{"id":1555,"date":"2024-12-25T20:57:37","date_gmt":"2024-12-25T12:57:37","guid":{"rendered":"https:\/\/led.amasly.com\/?p=1555"},"modified":"2025-03-06T22:30:45","modified_gmt":"2025-03-06T14:30:45","slug":"maintenance-requirements-for-explosion-proof-electrical-equipment-explosion-proof-light","status":"publish","type":"post","link":"https:\/\/led.amasly.com\/cs\/explosion-proof-equipment\/maintenance-requirements-for-explosion-proof-electrical-equipment-explosion-proof-light\/","title":{"rendered":"Po\u017eadavky na \u00fadr\u017ebu nev\u00fdbu\u0161n\u00fdch elektrick\u00fdch za\u0159\u00edzen\u00ed Nev\u00fdbu\u0161n\u00e9 sv\u011btlo"},"content":{"rendered":"<h1 class=\"wp-block-heading\">Po\u017eadavky na \u00fadr\u017ebu nev\u00fdbu\u0161n\u00fdch elektrick\u00fdch za\u0159\u00edzen\u00ed Nev\u00fdbu\u0161n\u00e9 sv\u011btlo<\/h1>\n\n\n\n<p class=\"has-large-font-size wp-block-paragraph\"><strong>I. N\u00e1pravn\u00e1 opat\u0159en\u00ed a v\u00fdm\u011bna za\u0159\u00edzen\u00ed <\/strong><\/p>\n\n\n\n<p class=\"has-medium-font-size wp-block-paragraph\">Kontrola a \u00fadr\u017eba nev\u00fdbu\u0161n\u00fdch elektrick\u00fdch za\u0159\u00edzen\u00ed by m\u011bla v p\u0159\u00edpad\u011b pot\u0159eby zahrnovat proveden\u00ed vhodn\u00fdch n\u00e1pravn\u00fdch opat\u0159en\u00ed. D\u016fle\u017eit\u00e9 je zachovat celistvost nev\u00fdbu\u0161n\u00e9ho typu za\u0159\u00edzen\u00ed, co\u017e lze projednat s v\u00fdrobcem. V\u00fdm\u011bna sou\u010d\u00e1st\u00ed by m\u011bla b\u00fdt prov\u00e1d\u011bna v souladu s po\u017eadavky p\u0159\u00edslu\u0161n\u00fdch dokument\u016f. Pokud dokumenty stanov\u00ed, \u017ee v\u00fdm\u011bna ur\u010dit\u00fdch sou\u010d\u00e1st\u00ed m\u016f\u017ee m\u00edt nep\u0159\u00edzniv\u00fd vliv na bezpe\u010dnostn\u00ed vlastnosti za\u0159\u00edzen\u00ed, nem\u011bla by b\u00fdt takov\u00e1 v\u00fdm\u011bna provedena bez souhlasu p\u0159\u00edslu\u0161n\u00fdch org\u00e1n\u016f. Doporu\u010duje se vyvarovat se rozpor\u016f s opat\u0159en\u00edmi p\u0159ijat\u00fdmi v\u00fdrobcem ke sn\u00ed\u017een\u00ed vlivu statick\u00e9 elekt\u0159iny. P\u0159i v\u00fdm\u011bn\u011b sv\u011bteln\u00e9ho zdroje osv\u011btlovac\u00edho za\u0159\u00edzen\u00ed by m\u011bla b\u00fdt pou\u017eita spr\u00e1vn\u00e1 jmenovit\u00e1 hodnota a model sv\u011bteln\u00e9ho zdroje, jinak m\u016f\u017ee doj\u00edt k nadm\u011brn\u00e9 teplot\u011b. B\u011bhem \u017eivotnosti zv\u00fd\u0161en\u00e9ho bezpe\u010dnostn\u00edho typu sv\u011bteln\u00fdch zdroj\u016f je t\u0159eba v\u011bnovat pozornost pravideln\u00e9 v\u00fdm\u011bn\u011b sv\u011bteln\u00e9ho zdroje, proto\u017ee to m\u016f\u017ee ovlivnit teplotn\u00ed skupinu sv\u011bteln\u00fdch zdroj\u016f. Pozn\u00e1mka: Lept\u00e1n\u00ed, malov\u00e1n\u00ed nebo blokov\u00e1n\u00ed pr\u016fhledn\u00fdch \u010d\u00e1st\u00ed nebo nespr\u00e1vn\u00e1 instalace sv\u011bteln\u00e9ho za\u0159\u00edzen\u00ed mohou v\u00e9st k nadm\u011brn\u00e9 teplot\u011b. <\/p>\n\n\n\n<p class=\"has-large-font-size wp-block-paragraph\">II. \u00dadr\u017eba ohebn\u00fdch kabel\u016f <\/p>\n\n\n\n<p class=\"has-medium-font-size wp-block-paragraph\">Ohebn\u00e9 kabely, ohebn\u00e9 trubky a jejich koncov\u00e9 spoje jsou n\u00e1chyln\u00e9 k po\u0161kozen\u00ed a m\u011bly by b\u00fdt kontrolov\u00e1ny v p\u0159edepsan\u00fdch intervalech. Ka\u017ed\u00e9 zji\u0161t\u011bn\u00e9 po\u0161kozen\u00ed nebo nedostatek by m\u011bl b\u00fdt vym\u011bn\u011bn. <\/p>\n\n\n\n<p class=\"has-large-font-size wp-block-paragraph\">III. Odstran\u011bn\u00ed <\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Pokud je t\u0159eba b\u011bhem \u00fadr\u017eby ze za\u0159\u00edzen\u00ed vyjmout elektrick\u00e9 za\u0159\u00edzen\u00ed atd., m\u011bly by b\u00fdt obna\u017een\u00e9 vodi\u010de: a) \u0159\u00e1dn\u011b p\u0159ipojeny ke svork\u00e1m v p\u0159\u00edslu\u0161n\u00e9m krytu; nebo b) odpojeny od v\u0161ech zdroj\u016f nap\u00e1jen\u00ed a izolov\u00e1ny; nebo c) odpojeny od v\u0161ech zdroj\u016f nap\u00e1jen\u00ed a uzemn\u011bny. Pokud je elektrick\u00e9 za\u0159\u00edzen\u00ed trvale demontov\u00e1no, m\u011bly by b\u00fdt v\u0161echny s n\u00edm spojen\u00e9 nap\u00e1jec\u00ed vodi\u010de odpojeny a: a) vybour\u00e1ny; nebo b) spr\u00e1vn\u011b p\u0159ipojeny ke svork\u00e1m v p\u0159\u00edslu\u0161n\u00e9m krytu; nebo c) m\u011bl by b\u00fdt uzemn\u011bn pouze jeden konec a druh\u00fd konec kabelu by m\u011bl b\u00fdt izolov\u00e1n bezpe\u010dn\u00fdm zp\u016fsobem (nap\u0159\u00edklad smr\u0161\u0165ovac\u00ed f\u00f3li\u00ed). <\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Pozn\u00e1mka: Pou\u017eit\u00ed samotn\u00e9 samolepic\u00ed p\u00e1sky se nepova\u017euje za bezpe\u010dnou metodu izolace. <\/p>\n\n\n\n<p class=\"has-large-font-size wp-block-paragraph\">IV. Spojovac\u00ed materi\u00e1l a n\u00e1\u0159ad\u00ed <\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Pokud jsou vy\u017eadov\u00e1ny speci\u00e1ln\u00ed \u0161rouby, jin\u00fd spojovac\u00ed materi\u00e1l nebo speci\u00e1ln\u00ed n\u00e1\u0159ad\u00ed, m\u011bly by b\u00fdt tyto polo\u017eky dod\u00e1ny a pou\u017eity.<\/p>\n\n\n\n<div class=\"wp-block-uagb-image uagb-block-ca17c188 wp-block-uagb-image--layout-default wp-block-uagb-image--effect-static wp-block-uagb-image--align-none\"><figure class=\"wp-block-uagb-image__figure\"><a class=\"\" href=\"https:\/\/led.amasly.com\/cs\/\" target=\"\" rel=\"noopener\"><img decoding=\"async\" srcset=\"https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/08\/Explosion-proof-flood-light.png ,https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/08\/Explosion-proof-flood-light.png 780w, https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/08\/Explosion-proof-flood-light.png 360w\" sizes=\"auto, (max-width: 480px) 150px\" src=\"https:\/\/led.amasly.com\/wp-content\/uploads\/2024\/08\/Explosion-proof-flood-light.png\" alt=\"\" class=\"uag-image-1482\" width=\"300\" height=\"300\" title=\"Nev\u00fdbu\u0161n\u00e9 sv\u011btlo\" loading=\"lazy\" role=\"img\"><\/a><\/figure><\/div>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>","protected":false},"excerpt":{"rendered":"<p>Maintenance Requirements for Explosion-proof Electrical Equipment Explosion proof Light I. Remedial Measures and Equipment Replacement The inspection and maintenance of explosion-proof electrical devices should, when necessary, involve the implementation of appropriate remedial measures. It is important to maintain the integrity of the equipment&#8217;s explosion-proof type, which can be discussed with the manufacturer. Replacement of components [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_uag_custom_page_level_css":"","site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[8],"tags":[],"class_list":["post-1555","post","type-post","status-publish","format-standard","hentry","category-explosion-proof-equipment"],"uagb_featured_image_src":{"full":false,"thumbnail":false,"medium":false,"medium_large":false,"large":false,"1536x1536":false,"2048x2048":false,"trp-custom-language-flag":false},"uagb_author_info":{"display_name":"Joe","author_link":"https:\/\/led.amasly.com\/cs\/author\/jacklin\/"},"uagb_comment_info":0,"uagb_excerpt":"Maintenance Requirements for Explosion-proof Electrical Equipment Explosion proof Light I. Remedial Measures and Equipment Replacement The inspection and maintenance of explosion-proof electrical devices should, when necessary, involve the implementation of appropriate remedial measures. It is important to maintain the integrity of the equipment&#8217;s explosion-proof type, which can be discussed with the manufacturer. Replacement of components&hellip;","_links":{"self":[{"href":"https:\/\/led.amasly.com\/cs\/wp-json\/wp\/v2\/posts\/1555","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/led.amasly.com\/cs\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/led.amasly.com\/cs\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/led.amasly.com\/cs\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/led.amasly.com\/cs\/wp-json\/wp\/v2\/comments?post=1555"}],"version-history":[{"count":5,"href":"https:\/\/led.amasly.com\/cs\/wp-json\/wp\/v2\/posts\/1555\/revisions"}],"predecessor-version":[{"id":2283,"href":"https:\/\/led.amasly.com\/cs\/wp-json\/wp\/v2\/posts\/1555\/revisions\/2283"}],"wp:attachment":[{"href":"https:\/\/led.amasly.com\/cs\/wp-json\/wp\/v2\/media?parent=1555"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/led.amasly.com\/cs\/wp-json\/wp\/v2\/categories?post=1555"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/led.amasly.com\/cs\/wp-json\/wp\/v2\/tags?post=1555"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}