-text-align-center\"><a href=\"https:\/\/led.amasly.com\/products\/\">LED Tri-Proof Lights<\/a><\/h4>\n<\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-8ffa0a23\">\n<h4 class=\"wp-block-heading has-text-align-center\"><a href=\"https:\/\/led.amasly.com\/products\/\">Explosion Proof Gas Station Lights<\/a><\/h4>\n<\/div>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-29499fe0 alignfull uagb-is-root-container\"><div class=\"uagb-container-inner-blocks-wrap\">\n<div class=\"wp-block-uagb-container uagb-block-777ee1c7\">\n<div class=\"wp-block-uagb-image uagb-block-2e9a1851 wp-block-uagb-image--layout-default wp-block-uagb-image--effect-static wp-block-uagb-image--align-none\"><figure class=\"wp-block-uagb-image__figure\"><a class=\"\" href=\"https:\/\/led.amasly.com\/products\/\" target=\"\" rel=\"noopener\"><img decoding=\"async\" srcset=\"https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/10\/50W-100W-150W-200W-300W-LED-Flood-Light.jpg ,https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/10\/50W-100W-150W-200W-300W-LED-Flood-Light.jpg 780w, https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/10\/50W-100W-150W-200W-300W-LED-Flood-Light.jpg 360w\" sizes=\"auto, (max-width: 480px) 150px\" src=\"https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/10\/50W-100W-150W-200W-300W-LED-Flood-Light.jpg\" alt=\"\" class=\"uag-image-1526\" width=\"300\" height=\"300\" title=\"50W 100W 150W 200W 300W LED Flood Light\" loading=\"lazy\" role=\"img\"><\/a><\/figure><\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-af8c8683\">\n<div class=\"wp-block-uagb-image uagb-block-67947854 wp-block-uagb-image--layout-default wp-block-uagb-image--effect-static wp-block-uagb-image--align-none\"><figure class=\"wp-block-uagb-image__figure\"><a class=\"\" href=\"https:\/\/led.amasly.com\/products\/\" target=\"\" rel=\"noopener\"><img decoding=\"async\" srcset=\"https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/07\/led-tri-proof-light.png ,https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/07\/led-tri-proof-light.png 780w, https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/07\/led-tri-proof-light.png 360w\" sizes=\"auto, (max-width: 480px) 150px\" src=\"https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/07\/led-tri-proof-light.png\" alt=\"\" class=\"uag-image-1130\" width=\"300\" height=\"300\" title=\"led-tri-proof-light\" loading=\"lazy\" role=\"img\"><\/a><\/figure><\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-0fdfdd58\">\n<div class=\"wp-block-uagb-image uagb-block-1187d32d wp-block-uagb-image--layout-default wp-block-uagb-image--effect-static wp-block-uagb-image--align-none\"><figure class=\"wp-block-uagb-image__figure\"><a class=\"\" href=\"https:\/\/led.amasly.com\/products\/\" target=\"\" rel=\"noopener\"><img decoding=\"async\" srcset=\"https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/07\/LED-street-light.jpg ,https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/07\/LED-street-light.jpg 780w, https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/07\/LED-street-light.jpg 360w\" sizes=\"auto, (max-width: 480px) 150px\" src=\"https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/07\/LED-street-light.jpg\" alt=\"\" class=\"uag-image-1145\" width=\"300\" height=\"300\" title=\"LED-street-light\" loading=\"lazy\" role=\"img\"><\/a><\/figure><\/div>\n<\/div>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-6a60882c alignfull uagb-is-root-container\"><div class=\"uagb-container-inner-blocks-wrap\">\n<div class=\"wp-block-uagb-container uagb-block-f1e91a35\">\n<h4 class=\"wp-block-heading has-text-align-center\"><a href=\"https:\/\/led.amasly.com\/products\/\">LED Flood Lights<\/a><\/h4>\n<\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-165bfa58\">\n<h4 class=\"wp-block-heading has-text-align-center\"><a href=\"https:\/\/led.amasly.com\/products\/\">LED Tri-Proof Tube Lights<\/a><\/h4>\n<\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-f6096e3b\">\n<h4 class=\"wp-block-heading has-text-align-center\"><a href=\"https:\/\/led.amasly.com\/products\/\">LED Street Lights<\/a><\/h4>\n<\/div>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-99c0e0a5 alignfull uagb-is-root-container\"><div class=\"uagb-container-inner-blocks-wrap\"><\/div><\/div>\n\n\n\n<p><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Explosion proof emergency exit lights&nbsp;in automotive plant lighting fundamental role and safety application guide Introduction: automotive plant safety challenges and explosion&nbsp;proof emergency&nbsp;exit&nbsp;lights inevitable choice Automobile manufacturing plant as a highly complex industrial scenario, involving welding, painting, battery assembly and other high-risk processes, the presence of hydrogen, volatile organic compounds [VOCs], metal dust and other flammable [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":2374,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_uag_custom_page_level_css":"","site-sidebar-layout":"no-sidebar","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"disabled","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"enabled","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"class_list":["post-2757","page","type-page","status-publish","hentry"],"uagb_featured_image_src":{"full":false,"thumbnail":false,"medium":false,"medium_large":false,"large":false,"1536x1536":false,"2048x2048":false,"trp-custom-language-flag":false},"uagb_author_info":{"display_name":"Joe","author_link":"https:\/\/led.amasly.com\/da\/author\/jacklin\/"},"uagb_comment_info":0,"uagb_excerpt":"Explosion proof emergency exit lights&nbsp;in automotive plant lighting fundamental role and safety application guide Introduction: automotive plant safety challenges and explosion&nbsp;proof emergency&nbsp;exit&nbsp;lights inevitable choice Automobile manufacturing plant as a highly complex industrial scenario, involving welding, painting, battery assembly and other high-risk processes, the presence of hydrogen, volatile organic compounds [VOCs], metal dust and other flammable&hellip;","_links":{"self":[{"href":"https:\/\/led.amasly.com\/da\/wp-json\/wp\/v2\/pages\/2757","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/led.amasly.com\/da\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/led.amasly.com\/da\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/led.amasly.com\/da\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/led.amasly.com\/da\/wp-json\/wp\/v2\/comments?post=2757"}],"version-history":[{"count":2,"href":"https:\/\/led.amasly.com\/da\/wp-json\/wp\/v2\/pages\/2757\/revisions"}],"predecessor-version":[{"id":4811,"href":"https:\/\/led.amasly.com\/da\/wp-json\/wp\/v2\/pages\/2757\/revisions\/4811"}],"up":[{"embeddable":true,"href":"https:\/\/led.amasly.com\/da\/wp-json\/wp\/v2\/pages\/2374"}],"wp:attachment":[{"href":"https:\/\/led.amasly.com\/da\/wp-json\/wp\/v2\/media?parent=2757"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}